Sanyo DSR-M804P manual Audio REC Level SET, Timer recording settings, Timer setting items

Page 36

3RECORDER MENU

4 Press the [ ] or [ ] button to select the desired item, then press the [ ] button.

The setting flashes.

5 Press the [ ] or [ ] button to change the setting, then press the [ ] button.

6 Repeat procedures 4 to 5 to set other items as needed.

7 When you have finished making the settings, press the [EXIT/OSD] button.

The display returns to the normal screen.

AUDIO REC LEVEL SET

1 Press the [MENU] button.

The [MENU] button lights, and the <MAIN MENU> screen is displayed.

2 Select “3. RECORDER MENU”, and press the [ ] button.

The <RECORDER MENU> screen is displayed.

3 Press the [ ] or [ ] button to select “3. AUDIO REC LEVEL SET”, then press the [ ] button.

The <AUDIO REC LEVEL SET> screen is displayed.

4 Select the channel and change sensitivity

Each time you press the [ ] button, the display switches between possible channels. The sensitivity marks on the screen flashes for the selected channel.

To increase level: Use the [ ] button.

To decrease level: Use the [ ] button.

zMany sensitivity marks indicate high sensitivity.

5 When you have finished making the settings, press the [EXIT/OSD] button.

The display returns to the normal screen.

Timer recording settings

[MENU] button [ ] button [ ] button

[ ] button [ ] button [EXIT/OSD] button

Timer setting items

You can use the timer functions to set recording start/stop

times.

(1) (2) (3) (4)

(5)

You can set times at which to start and stop recording on each specified day of the week.

(1)WEEK:

Used to select the days of the week for timer settings. When each day in the “WEEK” column is flashing, it can be set to other days. The lines 7 (initially “SAT”) and 8 (initially “DLY”) are used for timer recording settings spanning more than 24 hours.

(2)START:

Enter the time at which to start timer recording.

(3)STOP:

Enter the time at which to stop timer recording.

(4)SET:

Setting “ON” enables the entered timer recording setting.

Setting “OFF” disables the entered timer recording setting.

(5)SAT, DLY:

Use these lines for timer recording spanning more than 24 hours.

