Extron electronic RCP 2000 Using a Cut, Transition Sub-effects, Standard wipes, Curtain wipes

Page 17

Operation, cont’d

3. If necessary, select a preview input.

4. To execute a switch with the dissolve effect, press the Take button, which blinks while the transition is in progress.

-or-

Slide the T-bar up or down to control the dissolve duration manually.

Using a Cut

A cut transition immediately and seamlessly replaces the program image with the preview image, in wipe or dissolve mode. In PIP mode, it closes or opens the PIP window. No transition effect is applied to the switch.

NIf you want to switch using your current transition effect, press the Take button instead of the Cut button.

To execute a cut when the RCP is in wipe, dissolve, or PIP mode, 1. If necessary, select the preview input.

2. Press the Cut button. The seamless switch takes effect immediately. The preview image becomes the new program image (wipe or dissolve mode) or the PIP window closes or opens (PIP mode).

NIn PIP mode, you cannot select a cut from the PIP sub- effects menu; you must press the Cut button to instantly open or close the PIP window.

Transition Sub-effects

A variety of visual effects are available for transitioning between the preview and the program displays in wipe and PIP modes. The sub-effects that are available depend on the display mode in which the RCP is operating. (See “Setting the Display Mode,” earlier in this chapter.) You can also set the duration of the sub-effect.

Sub-effects available in wipe and PIP modes

The sub-effects described in the following sections can be selected for the transition between the displayed preview and program inputs in wipe and PIP modes. These sub-effects are listed on the label shown on the next page, which is located to the right of the H and V Adjust knobs on the RCP top panel.

Wipe and PIP Sub-effects

01 = Dissolve (PIP only)

10

= Soft Square In

18 = Hard Center In

02

= Soft Right

11 = Soft Square Out

19 = Hard Center Out

03

= Soft Left

12

= Soft Plus In

20

= Hard Curtain In

04

= Soft Up

13

= Soft Plus Out

21 = Hard Curtain Out

05

= Soft Down

14

= Hard Right

22

= Hard Square In

06

= Soft Center In

15

= Hard Left

23

= Hard Square Out

07 = Soft Center Out

16

= Hard Up

24

= Hard Plus In

08

= Soft Curtain In

17

= Hard Down

25

= Hard Plus Out

09

= Soft Curtain Out

 

 

 

33-1635-01 Rev A

 

 

 

 

 

 

 

 

 

 

03 08

Standard wipes

A standard wipe sub-effect causes the preview image to appear to unroll over the program image horizontally or vertically. A standard wipe can have either hard (sharp) or soft (blurred) edges.

The following standard wipes are available:

From left to right — Soft Right (#02) or Hard Right (#14)

From right to left — Soft Left (#03) or Hard Left (#15)

From top to bottom — Soft Up (#04) or Hard Up (#16)

From bottom to top — Soft Down (#05) or Hard Down (#17)

Left to right

Right to left

Bottom to top

Top to bottom

(#02 or #14)

(#03 or #15)

(#04 or #16)

(#05 or #17)

Curtain wipes

A curtain wipe causes the preview image to appear to unroll over the program image in two directions simultaneously. A curtain wipe can have either hard (sharp) or soft (blurred) edges.

The following curtain wipes are available:

In from the left and right edges to the center of the screen — Soft Curtain In (#08) or Hard Curtain In (#20)

Out from the center to the left and right edges of the screen — Soft Curtain Out (#09) or Hard Curtain Out (#21)

3-12 RCP 2000 with ISS 506 Support • Operation

RCP 2000 with ISS 506 Support • Operation 3-13

Image 17
Contents Extron USA East Remote Control PanelExtron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文QS-1 Quick Start Guide ­- RCP 2000 with ISS SupportSet the RCP 2000 on a table, podium, or other flat surface Table of Contents RCP 2000 with ISS 506 Support Table of Contents, cont’dIntroduction Features Application DiagramIntroduction About this ManualIntroduction, cont’d InstallationInstallation Overview InstallationBack Panel Features and Connections Making an RCP Communication CableEthernet link Installation, cont’dWhen connecting the RCP Operation Top Panel Controls OperationRCP 2000 with ISS 506 support top panel RCP 2000 with ISS 506 Support OperationOperation, cont’d Setting Up IP CommunicationEntering IP setup mode Setting Up RS-232 CommunicationRotate the H Adjust knob to change the selected value Adjusting the IP settingsMode menu options Setting the Display ModeDefault cycle Default cycleTitle mode Dissolve modePIP picture-in-picture mode Transition Sub-effects Using a CutSub-effects available in wipe and PIP modes Standard wipesSetting a transition sub-effect Using the Picture Controls Ethernet Control ResettingSystem Settings screen Using the Configuration ScreensEthernet Control Establishing a ConnectionEntering IP and date/time settings RCP 2000 System Settings screenConfiguring the ISS 506 switcher Ethernet Control, cont’dManaging Files Firmware Upgrade screenUpdating the firmware Uploading filesFile Management screen Adding a directoryOther file management activities AAppendix a Specifications and Part NumbersSpecifications RCP 2000 with ISS 506 Support Specifications and Part NumbersControl/Remote Control Panel Part NumbersSpecifications and Part Numbers, cont’d
Related manuals
Manual 23 pages 17.17 Kb

RCP 2000 specifications

The Extron RCP 2000 is a prominent tool in the realm of control systems, designed to enhance user experience in various environments, including educational institutions, corporate settings, and large venues. This remote control panel is engineered for streamlined operation of audio-visual equipment, serving as an indispensable component in managing multimedia presentations.

One of the main features of the RCP 2000 is its intuitive interface. Equipped with a backlit, tactile keypad, users can easily find and operate functions even in low-light settings. The ergonomic layout provides quick access to essential controls, such as volume adjustments, source selection, and macro commands, ensuring a user-friendly experience. The inclusion of customizable buttons allows for flexibility, enabling users to tailor the panel to their specific needs.

Another notable characteristic is its support for a wide range of audiovisual technologies. The RCP 2000 is compatible with Extron's extensive line of products and integrates seamlessly with other equipment, facilitating a cohesive system. This compatibility is further enriched by the device’s ability to support IP-based control, allowing for remote monitoring and programming, which is crucial for managing complex AV systems across multiple locations.

The RCP 2000 also features robust connectivity options, including Ethernet for network integration and RS-232 ports for direct control of hardware devices. This versatility enhances its functionality and ensures compatibility with many modern AV systems. Additionally, the panel supports multiple control protocols, making it adaptable to varied environments and distinct user preferences.

In terms of build quality, the Extron RCP 2000 maintains a high standard. It is constructed from durable materials, designed to withstand daily usage while maintaining its aesthetic appeal. Its compact design allows for easy installation, whether mounted on walls or placed on tables, making it a practical option for space-constrained areas.

In summary, the Extron RCP 2000 stands out with its user-friendly interface, extensive compatibility with audiovisual technologies, and robust construction. These features make it an ideal choice for efficient AV management, ensuring that users can focus on delivering impactful presentations without the hassle of complex control systems.