Extron electronic RCP 2000 user manual Operation, cont’d, Setting Up IP Communication

Page 13

Operation, cont’d

E

Transmit and Receive LEDs — These LEDs flicker whenever

 

Ethernet or RS-232 data to or from the ISS 506 is being

 

transmitted or received by the RCP 2000.

F

Adjust knob — Allows adjustment of menu selections. See

 

“Setting the Display Mode” or “Transition Sub-effects,” later in

 

this chapter.

G

Transition effect buttons — Control the type of switch that

 

occurs between program and preview inputs.

 

Cut button — Initiates an immediate seamless transition

 

 

between the program and preview images. In PIP and

 

 

Title modes, it seamlessly opens or closes the picture-in-

 

 

picture or title window.

 

Dissolve button — Puts the RCP in Dissolve mode, in

 

 

which the program input fades out while the preview

 

 

input fades in. The dissolve duration is adjustable.

 

N To achieve a dissolve effect when opening or closing the

 

 

preview window in PIP mode, select sub-effect #01.

 

 

In addition, you can press this button while holding down

 

 

the Wipe button to cycle through the mode menu options

 

 

(Wipe, PIP, and Title).

 

Wipe button — In conjunction with the Dissolve button,

 

 

selects the display mode (Wipe, PIP, or Title). The Wipe

 

 

button can also be used as follows:

 

 

In Wipe or PIP mode:

 

 

¡ Select a sub-effect by holding down the Wipe button

 

 

and rotating the Adjust knob until the desired sub-

 

 

effect number is displayed in the LCD window.

 

 

¡ Select the duration of the selected sub-effect by

 

 

pressing and releasing the Wipe button and rotating

 

 

the Adjust knob while Wipe remains lit.

 

 

In Title mode:

 

 

¡ Adjust the intensity level at or above which the

 

 

preview image becomes visible over the program

 

 

image, by holding down Wipe button and rotating the

 

 

Adjust knob.

 

Take button — Initiates the switch selected through the

 

 

transition effect buttons.

H

T-bar controller — Allows you to manually override the

 

duration of an effect by moving the T-bar handle up or down.

(The T-bar cannot be used with a cut or title.)

I LCD display — Displays status information and menu screens.

J

Wipe and PIP Sub-effects label — Lists the names and brief

 

descriptions of the transition sub-effects that are available when

 

the RCP is in Wipe or PIP mode.

K

Horizontal Adjust knob — Allows horizontal adjustments to

 

the centering, sizing, and detail picture controls. Contrast and

 

color are also adjusted using this knob. After selecting an input,

 

press the desired picture control button and rotate this knob to

 

make the adjustment to the preview input.

L

Vertical Adjust knob — Allows vertical adjustments to the

 

centering, sizing, and detail picture controls. Brightness and tint

 

are also adjusted using this knob. After selecting an input, press

 

the desired picture control button and rotate this knob to make

 

the adjustment to the preview input.

M

Picture control buttons — Allow you to make adjustments to

 

the picture for the preview output. The five control buttons

 

control color and tint, contrast and brightness (Cont/Bright),

 

sizing (Size), centering (Center), and detail. These buttons light

 

when pressed. See “Using the Picture Controls,” later in this

 

chapter.

 

After a preview input is selected, press the desired picture

 

control button, then rotate the appropriate encoder knob

 

(H or V) while viewing the output display. You can adjust the

 

centering, sizing, and detail horizontally or vertically using the

 

horizontal (H) and vertical (V) adjustment knobs. Contrast and

 

color are adjusted. using the H knob; brightness and tint are

 

adjusted using the V knob.

Setting Up IP Communication

The RCP 2000 is delivered with a factory default IP address of 192.168.254.253. If you want to change this address, or you need to enter other information required for Ethernet or serial communication, follow these steps to set up IP communication via the top panel:

1. Press the Color/Tint, Cont/Bright, Size, and Center Picture Control buttons simultaneously, and hold them until the Cut button lights (about 2 seconds). The RCP’s MAC address (XX-XX-XX-XX-XX-XX) is displayed on the LCD screen.

