Sanyo DSR-M804P manual Normal RECORDING/TIMER Recording, Normal recording, Timer recording

Page 16

3NORMAL RECORDING/TIMER RECORDING

[TIMER] button

FULL indicator

[REC/STOP] button

 

Normal recording

Follow the steps below to record the monitored image onto the hard disk.

zWhen using the recorder for the first time, check that the TV SYSTEM selector switch on the rear panel is set to “PAL” correctly. If this switch is set incorrectly, recording will not be performed correctly. (JP. 8)

1 Press the [REC/STOP] button.

The REC/STOP indicator lights. “REC” appears on the screen, and recording starts.

Recording symbol

REC

HI

A

 

20 - 05 - 03 08 : 30 : 35

 

 

1

2

 

 

3

4

zWhen you record for the first time, the default settings are used. To change the image quality. (JP. 32)

zWhen the OVER WRITE recording setting is “ON”, the DVR starts recording from the beginning again. When it is “OFF” and the remaining space reaches zero, recording stops and the FULL indicator lights. (JP. 33)

zYou can record and play back images at the same time. (JP. 17)

zYou cannot change the menu during recording.

Ending normal recording

2 Press the [REC/STOP] button for about

3 seconds.

The REC/STOP indicator turns off and recording stops.

Timer recording

Follow the steps below to record the monitored image onto the hard disk at the set time.

1 Press the [TIMER] button.

The TIMER indicator lights, and the digital video recorder enters timer recording standby mode.

HI

A

20 - 05 - 03 08 : 30 : 35

1

2

3

4

zA warning tone sounds if timer recording has not been set.

(1) See P. 35 for how to set timer recording.

(2) When the time specified in the timer settings arrives, the REC/STOP indicator lights, “REC” appears in the screen, and recording starts.

(3) When the set end time arrives, the REC/STOP indicator turns off, and recording stops.

(4) The following restrictions apply to normal recording and timer recording.

z After making “PICTURE QUALITY” or “AUDIO RECORDING” menu settings and returning to the camera screen, recording does not start for a maximum of 6 seconds (although normal recording and timer recording operations can be made).

z After recording finishes (the REC/STOP indicator turns off), recording does not start for a maximum of 10 seconds (although normal recording and timer recording operations can be made).

zWhen the remaining memory space for recording reaches zero, recording stops, and the FULL indicator lights. You can start recording from the beginning again by changing the “OVER WRITE” setting. (JP. 33)

zYou can record and play back images at the same time. (JP. 17)

Stopping during timer recording

2 Press the [TIMER] button.

The TIMER indicator turns off and recording stops.

