4.Install extension (102) to meter:

a.Loosen extension nut (102a) (FIG. 4) until it is completely off tube threads.

102

102a

FIG. 4

NOTE: Do not use PTFE tape or thread sealant on threads of extension (102). This could cause the fitting to leak.

b.Thread extension (102) into meter housing as shown in FIG. 5 until it bottoms out.

102

FIG. 5

c.Align extension (102) with meter housing and handle. Hand tighten extension nut (102a).

FIG. 6

Installation

d. Wrench tighten extension nut (102a).

5.Install nozzle (101):

NOTE: Do not use PTFE tape or thread sealant on threads of nozzle (101). This could cause the fitting to leak.

a.Thread nozzle (101) onto extension (102) as shown in FIG. 7.

.

102

101

101a

FIG. 7

b.Use an open-end adjustable wrench on flats of nozzle bushing (101a) (FIG. 7) to tighten fitting.

Only tighten nozzle with wrench on flats of the nozzle bushing.

Do not disassemble the bushing from noz- zle. Disassembly will affect performance of the nozzle.

333492B

11

Image 11
Contents List of Models Important Safety InstructionsModel Number Model Description Inlet ModelsSDMM8 Manual Bare Meters SDMM8 Manual Meters with Nozzle and Extension PackagesSDMP8 Preset Meters SDMP8 Preset Meters with Nozzle and Extension Packages Fire and Explosion Hazard Equipment Misuse Hazard Key Typical InstallationGrounding InstallationPressure Relief Procedure Component Identification Flushing Pre-Installation ProcedureInstallation Procedure Installing Meter FIGInstallation Manual Shutoff Valve Preset Automatic ShutoffOperation Problem Cause Solution TroubleshootingCleaning / Repairing the Fluid Section ServiceSDMM8 Manual Meter Counter Section Repair DisassemblyReassembly SDMP8 Preset Meter Counter Section Repair Remove the entire counter assembly 31 Models 24U959, 24U960, 24U961, 24U956, 24U957, 24U958 SDMM8 Manual Meter PartsDescription Qty SDMM8 Manual Meter Parts43a SDMP8 Preset Meter PartsSDMP8 Preset Meter Parts Needle Kit No Description Nozzle 101 and Extension 102 KitsDescription Qty Fluid Type Nozzle 101 PartsManual and Preset Meter Metric Technical DataManual Meter Preset Meter DimensionsGraco Information Graco Extended Meter Warranty