OUTPUT TERMINALS
REMOTE Jack
You can use a
NOTE:
XThe functions not available on the VCR will not operate.
Remote control of the VCR is possible by connecting a remote controller with a circuit such as indicated below, to the REMOTE jack.
NOTES:
XUse a 3.5 mm
XThe connection should be done using a shielded cable no more than 5 meters long.
XThe functions not available on the VCR will not operate.
Remote control circuit
Remote control setting
The remote control switch 7 can be set to either eject the tape or access the menus.
1Press the MENU button until the (SET UP 1) menu is displayed.
@@@@@@@<SET@UP@1>
*DAYLIGHT@SET@@@@@USE
@@@@@@@@WEEK@MONTH@TIME
*CLOCK@SET
@@@ENGLISH
2Press the * (or +) button, until the “REMOTE” setting is flashing.
3Press the l (or j) button to select the desired switch mode.
EJECT . . . . . Switch 7 will eject the tape.
MENU. . . . . . Switch 7 will display the menu.
R0 1.2K
R1 0.3K
R2 0.43K
R3 0.51K
R4 0.62K
R5 0.75K
R6 0.91K
R7 1.1K
R8 1.3K
R9 2.0K
R10 2.4K
R11 3.6K
R12 5.6K
The resistance tolerance is 2% or less.
SW0: EJECT
SW1: STOP
SW2: STILL/PAUSE
SW3: REW
SW4: FF
SW5: PLAY
SW6: REC
SW7: EJECT (or MENU)
SW8: REV
SW9: REC/PLAY SPEED j, j
SW10: REC/PLAY SPEED l, l
SW11: SHIFT ], »
SW12: SHIFT «, «
4Press the SEARCH/AUDIO ON button to save the setting.
WARNING OUT Terminal
XIf the tape stops or other problem, the output becomes 0V (Low).
XTo reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.
Tape movement stop
Output reset
5V (H)
(Output impedance: 5.7 kΩ) 0V (L)
NOTE:
XIf the output is 0V (Low) due to the clog detect function, it can be reset by simply pressing the STOP button.
COM Terminal
XCommon GND (ground) terminal when connecting other terminals to external devices.
34 | English |