Extron electronic RCP 2000 user manual Using the Picture Controls

Page 19

Operation, cont’d

4. Release the Wipe button and, while the button remains lit, rotate the Adjust knob to set the amount of seconds that the sub-effect will appear on the screen. You can set the duration of the PIP sub-effect in increments of tenths of a second, 0.0 to 0.5 seconds.

Switching with a transition sub-effect

After you have set up a transition sub-effect and its duration, do the following to execute a transition from the preview input to the program input and vice versa:

Press the Take button. -or-

Move the T-bar up or down to manually control the effect.

In Wipe mode, the button blinks while the transition is taking place.

In PIP mode, the button continues to blink while the PIP window is open. To close the window, press Cut or Take, or slide the T-bar all the way up or down.

Using the Picture Controls

The picture controls allow you to adjust the centering, size, detail, contrast/brightness, and color/tint of the preview image.

1. Select a preview input by pressing one of the Preview Input buttons (buttons 1 through 6).

2. Press the desired Picture Controls button. The button lights.

3. While the button is lit, rotate the H and/or V knob to make your adjustment(s).

4. To exit the picture control, wait for the button’s light to go out, or press another Preview Input, Picture Controls, or Transition Effects button.

Adjusting color and tint

1. Press and release the Color/Tint button. The button lights.

2. While the Color/Tint button is lit,

Rotate the H Adjust knob to change the color.

Rotate the V Adjust knob to change the tint.

Adjusting contrast and brightness

1. Press and release the Cont/Bright button. The button lights.

2. While the Cont/Bright button is lit,

Rotate the H Adjust knob to change the contrast.

Rotate the V Adjust knob to change the brightness.

Sizing an image

1. Press and release the Size button. The button lights.

2. While the Size button is lit,

Rotate the V Adjust knob to adjust the vertical size (height).

Rotate the H Adjust knob to adjust the horizontal size (width).

Resizing in PIP mode

To resize the image and/or the PIP window while the RCP is in PIP mode,

1. Press the Size button once to enable window resizing.

2. Press the Size button again as needed to toggle between PIP window size adjustment and image size adjustment.

3. Rotate the H and V Adjust knobs to adjust the width and height of the PIP window or the image.

The Size button stays lit steadily while you are adjusting the PIP window size and blinks while you are adjusting the image size.

Centering an image

To position the image on the screen,

1. Press and release the Center button. The button lights.

2. Rotate the V Adjust knob to adjust the image position vertically.

3. Rotate the H Adjust knob to adjust the image position horizontally.

Centering in PIP mode

To adjust the position of the image and/or the PIP window while the RCP is in PIP mode,

1. Press the Center button once to enable window centering.

2. Press the Center button again as needed to toggle between PIP window positioning and image positioning.

3-16 RCP 2000 with ISS 506 Support • Operation

RCP 2000 with ISS 506 Support • Operation 3-17

Image 19
Contents Extron USA East Remote Control PanelExtron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文Set the RCP 2000 on a table, podium, or other flat surface Quick Start Guide ­- RCP 2000 with ISS SupportQS-1 Table of Contents Introduction Table of Contents, cont’dRCP 2000 with ISS 506 Support About this Manual Application DiagramFeatures IntroductionIntroduction, cont’d InstallationMaking an RCP Communication Cable InstallationInstallation Overview Back Panel Features and ConnectionsWhen connecting the RCP Installation, cont’dEthernet link Operation RCP 2000 with ISS 506 Support Operation OperationTop Panel Controls RCP 2000 with ISS 506 support top panelOperation, cont’d Setting Up IP CommunicationAdjusting the IP settings Setting Up RS-232 CommunicationEntering IP setup mode Rotate the H Adjust knob to change the selected valueDefault cycle Setting the Display ModeMode menu options Default cyclePIP picture-in-picture mode Dissolve modeTitle mode Standard wipes Using a CutTransition Sub-effects Sub-effects available in wipe and PIP modesSetting a transition sub-effect Using the Picture Controls Ethernet Control ResettingEstablishing a Connection Using the Configuration ScreensSystem Settings screen Ethernet ControlEthernet Control, cont’d RCP 2000 System Settings screenEntering IP and date/time settings Configuring the ISS 506 switcherUploading files Firmware Upgrade screenManaging Files Updating the firmwareOther file management activities Adding a directoryFile Management screen AAppendix a Specifications and Part NumbersPart Numbers Specifications and Part NumbersSpecifications RCP 2000 with ISS 506 Support Control/Remote Control PanelSpecifications and Part Numbers, cont’d
Related manuals
Manual 23 pages 17.17 Kb

RCP 2000 specifications

The Extron RCP 2000 is a prominent tool in the realm of control systems, designed to enhance user experience in various environments, including educational institutions, corporate settings, and large venues. This remote control panel is engineered for streamlined operation of audio-visual equipment, serving as an indispensable component in managing multimedia presentations.

One of the main features of the RCP 2000 is its intuitive interface. Equipped with a backlit, tactile keypad, users can easily find and operate functions even in low-light settings. The ergonomic layout provides quick access to essential controls, such as volume adjustments, source selection, and macro commands, ensuring a user-friendly experience. The inclusion of customizable buttons allows for flexibility, enabling users to tailor the panel to their specific needs.

Another notable characteristic is its support for a wide range of audiovisual technologies. The RCP 2000 is compatible with Extron's extensive line of products and integrates seamlessly with other equipment, facilitating a cohesive system. This compatibility is further enriched by the device’s ability to support IP-based control, allowing for remote monitoring and programming, which is crucial for managing complex AV systems across multiple locations.

The RCP 2000 also features robust connectivity options, including Ethernet for network integration and RS-232 ports for direct control of hardware devices. This versatility enhances its functionality and ensures compatibility with many modern AV systems. Additionally, the panel supports multiple control protocols, making it adaptable to varied environments and distinct user preferences.

In terms of build quality, the Extron RCP 2000 maintains a high standard. It is constructed from durable materials, designed to withstand daily usage while maintaining its aesthetic appeal. Its compact design allows for easy installation, whether mounted on walls or placed on tables, making it a practical option for space-constrained areas.

In summary, the Extron RCP 2000 stands out with its user-friendly interface, extensive compatibility with audiovisual technologies, and robust construction. These features make it an ideal choice for efficient AV management, ensuring that users can focus on delivering impactful presentations without the hassle of complex control systems.