Vidikron Vision 150, Vision 140 operation manual Easily maintained as the lamp ages

Page 75

For example, a 1000-Watt lamp can be driven at no more than 1000 Watts. To produce desired brightness at the screen, a new lamp would likely need less than this maximum rating — perhaps 812 Watts (example only). Over time, however, the lamp requires more and more current in order to generate the desired light, until eventually the lamp wattage reaches its 1000-Watt maximum and the lamp power automatically levels off. At this point, the tracking function terminates (that is, the power level stabilizes) and the lamp begins to dim normally. Either reduce your “Intensity” setting or replace the lamp.

Do not lower the “Intensity” so much that the corresponding “Power” value reaches its minimum — the intensity setting will be inaccurate and cannot be maintained.

1. Lamps become more stable over time, thus a specific intensity is more

Note

easily maintained as the lamp ages.

 

 

2. Intensity can be set only if the lamp is in “Intensity” mode

 

3. Intensity cannot exceed the output of Max Brightness mode.

Aperture Control: The optical aperture inside the projector controls the diameter of the light beam passing through the system. With a fully open aperture (slidebar default of “0”), the maximum amount of light passes through for maximum brightness in your images. Increase the slidebar setting to reduce the aperture diameter and maximize contrast ratio instead.

Lamp History (read-only):Lamp History shows the lamps most recently installed and recorded in the projector. The Lamp History automatically updates whenever you record a new lamp serial number; the new lamp is added to the end of the list.

Change Lamp: Select Change Lamp from the Lamp menu to record the serial number for a newly-installed lamp. For detailed lamp replacement instructions, refer to Lamp and Filter Replacement on page 81.

RVR

7

Vision Model 140/150 Installation/Operation Manual

61

Image 75
Contents 140/150 Page TWO Year Limited Warranty RIGHTS, Limits and Exclusions Product Information Retain for Your Records Important Safety Instructions Declaration of Conformity Compliance InformationFCC Part 1Table of Contents Attach Lens Mounting Assembly to Lens Motor Carriage Plate Serial Communications Maintenance and TroubleshootingSpecifications OperationTable of Contents Xii 1List of Figures List of Figures This Manual Carriage return must be used after each command or string1Introduction About This ManualIf you need Turn to Using This ManualThey also provide supplemental information Performance or cause a malfunctionDescription, Features and Benefits Optional Accessories Vision 140/150 at a Glance 2Controls and FunctionsLED Status Display Adjustable FeetTOP IR Sensor BUILT-IN Keypad Input PanelInput 1 Rgbhv Vision 140/150 Input PanelRemote EthernetVision 140/150 Rear-Panel Keypad Right Button UP ButtonLeft Button Down ButtonVHD Controller Front Panel IR SensorVacuum Fluorescent Display Composite Video Input VHD Controller Rear PanelHdmi OUT InputsMain AC Fuse Power Input 100 to 240 VACMain Power Switch RS-232 Control PortVHD Controller/Vision 140/150 Remote Control Vision 140/150 Remote Control UnitIR Output Indicator LightRETURN/EXIT Cinema ISF DAYControls and Functions Operation 3InstallationRemote Control To install batteries in the remote controlInstallation Quick Setup Installation OverviewStep Procedure For Details, Refer to Advantages Considerations Installation ConsiderationsProjector Installation Options Installation TypeScreen Vision 140/150 Lens Options and Throw RatiosThrow Ratio With 126.9x54-inchVertical and Horizontal Lens Ceiling InstallationFloor Installation PositionHorizontal Lens Shift Example only Vertical and Horizontal Lens Shift Limits Folded Optics Lens Assembly Front View Installing the Projection LensAnamorphic lens mounting kit is partially pre-assembled at Installing the Optional CineWide Lens MountLens motor installed Ceiling-mounting an AutoScope-equipped projectorFloor-Mount Angle Adjusting the ProjectionMounting the Vision 140/150 Floor Mounting UprightConnecting the VHD Connections to the Vision 140/150 and VHD Controller140/150 Connecting Source Hdmi Connections See FigureController 11. Digital DTV RGB or Component Video Connections Digital DTV RGB or Component Video Connections See FigurePersonal Computer Analog Computer RGB Connections See FigureDVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See Figure14. RS-232 Control System Connection ConnectionEquipment Connecting 12-Volt TriggerConnecting an External IR Receiver to the VHD Controller Power sourceProjector Component SD Ntsc 480i 169 V150 Turning on the PowerFocus Zoom Vertical and Horizontal Lens Shift Adjusting the Picture Orientation Primary Lens AdjustmentsPlate fixed CineWide Installing and Adjusting the CineWide Anamorphic LensHorizontal Position X Adjustment Installation Geometry Anamorphic Lens Top ViewWrong Position Calibrating Projector Input 2 DVI Main 17. TheaterMaster Remote Control for Vision 140/150Control Functions Navigating the Projector DisabledLtrbox night Vhd 720p16x9 night 4x3 nightInterlace Name 16x9 nightNumber Sync 26.97 kHz Input 23.98 Hz Menu Auto Source Locked Previous Channel Next ChannelNative aspect ratio is with the primary lens only. With an SupportSize and Position Menu Installation Picture Quality Menu Adjust Pixel Tracking before Pixel PhaseInternal grayscale test pattern Technicians use the White Balance submenuUncheck this item before exiting this menu There must be at least two consecutive white pixels presentRed White Level Back Porch Clipping Detector Color Enable RedAuto Color Enable Clamping Pre Calibration Red Black LevelLumaCal lamp calibration takes approximately two minutes Installation Menu Above, the Automatic Lens Calibration setting has no effect Factors Working With the LampValue only 1246 may represent 3500 lumens, for example Easily maintained as the lamp ages Installation 4Operation Using the On-Screen MenusAspect Ratio ISF PresetsService Input SourceMain Menu Input SourceAspect Ratio Hdtv programs in their Aspect Ratio SettingsDescription 169With a 2.351 screen and a RemotePicture Perform the adjustments in the order listed hereTypical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Typical Test Pattern for Adjusting SharpnessInformation ISF PresetsISF Night You must enter a passcode to access the Calibration menuCalibration Should be used by ISF-certified technicians onlyOperation Service You must enter a passcode to access the Service menuDo not change the Type setting in this menu Keystone Correction Vertical Keystone CorrectionHD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation 5Maintenance and Troubleshooting Lamp and Filter ReplacementLamp cover 2 screws Removing the Lamp RVR Removing the Primary Lens Lens ReplacementTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Trigger CineWide with SymptomVision 140/150 Error Codes Description GeneralLamp Failures Code Description Power and Cooling Code Description Code Description Miscellaneous Multiple serial commands Serial Command SyntaxRS-232 Connection and Port Configuration Serial CommandsAspect Ratio Commands Image Preset Commands Output Shift Commands Command Value Stored? Description Miscellaneous CommandsEnter key Serial Communications 7Specifications Vision 140/150 SpecificationsVision 140/150 Specifications Dimensions Home Theater Calibration SpecificationsIndustry-Standard Specifications Power Requirements VisionVHD Controller Specifications Vision 140/150 Dimensions Vision 140/150 DimensionsPage 020-0833-01 Rev. a March