English

35

Image 36
Contents Page Precaution ServiceLocation Avoiding Electrical Shock and FireIntroduction Contents Contents Settings OtherInstallation conditions Before USEConditions to avoid Hard disk and cooling fan are expendable itemsBefore USE Names and Functions of Parts Front panelNames and Functions of Parts Rear panelInstallation and Connections Connecting a remote control circuitBasic connections System controller connectionsInstallation and Connections Connecting cables to the control and alarm terminalsConnecting to a network Connecting the power cordDisplayed symbols Screen Display and PositionOperation display area Example Normal screenScreen Display and Position Changing the position of the operation displayTo display the quad screen as single screens Press the QUAD/SEQUENCE buttonSetting the LANGUAGE/CLOCK When you have made a selection, press the buttonTo change the language Press the Menu buttonSetting the LANGUAGE/CLOCK Setting the timeNormal RECORDING/TIMER Recording Timer recordingNormal recording Alarm Recording Alarm recordingSet alarm recording When alarm input is detectedPlayback Playback while fast-forwarding/rewindingPress the PLAY/STOP button Normal RECORDING/TIMER Recording Playback Viewing still imagesFrame advance reverse To playback audioAlarm search Check that Alarm Search is selected, and press the buttonSearching for Recorded Images Image to search Search in Search screenSearching for Recorded Images Date/time searchPress the button, and set the date/ time to search Press the button to select VIEW, then press the buttonExample To search for the image from 26 October 2003 ViewSetting the key lock function Releasing the key lock functionMenu Configuration and Operations Displaying menu screens and setting screensTo restore menu setting items to their initial values Menu Configuration and Operations Overview of sub-menusBuzzer SET JP RS-485/NETWORK SET JPSummer Time settings Press the or button to change the settingLANGUAGE/CLOCK SET Select 1. LANGUAGE/CLOCK SET, and press the buttonEXT.CLOCK SET settings When USE is selected for Mode under Summer TimeLANGUAGE/CLOCK SET Switching HUB DVR Screen settings Example 1 Displays screens in order of alarmsScreen SET Menu Camera title setting Screen SET Menu Monitor SETSelect 2. Screen SET MENU, and press the button Select 1. Monitor SET, and press the buttonSetting the motion sensor Screen SET MenuSelect 2. Title SET, and press the button No.1 No.2 No.3 No.4Setting sensor operation positions Select 3. Motion Sensor SET, and press the buttonMoving the cursor Setting items REC Mode SETRecorder Menu Select 3. Recorder MENU, and press the buttonResetting when the Full indicator lights Recorder MenuRecorder Menu Alarm REC Mode SET OLY AL-RC on TMRTimer recording settings Timer setting itemsAudio REC Level SET Select the channel and change sensitivitySelect 4. Timer REC SET and press the button Press the button onceSelect 4. Timer REC SET, and press the button Set the end Week and Stop time. Switch SET to onSetting timer reservations spanning more than 24 hours Example Timer recording from 1030 Monday to 2030 WednesdaySetting holidays After entering the setting, press the buttonInitializing the hard disk/adding a hard disk Select 5. Holiday SET, and press the buttonPress the or button to select HDD SET, then press the button Adding a hard disk 120 GB model onlyDisplay SET screen setting items SettingsDisplay SET Select 4. Display SET, and pressBuzzer SET screen setting items Buzzer SETSelect 5. Buzzer SET, and press the button Password setting example Security Lock SET screen setting itemsSetting passwords Security Lock SETSetting the user password Security Lock SETSetting the security lock To check the security lock, press any buttonNetwork connections and settings Settings for connecting to a PC or networkRS-485/NETWORK SET Select 7. RS-485/NETWORK SET, and press the buttonRS-485 connections and settings RS-485/NETWORK SETRS-485A RS-485BPower FAILURE/USED Time Select 8. Power FAILURE/USED TIME, and press the buttonPower DISK1 USEMenu UPLOAD/DOWNLOAD Select 9. Menu UPLOAD/ DOWNLOAD, and press the buttonMenu UPLOAD/DOWNLOAD To download menu itemsTo upload menu items Formatting CompactFlash cardsInterface Specifications RS-485 specificationsRS-485 termination switch settings Interface Specifications DVR/VCR command tableSpecifications MPEG2Specifications Dimensions

DSR-M804P specifications

The Sanyo DSR-M804P is a versatile and efficient digital video recorder (DVR) designed specifically for professional applications, catering to a variety of surveillance needs. This compact unit stands out due to its robust features and advanced technologies, making it a reliable choice for monitoring and security.

One of the primary features of the DSR-M804P is its ability to support multiple video formats, including D1 resolution, which allows for high-quality video recording. The device can capture and store high-resolution images, ensuring that all details are clear and visible, which is essential for effective surveillance. The flexibility in video format support also facilitates integration with existing security systems, making it a suitable option for both new deployments and upgrades.

The DSR-M804P boasts real-time recording capabilities, allowing it to continuously capture video at high frame rates. This ensures that there are no gaps in surveillance footage, providing comprehensive coverage around the clock. Additionally, the DVR supports multi-channel inputs, enabling users to connect several cameras simultaneously. This feature is particularly beneficial in environments that require extensive monitoring, such as retail spaces, parking lots, or large facilities.

In terms of storage, the DSR-M804P is equipped with ample capacity, allowing for extended recording periods without the need for frequent manual intervention. The device supports various hard disk drive configurations, providing flexibility in storage options and ensuring that users can choose a setup that meets their specific requirements.

The user interface of the DSR-M804P is designed for ease of use, featuring intuitive controls that allow for simple navigation through settings and recorded footage. The system also includes options for remote access, enabling users to view live footage and recordings from virtually anywhere, which enhances the overall functionality and convenience of the device.

Another notable characteristic of the DSR-M804P is its compatibility with advanced technologies such as motion detection and alarm triggering. These features optimize surveillance by ensuring that only relevant footage is recorded, thus conserving storage space and making it easier to review critical events.

Overall, the Sanyo DSR-M804P is a highly capable digital video recorder that offers a blend of high-quality video capture, flexible storage options, and user-friendly operation, making it an ideal choice for various professional surveillance applications.