Teledyne T200U-NOy manual Pca, Pmt Preamp, Vr

Page 40

Model T200U-NOy Option Manual Addendum

Reference: 06848 11/8/2010 1:13:10 PM

PARTNUMBER

DESCRIPTION

041800600

PCA, PMT PREAMP, VR,

041920000

ASSY, THERMISTOR

042680100

ASSY, VALVE (SS)

043420000

ASSY, HEATER/THERM, O2 SEN

044340000

ASSY, HTR, BYPASS MANIFOLD

044540000

ASSY, THERMISTOR, NOX

044600000

AKIT, SPARES, NOX

045230100

PCA, RELAY CARD

045230200

PCA, RELAY CARD

045430000

ASSY, DRYER, O3, W/RELAYS & BRKT *

04550010A

ASSY, ORIFICE HOLDER, 4 MIL

04550030A

ASSY, ORIFICE HOLDER, 10 MIL, (NOX) (KB)

045500400

ASSY, ORIFICE HOLDER, 3 MIL

046030000

AKIT, CH-43, 3 REFILLS

046480000

ASSY, DILUTION MANIFOLD, (KB)

046490000

OPTION, DILUTION MANIFOLD (KB)

047150000

AKIT, EXPENDABLES, NOX

049310100

PCA,TEC DRIVER,PMT,(KB)

049760300

ASSY, TC PROG PLUG, MOLY,TYP K, TC1

050700200

KIT, RELAY BD NOX CONFIGURATION

051210000

DESTRUCT w/FTGS, O3 *

051990000

ASSY, SCRUBBER, INLINE EXHAUST, DISPOS

052820000

ASSY, IZS, HEATER/THERM, NOX

052930200

ASSY, BAND HEATER TYPE K, NOX

055300000

AKIT, PUMP REBUILD, THOMAS 2688, DUAL HD

055740000

ASSY, PUMP, NOx PUMP PACK, 115V/60HZ

055740100

ASSY, PUMP, NOx PUMP PACK, 220V/60HZ

055740200

ASSY, PUMP, NOx PUMP PACK, 220V/50HZ

056490000

FILTER, DFU, DESORBER (SOAKED)

058021100

PCA, MOTHERBD, GEN 5-ICOP

058230000

ASSY, O3 CLEANSER, ALUMINUM

059940000

OPTION, SAMPLE GAS CONDITIONER, NOX*

062390000

ASSY, MOLY GUTS w/WOOL

064540000

ASSY, PUMP NOX INTERNAL, 115V/60HZ

064540100

ASSY, PUMP NOX INTERNAL, 230V/60HZ

064540200

ASSY, PUMP NOX INTERNAL, 230V/50HZ

066970000

PCA, INTRF. LCD TOUCH SCRN, F/P

067240000

CPU, PC-104, VSX-6154E, ICOP *

067300000

PCA, AUX-I/O BD, ETHERNET, ANALOG & USB

067300100

PCA, AUX-I/O BOARD, ETHERNET

067300200

PCA, AUX-I/O BOARD, ETHERNET & USB

067900000

LCD MODULE, W/TOUCHSCREEN

068250100

DOM, w/SOFTWARE, STD, T200U *

068810000

PCA, LVDS TRANSMITTER BOARD

069500000

PCA, SERIAL & VIDEO INTERFACE BOARD

072150000

ASSY. TOUCHSCREEN CONTROL MODULE

072820000

KIT, T200U MANUAL

38

07303C DCN6646

Image 40
Contents T200U-NOy Analyzer Page Safety Messages Consignes DE Sécurité Warranty This page intentionally left blank Table of Contents List of Figures Introduction 07303C DCN6646 Specifications SpecificationsModel T200EU-NOy Option Manual Addendum 2.0 Specifications Getting Started Unpacking and InspectionElectrical and Pneumatic Connections Model T200U-NOy Option Manual Addendum Rear Panel Pneumatic Connections Initial Operation Final Test and Calibration ValuesThis page intentionally left blank T200U-NOY External Converter Principle of OperationThis page intentionally left blank Calibration and CAL Checks Calibration or Cal Check Procedure Manual Zero Calibration ProcedureSpan Calibration Procedure This page intentionally left blank Maintenance Maintenance ScheduleReplacing the Sample Particulate Filters Replacing the Particulate Filter Checking Analyzer Flow Rate Replacing the ConverterNOy Converter Guts Assembly Location Inspecting Pneumatic LinesPneumatics Checking for Leaks Location of O3 Generator Air InletPressure must be less than 15 PSI TROUBLESHOOTING, Adjustments Operation Verification Diagnostic TechniquesSetting the Converter Temperature 3 501Y Bypass Pump Diagnostic ProceduresLOC Lock AH Alarm Electrical Diagram This page intentionally left blank T200U-NOY Spare Parts List Partnumber DescriptionPCA, PMT PREAMP, VR FILTER, SS KB This page intentionally left blank

T200U-NOy specifications

The Teledyne T200U-NOy is an advanced gas analyzer specifically designed to measure nitrogen oxides (NOx) concentrations in a variety of applications, including industrial emissions monitoring, environmental assessments, and combustion control. It builds upon Teledyne's legacy of producing high-quality analytical instruments, making it a reliable choice for professionals in the field.

One of the main features of the T200U-NOy is its ability to measure multiple nitrogen oxides, including nitrogen dioxide (NO2), nitric oxide (NO), and nitrous oxide (N2O), which are critical for understanding and managing air quality and combustion efficiency. The instrument offers high sensitivity and accuracy, allowing for real-time monitoring of NOx levels with a detection limit that suits stringent regulatory requirements.

The T200U-NOy utilizes advanced chemiluminescence technology for NO measurement, which is widely recognized for its reliability and precision. This method involves the reaction of NO with ozone (O3) to produce excited NO2, which subsequently releases light as it returns to a lower energy state. The intensity of this light is measured and directly correlates to the concentration of NO in the sample, providing highly accurate readings.

In addition to its core measurement capabilities, the T200U-NOy is equipped with a variety of features that enhance its functionality. Its user-friendly interface allows for easy configuration and data retrieval, making it accessible to a wide range of users, from seasoned professionals to those new to gas analysis. The device supports multiple communication protocols, including analog and digital outputs, facilitating integration into existing monitoring systems.

The T200U-NOy is constructed with robust materials designed to withstand harsh industrial environments, ensuring longevity and reliability. It also includes features for easy maintenance, such as user-replaceable parts, which can significantly reduce downtime.

Overall, the Teledyne T200U-NOy stands out in the field of gas analyzers, combining cutting-edge measurement technologies with user-centric features and robust construction. Its comprehensive capabilities make it an essential tool for accurately monitoring nitrogen oxides, ultimately contributing to better environmental protection and compliance with air quality regulations.