Main Icons | Select Button |
Remocon | Info Grid |
Safety Lock | Display Selection |
Port Selection | Control Tools |
|
|
1.Use the main icons to switch into each screen.
2.Allows you to enable or disable the remote control signal receiving function of the display unit.
3.Set the Safety Lock function.
When setting the Lock function, you can only operate power and lock buttons on the remote control and set.
4.The setting for the PC Serial Port can change. The original value is COM1.
5.Click Select all or Clear to select or clear all displays.
6.Use Grid to view brief information on selected display.
7.Select a display from Display Selection.
8.Use Control Tools to control displays.
<Note> The remote control Enable/Disable function operates whether or not the power is On/Off, and this applies to all displays connected to the MDC. However, regardless of the status at the time the MDC is shut down, the remote control signal receiving function of all displays is initialized to Enable when the MDC is closed.