Teledyne T200U-NOy manual T200U-NOY Spare Parts List, Partnumber Description

Page 39

8.0 T200U-NOY SPARE PARTS LIST

The following spare parts list supplements the spare parts list for the T200U analyzer.

Note

Use of replacement parts other than those supplied by API may result in non-compliance with European Standard EN 61010-1.

Note

Due to the dynamic nature of part numbers, please refer to the TAPI Website at http://www.teledyne-api.com or call Customer Service at 800-324-5190 for more recent updates to part numbers.

Reference: 06848 11/8/2010 1:13:10 PM

 

 

 

 

PARTNUMBER

DESCRIPTION

 

000940100

CD, ORIFICE, .003 GREEN

 

000940400

CD, ORIFICE, .004 BLUE

 

000941100

CD, ORIFICE, .014 ORG/VIOLET

 

001330001

SLEEVE, GOLD PLATED, NOX

 

001761800

ASSY, FLOW CTL, 90CC, 1/4" TEE-TMT, B

 

002270100

AKIT, GASKETS, WINDOW, (12 GASKETS = 1)

 

002730000

CD, FILTER, 665NM (KB)

 

004330000

ZERO AIR SCRUBBER (NO/NO2)

 

005960000

AKIT, EXP, 6LBS ACT CHARCOAL (2 BT=1)

 

005970000

AKIT, EXP, 6LB PURAFIL (2BT=1)

 

009690200

AKIT, TFE FLTR ELEM (FL19,100=1) 47mm

 

009690300

AKIT, TFE FLTR ELEM (FL19, 30=1) 47mm

 

011310000

ASSY, DRYER, NOX

 

011630000

HVPS INSULATOR GASKET (KB)

 

013140000

ASSY, COOLER FAN (NOX/SOX)

 

014030000

AKIT, NOX EXPENDABLES, IZS

 

014080200

ASSY, HVPS, NOX

 

016290000

WINDOW, SAMPLE FILTER, 47MM (KB)

 

016300900

ASSY, SAMPLE FILTER, 47MM, ANG BKT, 5UM

 

024600100

ASSY, PREREACTOR NO/NOX VALVE

 

024930000

CD, PMT, NOX

 

037860000

ORING, TEFLON, RETAINING RING, 47MM (KB)

 

039700100

HEATER, BAND, TYPE K, DUAL VOLTAGE(KB)

 

040010000

ASSY, FAN REAR PANEL

 

040030800

PCA, PRESS SENSORS (2X), FLOW, (NOX)

 

040400000

ASSY, HEATERS/THERMAL SWITCH, RX CELL

 

040410500

ASSY, VACUUM MANIFOLD

 

040420200

ASSY, O3 GEN BRK, HIGH-O/P

 

041510200

ASSY, PRESS/FLOW SENSOR, NOX

 

041800300

PCA, PMT PREAMP, (OBS)

 

 

 

 

07303C DCN6646

37

Image 39
Contents T200U-NOy Analyzer Page Safety Messages Consignes DE Sécurité Warranty This page intentionally left blank Table of Contents List of Figures Introduction 07303C DCN6646 Specifications SpecificationsModel T200EU-NOy Option Manual Addendum 2.0 Specifications Unpacking and Inspection Getting StartedElectrical and Pneumatic Connections Model T200U-NOy Option Manual Addendum Rear Panel Pneumatic Connections Final Test and Calibration Values Initial OperationThis page intentionally left blank Principle of Operation T200U-NOY External ConverterThis page intentionally left blank Calibration and CAL Checks Manual Zero Calibration Procedure Calibration or Cal Check ProcedureSpan Calibration Procedure This page intentionally left blank Maintenance Schedule MaintenanceReplacing the Sample Particulate Filters Replacing the Particulate Filter Replacing the Converter Checking Analyzer Flow RateInspecting Pneumatic Lines NOy Converter Guts Assembly LocationPneumatics Location of O3 Generator Air Inlet Checking for LeaksPressure must be less than 15 PSI Operation Verification Diagnostic Techniques TROUBLESHOOTING, Adjustments3 501Y Bypass Pump Diagnostic Procedures Setting the Converter TemperatureLOC Lock AH Alarm Electrical Diagram This page intentionally left blank Partnumber Description T200U-NOY Spare Parts ListPCA, PMT PREAMP, VR FILTER, SS KB This page intentionally left blank

T200U-NOy specifications

The Teledyne T200U-NOy is an advanced gas analyzer specifically designed to measure nitrogen oxides (NOx) concentrations in a variety of applications, including industrial emissions monitoring, environmental assessments, and combustion control. It builds upon Teledyne's legacy of producing high-quality analytical instruments, making it a reliable choice for professionals in the field.

One of the main features of the T200U-NOy is its ability to measure multiple nitrogen oxides, including nitrogen dioxide (NO2), nitric oxide (NO), and nitrous oxide (N2O), which are critical for understanding and managing air quality and combustion efficiency. The instrument offers high sensitivity and accuracy, allowing for real-time monitoring of NOx levels with a detection limit that suits stringent regulatory requirements.

The T200U-NOy utilizes advanced chemiluminescence technology for NO measurement, which is widely recognized for its reliability and precision. This method involves the reaction of NO with ozone (O3) to produce excited NO2, which subsequently releases light as it returns to a lower energy state. The intensity of this light is measured and directly correlates to the concentration of NO in the sample, providing highly accurate readings.

In addition to its core measurement capabilities, the T200U-NOy is equipped with a variety of features that enhance its functionality. Its user-friendly interface allows for easy configuration and data retrieval, making it accessible to a wide range of users, from seasoned professionals to those new to gas analysis. The device supports multiple communication protocols, including analog and digital outputs, facilitating integration into existing monitoring systems.

The T200U-NOy is constructed with robust materials designed to withstand harsh industrial environments, ensuring longevity and reliability. It also includes features for easy maintenance, such as user-replaceable parts, which can significantly reduce downtime.

Overall, the Teledyne T200U-NOy stands out in the field of gas analyzers, combining cutting-edge measurement technologies with user-centric features and robust construction. Its comprehensive capabilities make it an essential tool for accurately monitoring nitrogen oxides, ultimately contributing to better environmental protection and compliance with air quality regulations.