English

15

Image 16
Contents Page Precaution ServiceLocation Avoiding Electrical Shock and FireIntroduction Contents Contents Settings OtherInstallation conditions Before USEConditions to avoid Hard disk and cooling fan are expendable itemsBefore USE Names and Functions of Parts Front panelNames and Functions of Parts Rear panelInstallation and Connections Connecting a remote control circuitBasic connections System controller connectionsInstallation and Connections Connecting cables to the control and alarm terminalsConnecting to a network Connecting the power cordDisplayed symbols Screen Display and PositionOperation display area Example Normal screenScreen Display and Position Changing the position of the operation displayTo display the quad screen as single screens Press the QUAD/SEQUENCE buttonSetting the LANGUAGE/CLOCK When you have made a selection, press the buttonTo change the language Press the Menu buttonSetting the LANGUAGE/CLOCK Setting the timeTimer recording Normal RECORDING/TIMER RecordingNormal recording Alarm Recording Alarm recordingSet alarm recording When alarm input is detectedPlayback while fast-forwarding/rewinding PlaybackPress the PLAY/STOP button Normal RECORDING/TIMER Recording Playback Viewing still imagesFrame advance reverse To playback audioAlarm search Check that Alarm Search is selected, and press the buttonSearching for Recorded Images Image to search Search in Search screenSearching for Recorded Images Date/time searchPress the button, and set the date/ time to search Press the button to select VIEW, then press the buttonExample To search for the image from 26 October 2003 ViewSetting the key lock function Releasing the key lock functionDisplaying menu screens and setting screens Menu Configuration and OperationsTo restore menu setting items to their initial values Menu Configuration and Operations Overview of sub-menusBuzzer SET JP RS-485/NETWORK SET JPSummer Time settings Press the or button to change the settingLANGUAGE/CLOCK SET Select 1. LANGUAGE/CLOCK SET, and press the buttonWhen USE is selected for Mode under Summer Time EXT.CLOCK SET settingsLANGUAGE/CLOCK SET Switching HUB DVR Example 1 Displays screens in order of alarms Screen settingsScreen SET Menu Camera title setting Screen SET Menu Monitor SETSelect 2. Screen SET MENU, and press the button Select 1. Monitor SET, and press the buttonSetting the motion sensor Screen SET MenuSelect 2. Title SET, and press the button No.1 No.2 No.3 No.4Select 3. Motion Sensor SET, and press the button Setting sensor operation positionsMoving the cursor Setting items REC Mode SETRecorder Menu Select 3. Recorder MENU, and press the buttonResetting when the Full indicator lights Recorder MenuRecorder Menu Alarm REC Mode SET OLY AL-RC on TMRTimer recording settings Timer setting itemsAudio REC Level SET Select the channel and change sensitivitySelect 4. Timer REC SET and press the button Press the button onceSelect 4. Timer REC SET, and press the button Set the end Week and Stop time. Switch SET to onSetting timer reservations spanning more than 24 hours Example Timer recording from 1030 Monday to 2030 WednesdaySetting holidays After entering the setting, press the buttonInitializing the hard disk/adding a hard disk Select 5. Holiday SET, and press the buttonPress the or button to select HDD SET, then press the button Adding a hard disk 120 GB model onlyDisplay SET screen setting items SettingsDisplay SET Select 4. Display SET, and pressBuzzer SET Buzzer SET screen setting itemsSelect 5. Buzzer SET, and press the button Password setting example Security Lock SET screen setting itemsSetting passwords Security Lock SETSetting the user password Security Lock SETSetting the security lock To check the security lock, press any buttonNetwork connections and settings Settings for connecting to a PC or networkRS-485/NETWORK SET Select 7. RS-485/NETWORK SET, and press the buttonRS-485 connections and settings RS-485/NETWORK SETRS-485A RS-485BPower FAILURE/USED Time Select 8. Power FAILURE/USED TIME, and press the buttonPower DISK1 USEMenu UPLOAD/DOWNLOAD Select 9. Menu UPLOAD/ DOWNLOAD, and press the buttonMenu UPLOAD/DOWNLOAD To download menu itemsTo upload menu items Formatting CompactFlash cardsRS-485 specifications Interface SpecificationsRS-485 termination switch settings Interface Specifications DVR/VCR command tableSpecifications MPEG2Specifications Dimensions

DSR-M804P specifications

The Sanyo DSR-M804P is a versatile and efficient digital video recorder (DVR) designed specifically for professional applications, catering to a variety of surveillance needs. This compact unit stands out due to its robust features and advanced technologies, making it a reliable choice for monitoring and security.

One of the primary features of the DSR-M804P is its ability to support multiple video formats, including D1 resolution, which allows for high-quality video recording. The device can capture and store high-resolution images, ensuring that all details are clear and visible, which is essential for effective surveillance. The flexibility in video format support also facilitates integration with existing security systems, making it a suitable option for both new deployments and upgrades.

The DSR-M804P boasts real-time recording capabilities, allowing it to continuously capture video at high frame rates. This ensures that there are no gaps in surveillance footage, providing comprehensive coverage around the clock. Additionally, the DVR supports multi-channel inputs, enabling users to connect several cameras simultaneously. This feature is particularly beneficial in environments that require extensive monitoring, such as retail spaces, parking lots, or large facilities.

In terms of storage, the DSR-M804P is equipped with ample capacity, allowing for extended recording periods without the need for frequent manual intervention. The device supports various hard disk drive configurations, providing flexibility in storage options and ensuring that users can choose a setup that meets their specific requirements.

The user interface of the DSR-M804P is designed for ease of use, featuring intuitive controls that allow for simple navigation through settings and recorded footage. The system also includes options for remote access, enabling users to view live footage and recordings from virtually anywhere, which enhances the overall functionality and convenience of the device.

Another notable characteristic of the DSR-M804P is its compatibility with advanced technologies such as motion detection and alarm triggering. These features optimize surveillance by ensuring that only relevant footage is recorded, thus conserving storage space and making it easier to review critical events.

Overall, the Sanyo DSR-M804P is a highly capable digital video recorder that offers a blend of high-quality video capture, flexible storage options, and user-friendly operation, making it an ideal choice for various professional surveillance applications.