TROUBLESHOOTING (cont.)
Problems | Points to be checked | Measures (Remedy) | Reference | |
pages | ||||
|
|
| ||
|
|
|
| |
Irregular color | Is the monitor placed or moved close to | Move the device away from the monitor. |
| |
| a speaker or any other device | Press the DEGAUSS button on the front panel to | 4 | |
| incorporating a magnet? | degauss the screen. | ||
| Has the position of the monitor been | When degaussing, wait more than 30 minutes for |
| |
| changed with the power on? | maximum effect. |
| |
|
|
|
| |
Wrong picture | Has the picture position, size or | Adjust the picture size (H SIZE, V SIZE) or |
| |
position, wrong | distortion been changed? | position (H. POSITION, V. POSITION) in the |
| |
picture size |
| [SIZE/POSI. ADJ.] item in the <SETUP MENU> |
| |
|
| screen. |
| |
|
| Adjust the picture distortion (PINCUSHION, PIN. |
| |
|
| BALANCE, TRAPEZOID and PARALLELOGRAM) | 15, 16 | |
|
| in the [DISTORTION ADJ.] item in the <SETUP |
| |
|
| MENU> screen. |
| |
|
| It may not be possible to expand the picture due |
| |
|
| to the selected input mode. In this case, |
| |
|
| adjustment is impossible. |
| |
|
|
|
| |
| Have the UNDER SCAN or ASPECT | When the UNDER SCAN or ASPECT button is | 4 | |
| button been pressed? | lit, press each button to invalidate each setting. | ||
|
| |||
|
|
|
| |
Front panel | Has the CONTROL LOCK function | Set the CONTROL LOCK function to OFF. | 16 | |
buttons and | been set to ON? |
| ||
|
| |||
knobs do not |
|
|
| |
Has the monitor’s setting been | Change the setting of the external control to |
| ||
function |
| |||
changed to enable control from an | control the monitor locally. | 17, 18 | ||
| ||||
| external unit via the REMOTE |
| ||
|
|
| ||
| terminals? |
|
| |
|
|
|
|
The following are not malfunctions:
●You may see two horizontal lines on the monitor. They are the shadows of the “damper lines” that are necessary for composing the monitor. These lines are not a malfunction.
Damper line
UNDER | PULSE | COLOR |
|
|
|
DEGAUSS SCAN | CROSS | OFF | SLOT2 | SLOT3 | POWER |
|
| SLOT1 |
|
|
|
| A | B | C | D | E | F |
VOLUME | MENU | CHECK | ASPECT | MARKER |
| INPUT SELECT |
|
| |
| BLUE | AREA |
|
|
|
|
|
●When a bright still image (such as a white cloth) is displayed for a long period, it may appear to be colored. This is due to the structure of the cathode ray tube and will disappear when another image is displayed.
●You may sometimes experience a mild electric shock when you touch the picture tube. This phenomenon is due to a normal buildup of static electricity on the CRT and is not harmful.
●The monitor emits a strange sound when the room temperature changes suddenly. This is only a problem if an abnormality appears on the screen as well.
●If two or more monitors are operated next to each other, their images may shake or be distorted. This phenomenon is due to mutual interference; it is not a malfunction. Move the monitors away from each other until the interference disappears or turn the power off on any monitor that is not being used.
20
20 | 01.3.27, 9:58 |