Other Information
6. Remote Control Pass-through mode
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port.
RCU Pass-through Command description:
ENGLISH |
|
|
|
|
|
|
|
|
|
| ||
Command Type | Identify command type, |
|
|
| ||||||||
| Length |
| Total Byte of Message excluding “CR” |
|
| |||||||
| TV ID |
| Identification for each of TV |
|
|
| ||||||
|
|
|
| “p” (0x70h) : RCU |
|
|
| |||||
| Value[1~2] |
| Two bytes ASCII that defines the value |
|
| |||||||
| CR |
| 0x0D |
|
|
|
|
|
|
| ||
| RCU |
|
|
|
|
| ||||||
| Reply: (Command Type= “p”) |
|
|
|
|
| ||||||
| Name |
| Length |
| ID | Command |
| Value1 |
| Value2 | CR |
|
|
|
|
|
|
| Type |
|
|
|
|
|
|
| Byte Count |
| 1 Byte |
| 2 Byte | 1 Byte |
| 1 Byte |
| 1 Byte | 1 Byte |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bytes order |
| 1 |
| 2~3 | 4 |
| 5 |
| 6 | 7 |
|
| Example1: User press “Menu” Key form RCU to | |||||||||||
| to Server, then server will receive “1A”. |
|
|
|
|
| ||||||
| Reply (Hex Format) |
|
|
|
|
|
|
| ||||
| Name |
| Length |
| ID | Command |
| Value1 |
| Value2 | CR |
|
|
|
|
|
|
| Type |
|
|
|
|
|
|
| Hex |
| 0x36 |
| 0x30 | 0x70 |
| 0x31 |
| 0x41 | 0x0D |
|
|
|
|
|
| 0x33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| Example2: User press “5” Key form RCU to | |||||||||||
| Server, then server will receive “05”. |
|
|
|
|
| ||||||
| Reply (Hex Format) |
|
|
|
|
|
|
| ||||
| Name |
| Length |
| ID | Command |
| Value1 |
| Value2 | CR |
|
|
|
|
|
|
| Type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Hex |
| 0x36 |
| 0x30 | 0x70 |
| 0x30 |
| 0x35 | 0x0D |
|
|
|
|
|
| 0x36 |
|
|
|
|
|
|
|
Contact ViewSonic service team at: http://www.ViewSonic.com or call our service team: United States