Graco 333492B Operation, Preset Automatic Shutoff, Manual Shutoff Valve

Page 12

Operation

Operation

NOTE: The letters used in the following instructions refer to Typical Installation on page 7 and the Compo- nent Identification on page 9. Numbers used in the fol- lowing instructions refer to the Parts List on pages 19 - 21.

1.Open fluid shut off valves (J and L).

2.Start pump (F) to pressurize system.

3.Adjust the air pressure to the pump motor so the fluid pressure is no greater than 1500 psi (103.4 bar, 10.34 MPa)

NOTE: To ensure dispensing accuracy, before begin- ning dispense, pull trigger to purge all air from the fluid lines and meter.

4.Continue operation with instructions for Preset Auto- matic or Manual Shutoff Valve Instructions.

SPLASH HAZARD

Do not trigger meter when nozzle is closed. Fluid will build up behind the nozzle. Fluid can leak from the nozzle and can unexpectedly be expelled when the nozzle is opened. If the meter is accidentally trig- gered with the nozzle closed, point the nozzle into a waste bucket and slowly open the nozzle to relieve pressure and expel the built up fluid.

Preset Automatic Shutoff

NOTE: Clean strainer (3a) regularly. See Parts, page 19.

NOTICE

To avoid costly meter damage, never turn the Preset meter pointer (41) (FIG. 8) backwards (clockwise).

41

FIG. 8

The totalizer keeps a running total of the amounts dis- pensed.

1.Turn meter pointer (41) counter-clockwise to select the desired volume.

2.Turn automatic twist lock nozzle (101) clockwise to open nozzle. Insert nozzle into the fluid receptacle and pull the trigger (12).

NOTE: The trigger latches automatically. Do not set trigger to enable meter to dispense when it is unat- tended.

The meter shuts off automatically when the set amount of fluid is dispensed.

Manual Shutoff Valve

NOTE: Clean strainer (3a) regularly. See Parts, page 21.

NOTICE

To avoid costly meter damage, never turn the Manual Meter pointer (41) backwards (clockwise).

41

FIG. 9

The totalizer keeps a running total of the amounts dis- pensed.

1.Turn automatic twist lock nozzle (101) counter- clockwise to open nozzle. Insert nozzle into the fluid receptacle and pull the trigger (12).

2.Watch the meter pointer (41) on the meter dial (37) move. Release the trigger (12) when the desired amount of fluid has been dispensed.

3.Turn the meter pointer (41) counter-clockwise to return it to “0” before dispensing again. See FIG. 9

12

333492B

Image 12
Contents Important Safety Instructions List of ModelsModels SDMM8 Manual Bare MetersSDMM8 Manual Meters with Nozzle and Extension Packages Model Number Model Description InletSDMP8 Preset Meters SDMP8 Preset Meters with Nozzle and Extension Packages Fire and Explosion Hazard Equipment Misuse Hazard Typical Installation KeyInstallation Pressure Relief ProcedureGrounding Component Identification Pre-Installation Procedure Installation ProcedureInstalling Meter FIG FlushingInstallation Preset Automatic Shutoff OperationManual Shutoff Valve Troubleshooting Problem Cause SolutionService Cleaning / Repairing the Fluid SectionDisassembly SDMM8 Manual Meter Counter Section RepairReassembly SDMP8 Preset Meter Counter Section Repair Remove the entire counter assembly 31 SDMM8 Manual Meter Parts Models 24U959, 24U960, 24U961, 24U956, 24U957, 24U958SDMM8 Manual Meter Parts Description QtySDMP8 Preset Meter Parts 43aSDMP8 Preset Meter Parts Needle Nozzle 101 and Extension 102 Kits Kit No DescriptionNozzle 101 Parts Description Qty Fluid TypeTechnical Data Manual and Preset Meter MetricDimensions Manual Meter Preset MeterGraco Extended Meter Warranty Graco Information