Operative Information
When the three LEDs light up, they indicate the power, lamp or internal temperature status or possible problems:
LED Indicator | LEDs Display | Description | |
| Orange | Standby (The AC power switch is on, | |
| and the projector is off.) | ||
|
| ||
|
| When the power button is pressed, the | |
Power | Blinking Green | indicator blinks green until the LG logo | |
| shows up. | ||
Indicator |
| ||
Green | The projector is working, | ||
| |||
| Blinking Orange | ||
|
| 90 seconds after the power is turned off. | |
| - | Off (The AC power switch is off.) | |
|
| The lamp has been in operation for over | |
|
| 1400 hours. The OSD message | |
| Orange | “CHANGE LAMP, AND RESET LAMP | |
|
| TIMER.” will be displayed on the screen | |
|
| for 30 seconds. | |
Lamp |
| The lamp has been in operation for over | |
| 1500 hours. The OSD message “OUT | ||
Indicator |
| ||
Red | OF LAMP USAGE TIME. CHANGE THE | ||
| |||
|
| LAMP!” will be displayed on the screen | |
|
| for 30 seconds. | |
|
| Something is wrong with the lamp power | |
| Blinking Red | supply. Please turn off the projector | |
|
| within 3 seconds. | |
|
| The internal temperature of the projector | |
|
| is too hot. | |
|
| When the temperature inside the | |
|
| projector is too high, the OSD message | |
| Red | “Temperature is too high. Going to shut | |
| down.” will be displayed on the screen | ||
|
| ||
Temperature |
| for 10 seconds and then the projector | |
| will automatically shutdown. The fans | ||
Indicator |
| will be continuing to run for 90 seconds, | |
|
| then you can restart the projector. | |
|
| Something is wrong with the fans. The | |
|
| OSD message “Fan or Diode error. | |
| Blinking Red | Going to shut down.” will be displayed | |
| on the screen for 10 seconds, and then | ||
|
| ||
|
| the projector will automatically | |
|
| shutdown. Please turn the projector off. |
26 |
DLP Personal Projector