Chapter 7. Alarm, Motion, Loss and Door Bell
1. Alarm Occurrence
The Alarm becomes available only when an Alarm Box is connected.
1)When an Alarm trigger is received, a warning buzzer sounds and the screen is divided into 9
| 02/06/01 | 12:30:01 |
|
| EVENT |
CH1 | CH2 | CH3 |
CH4 | CH5 | CH6 |
CH7 | CH8 | A 12345678 |
2)Press ENTER (in the middle of the Rotary Wheel) to replay the event in Event Replay mode. Up to 15 screens can be replayed centering on the time of the Alarm. The duration of Replay is displayed in a graph.
Turn the Rotary Wheel during the Replay to forward or reverse the stored screens one by one.
Press ENTER to terminate the Event Replay. The Event Replay will continue until ENTER has been pressed.
| 02/06/01 | 12:30:01 | |
| 1 |
| EVENT |
| CH2 | CH3 | |
|
| ||
CH4 |
| CH5 | CH6 |
|
|
| ALARM |
|
|
| 02/06/01 |
CH7 |
| CH8 | 12:29:30 |
3)Alarm occurrence information is stored in the “EVENT LIST”.
4)Alarm Out (HOT, COLD) signals are active during the “ALARM HOLD TIME. ”
•ALARM HOLD TIME : Time during which the Alarm function is carried on after the Alarm is first detected. Alarm Hold Time is reset automatically when Event Replay is turned on.