3-4

RCP 2000 with ISS 506 Support • Operation

RCP 2000 with ISS 506 Support • Operation

3-5

Image 13
Contents Extron USA East Remote Control PanelExtron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文Set the RCP 2000 on a table, podium, or other flat surface Quick Start Guide ­- RCP 2000 with ISS SupportQS-1 Table of Contents Introduction Table of Contents, cont’dRCP 2000 with ISS 506 Support Features Application DiagramIntroduction About this ManualIntroduction, cont’d InstallationInstallation Overview InstallationBack Panel Features and Connections Making an RCP Communication CableWhen connecting the RCP Installation, cont’dEthernet link Operation Top Panel Controls OperationRCP 2000 with ISS 506 support top panel RCP 2000 with ISS 506 Support OperationOperation, cont’d Setting Up IP CommunicationEntering IP setup mode Setting Up RS-232 CommunicationRotate the H Adjust knob to change the selected value Adjusting the IP settingsMode menu options Setting the Display ModeDefault cycle Default cyclePIP picture-in-picture mode Dissolve modeTitle mode Transition Sub-effects Using a CutSub-effects available in wipe and PIP modes Standard wipesSetting a transition sub-effect Using the Picture Controls Ethernet Control ResettingSystem Settings screen Using the Configuration ScreensEthernet Control Establishing a ConnectionEntering IP and date/time settings RCP 2000 System Settings screenConfiguring the ISS 506 switcher Ethernet Control, cont’dManaging Files Firmware Upgrade screenUpdating the firmware Uploading filesOther file management activities Adding a directoryFile Management screen AAppendix a Specifications and Part NumbersSpecifications RCP 2000 with ISS 506 Support Specifications and Part NumbersControl/Remote Control Panel Part NumbersSpecifications and Part Numbers, cont’d
Related manuals
Manual 23 pages 17.17 Kb

RCP 2000 specifications

The Extron RCP 2000 is a prominent tool in the realm of control systems, designed to enhance user experience in various environments, including educational institutions, corporate settings, and large venues. This remote control panel is engineered for streamlined operation of audio-visual equipment, serving as an indispensable component in managing multimedia presentations.

One of the main features of the RCP 2000 is its intuitive interface. Equipped with a backlit, tactile keypad, users can easily find and operate functions even in low-light settings. The ergonomic layout provides quick access to essential controls, such as volume adjustments, source selection, and macro commands, ensuring a user-friendly experience. The inclusion of customizable buttons allows for flexibility, enabling users to tailor the panel to their specific needs.

Another notable characteristic is its support for a wide range of audiovisual technologies. The RCP 2000 is compatible with Extron's extensive line of products and integrates seamlessly with other equipment, facilitating a cohesive system. This compatibility is further enriched by the device’s ability to support IP-based control, allowing for remote monitoring and programming, which is crucial for managing complex AV systems across multiple locations.

The RCP 2000 also features robust connectivity options, including Ethernet for network integration and RS-232 ports for direct control of hardware devices. This versatility enhances its functionality and ensures compatibility with many modern AV systems. Additionally, the panel supports multiple control protocols, making it adaptable to varied environments and distinct user preferences.

In terms of build quality, the Extron RCP 2000 maintains a high standard. It is constructed from durable materials, designed to withstand daily usage while maintaining its aesthetic appeal. Its compact design allows for easy installation, whether mounted on walls or placed on tables, making it a practical option for space-constrained areas.

In summary, the Extron RCP 2000 stands out with its user-friendly interface, extensive compatibility with audiovisual technologies, and robust construction. These features make it an ideal choice for efficient AV management, ensuring that users can focus on delivering impactful presentations without the hassle of complex control systems.