Operating the
Figure 13 and Table 7 define the output Mode Setting:
Figure 13: Output Mode Setting Screen
Table 7: Output Mode Functions
Setting | Function | Range | Default |
Custom Output | Set custom values | Custom 1 to 4 |
|
HT | Horizontal total |
| 1344 |
HW | Horizontal sync pulse width |
| 136 |
HS | Horizontal active start point |
| 296 |
HA | Horizontal active region |
| 1024 |
HP | Horizontal polarity |
|
|
VT | Vertical total |
| 806 |
VW | Vertical sync pulse width |
| 6 |
VS | Vertical active start point |
| 35 |
VA | Vertical active region |
| 768 |
VP | Vertical polarity |
|
|
OCLK | Output clock |
| 65 |
Save | Click to save the settings |
|
|
Set Current | Import the values of the currently selected output |
| N/A |
| resolution into the User Mode Setting |
|
|
30 | KRAMER: SIMPLE CREATIVE TECHNOLOGY |