Sanyo TLS-9072 Output Terminals, Remote Jack, COM Terminal, Remote control setting

Page 35

OUTPUT TERMINALS

REMOTE Jack

You can use a VA-RMN01 Remote Control Unit (sold separately) to control remotely the VCR.

NOTE:

XThe functions not available on the VCR will not operate.

Remote control of the VCR is possible by connecting a remote controller with a circuit such as indicated below, to the REMOTE jack.

NOTES:

XUse a 3.5 mm mini-jack type plug.

XThe connection should be done using a shielded cable no more than 5 meters long.

XThe functions not available on the VCR will not operate.

Remote control circuit

Remote control setting

The remote control switch 7 can be set to either eject the tape or access the menus.

1Press the MENU button until the (SET UP 1) menu is displayed.

@@@@@@@<SET@UP@1>

*DAYLIGHT@SET@@@@@USE

@@@@@@@@WEEK@MONTH@TIME

@ON@@@1ST-SUN@@04@02:00 @OFF@@LST-SUN@@10@02:00

*CLOCK@SET @10-15-01@MON@@15:20:00 *REMOTE@@@@@@@@EJECT

*LANGUAGE-LANGUE-IDIOMA

@@@ENGLISH

2Press the * (or +) button, until the “REMOTE” setting is flashing.

3Press the l (or j) button to select the desired switch mode.

EJECT . . . . . Switch 7 will eject the tape.

MENU. . . . . . Switch 7 will display the menu.

R0 1.2K

R1 0.3K

R2 0.43K

R3 0.51K

R4 0.62K

R5 0.75K

R6 0.91K

R7 1.1K

R8 1.3K

R9 2.0K

R10 2.4K

R11 3.6K

R12 5.6K

The resistance tolerance is 2% or less.

SW0: EJECT

SW1: STOP

SW2: STILL/PAUSE

SW3: REW

SW4: FF

SW5: PLAY

SW6: REC

SW7: EJECT (or MENU)

SW8: REV

SW9: REC/PLAY SPEED j, j

SW10: REC/PLAY SPEED l, l

SW11: SHIFT ], »

SW12: SHIFT «, «

4Press the SEARCH/AUDIO ON button to save the setting.

WARNING OUT Terminal

XIf the tape stops or other problem, the output becomes 0V (Low).

XTo reset the output, press the STOP or ALL RESET button or unplug the power cord then plug it back in.

Tape movement stop

Output reset

5V (H)

(Output impedance: 5.7 kΩ) 0V (L)

NOTE:

XIf the output is 0V (Low) due to the clog detect function, it can be reset by simply pressing the STOP button.

COM Terminal

XCommon GND (ground) terminal when connecting other terminals to external devices.

34

English

Image 35
Contents TLS-9072 Location PrecautionsMoisture Condensation Problems For the customers in CanadaContents FeaturesAccessory Front Panel Locations of Controls and IndicatorsOFF indicator Locations of Controls and IndicatorsOperation Indicators Operation Mode IndicatorI H G F Back PanelConnections Power Cord InstallationON-SCREEN Menus ON-SCREEN Menus Timer SET menuAlarm Time menu Power FAILURE/DEW/USED Time menuLast 2 digits only are displayed Setting the Language and ClockSetting procedure is now completed Day of week is set automaticallyDate and time are displayed Changing the ON-SCREEN DisplaySelecting the On-screen Display Changing the Date/Time Display PositionVideo Cassette Tapes Correct tape thread check function Setting the Action to Take When a Cassette is LoadedVideo Cassette Tapes If tape management data is present on the tape Tape Management FunctionOperation If no tape management data is present on the tapeTape Management Function Setting the Tape Management FunctionConflict display sample Tape Management Conflict DisplayNormal Recording Before starting Recording Speed ModePause/Still indicator N blinks Normal RecordingConcerning the Number of Times Tapes can be Rerecorded on Changes to the Recording Speed Mode During RecordingAction to Take when the Video Signal Deteriorates Normal RecordingClog Detection Setting the Mode at the End of the TapeRecording Check Autorepeat Recording Repeat indicator will lightAlarm Mode setting is flashing Autorepeat RecordingAlarm Recording Setting Alarm RecordingChecking the Alarm Recordings Time Alarm RecordingAlarm Recording Counter Display Connections to the Alarm IN/OUT TerminalsAlarm Search Alarm ScanProgram Timer Recording Day of the week of the 8th line is flashing Program Timer RecordingTo Cancel all Program Timer Recordings Setting the HolidaysChanging a Program Timer Recording To Cancel a Program Timer RecordingThese portions will not be recorded Recording Using AN External Timer Input Normal Playback Field Advance Special PlaybackPicture Search Forward and Reverse Still ImageD Search 01 0000 will be displayed on screen DAY/TIME SearchDay/Time Search Is displayed on the digital display Setting the Security Lock Counter will be reset to 0H 00M 00S Tape Counter@@@@POWER@FAILURE Setting the BuzzerTape END OUT Terminal Tape END OUT Terminal Output SettingSW OUT Terminal Output Setting Output TerminalsCOM Terminal Remote control settingOutput Terminals Remote JackMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications Weekdays 830 AM 500 PM Pacific Time Sanyo Industrial VCR WarrantyRC4Q/NA