Precaution
This equipment is intended for indoor use only. Do not use it outdoors or at places that are exposed to rain or moisture.
Do not attach devices other than
The suffix E of model No. specifies the exclusive variant for European market.
Install this mount/bracket horizontally. Do not tilt it during use.
Do not install or use the unit in the following places.
•In a place exposed to rain or moisture.
•In a temperature outsside the operating temperature range
•In a place where corrosive gasses are generated.
•In a place subject to vibration.
When attaching
Please refer to the "INSTRUCTIONS" section of the camera in use for procedures to attach the camera.
Installing the Converter Unit
When using
Converter Unit
Clamping Bracket
Top cover
Installation Procedures
These installation should be made by a qualified service person and should conform to all local codes.
These installation should be in accordance with the National Electrical Code ANSI/NFPA 70.
Use the appropriate mounting hardware for the surface selected.
WB-S621U Pendant Mount
When a hole is not | Reinforcement Angle | |
made in the ceiling | ||
2. Safety cable | ||
Groove |
|
1. Cables
Cable
4.Fall prevention
Safety cable Mount | 3. | |
Hole ( 4.5 mm) | ||
|
Bolt (M4) | Nut (M4) |
Front Mark
FRONT Mark
1.Make a hole in the ceiling.
To route cables through the ceiling, make a hole of 30 mm ( 1 1/4) in the ceiling.
2.Route the safety cable and other cables
Route the safety cable and cables that is attached to the reinforce- ment angle through the pendant mount.
When a hole is not made in the ceiling, route the cables through the groove of the pendant Mount.
3.Mount the Pendant Mount to the Ceiling.
Attach the pendant mount to the ceiling.
CAUTION
The camera may drop or images on the screen may appear shaky if the ceiling material is not strong enough. In this case, reinforce using a reinforcement materials.
4.Connect the safety cable.
Upon removing the camera mounting plate, attach the safety cable (not supplied) to the safety cable mount hole ( 4.5 mm ( 1/8")) at the interior of the top cover using the M4 Bolt (not supplied) and M4 Nut (not supplied).
When attaching the camera mounting plate, ensure that the Front mark on the camera mounting plate is facing a direction to the Front mark on the top cover.
CAUTION
Pay particular caution to the length, strength, pull and material of the safety cable in use to prevent the plate from falling.
5.Install the ceiling panel assembly (for attach-
ing
Camera
Mounting Plate
Ceiling Panel Assy (for attaching
and
5.
Ceiling Panel A s s e m b l y Positioning Hole
Top cover
Screws
(3 locations)
To install, align the protruding part of the ceiling panel assembly with the ceiling panel assembly positioning hole near the Front mark of the camera mounting plate. Ensure to tighten the screws (3 locations) assembled to the ceiling panel assembly.
NOTE
The screws are assembled to the ceiling panel assembly in such a way that they will not come off.
6.Connect the Cables.
Connect cables to the camera.
For details, please refer to "INSTRUCTIONS" section of the camera in use.
7.Attach the camera's ceiling mount. (Not applicable
to
Attach the camera's ceiling mount to the camera mounting plate using the 4 screws (M4 x 20 mm) supplied with the pendant mount. Ensure that the FRONT mark on the camera mounting plate aligns
Protruding Partwith the Front mark on the ceiling mount.