- (Minus) Key Programming

The - (Minus) key is used to enter the amount of a coupon that is subtracted from the sale.

zThe - (Minus) key can programmed to be taxable or non-taxable. In other words, when you are subtracting a coupon, you can calculate sales tax on the net or the gross cost of the item. If the - (Minus) key is taxable, you will calculate sales tax on the net cost of the item. If the - (Minus) key is -non-taxable, you will calculate sales tax on the gross cost of the item.

zYou can also program limit errors by setting the maximum amount that may be entered into the - (Minus) key. For example, setting a 3 digit limit means the maximum you can enter is $9.99. This is referred to as the High Digit Lock Out, or HDLO.

Programming the - (Minus) Key

1.Turn the control lock to the PGM position.

2.Enter the High Digit Lock Out (entry limit) digit from the table below. (Enter 0 for no limit.)

HDLO

Limits

 

 

1

.01 - .09

2

.01 - .99

3

.01 - 9.99

4

.01 - 99.99

5

.01 - 999.99

6

.01 - 9999.99

7 or 0

.01 - 99999.99

3.To decide if tax is calculated before or after the percentage is applied, complete the table below by adding the status digits for each tax. Then enter the resulting tax status code.

Calculate Rate 1 after the

Yes = 1

 

+

Minus (-) key entry?

No = 0

 

 

Calculate Rate 2 after the

Yes = 2

 

+

Minus (-) key entry?

No = 0

 

 

Calculate Rate 3 after the

Yes = 4

 

+

Minus (-) key entry?

No = 0

 

 

Calculate Rate 4 after the

Yes = 8

 

+

Minus (-) key entry?

No = 0

 

 

 

 

 

 

 

 

=

 

 

 

 

4.Enter:

0for active minus key

1for inactive minus key

5.Press the - (Minus) key.

58 • Advanced Programming Instructions

ER-290 Electronic Cash Register

Image 64
Contents Operators and Programming Manual CRS, Inc Limited Warranty and Disclaimers of Warranty Contents Advanced Programming Instructions Reports Page Using This Manual IntroductionUsing Flowcharts Keyboard Basic Features and FunctionsKey Descriptions Rtrn Mdse Minus Control Lock Display Front DisplayDisplay Messages Rear DisplayInstalling the Paper UnpackingQuick Setup ER-290 Electronic Cash Register ER-290 Electronic Cash Register Quick Setup Installing the Ribbon Clearing Memory Setting the Date Setting the TimeDate Setting Example Time Setting ExampleProgramming Tax Tax Rate Programming FlowchartProgramming a Tax Rate Percentage Tax Rate Programming Example Programming a Taxable Department Taxable Department Programming FlowchartTaxable Department Programming Example Basic Operations Registering ItemsRepeating an Item Registering Multiple ItemsTotaling a Cash Sale Tendering a Cash SaleTendering a Check Sale Total Charge SaleAdvanced Operating Instructions Department Registrations Preset Price DepartmentOpen Department Department Repeat Entry MultiplicationDepartment Multiplication With Decimal Point Split PricingSingle Item Department Preset Price PLU PLU Price Look Up RegistrationsOpen PLU PLU Repeat EntryPLU Multiplication PLU Multiplication With Decimal PointSplit Pricing PLU Shifting or Exempting Tax Shifting TaxExempting Tax Percent Key %1 and %2 Operations Preset Percent on a Department or PLU ItemEnter a Percent on a Department or PLU Return Merchandise Registrations Percent On Sale TotalVoid Last Item Voids and CorrectionsVoid Previous Item Cancel Void Position OperationsMinus Key Registrations Open Drawer No Sale OperationsNon Add Number Received On Account Operations Paid Out OperationsTotaling and Tendering Subtotaling a Sale0 1 1 9 9 9 T 1 1 9 T @ 9 2 8 T 6 T 0 T L 0 C a 0 0 3 Totaling a Charge Sale Check CashingSplit Tender Post Tender Receipt On/Off and Receipt on Request To Turn the Receipt OffTo Turn the Receipt On Printing a Receipt after the SalePage Department Programming Programming Department StatusProgramming Department Status Department Status Programming Flowchart Department Status Programming ExamplesProgramming Department Entry Limit or Price Programming a Department Entry Limit or PriceDepartment Entry Limit or Price Programming Flowchart Department Entry Limit or Price Programming ExamplesSystem Option Programming System Option FlowchartProgramming a System Option System Option Programming Examples System Option Table System Option StatusPercentage key and tax Tax Rate Programming Advanced Tax ProgrammingProgramming Tax Rates and Status Tax Rate Examples Determining Break Point Entries Tax Table ProgrammingProgramming a Tax Table Tax Table Programming Example Illinois 6% Tax Table Tax Charged Break point Sale Dollar Range Differences%2 Key Programming Programming the %1 or %2 Key1or %2Key Programming Flowchart Or %2 Key Programming ExampleMinus Key Programming Programming the Minus KeyMinus Key Programming Flowchart Minus Key Programming ExampleCancel Key Programming Programming the Cancel KeyCancel Key Programming Flowchart Cancel Key Programming ExamplePLU Price Look Up Programming Programming PLU StatusProgramming PLU Status PLU Status Programming Flowchart PLU Status Programming ExamplesProgramming PLU Entry Limit or Price Programming a PLU Entry Limit or PricePLU Entry Limit or Price Programming Flowchart PLU Entry Limit or Price Programming ExamplesSetting a Register Number Setting Receipt/Journal Status Printing a Programming ReportProgram Report Example Reports Report SummaryRunning a Report Cash-In-Drawer DeclarationDeclaring Cash Report Samples Financial ReportReports ER-290 Electronic Cash Register ER-290 Electronic Cash Register Reports Hourly Sales Report PLU Report PLU report lists the activity and sale total for each PLUCash-in-Drawer Report Check-in-Drawer ReportSystem Balancing Department Sales TotalNet Total Gross TotalJK68-6015ARev.02