Alloy Computer Products POE120 Series manual SC/ST Converter Models

Page 8

9. DIP Switch Configuration

Fig. 11 Reset button and S1 – Bit 1, 2, 3, 4, 5, 6, Configuration and Settings

Reset

: If S1-1, S1-2, S1-3, S1-4 or S1- status is

 

 

 

changed, please press this button for your

 

 

 

settings to take effect.

S1-1 TP Port Mode

:

AUTO(Default) or FORCE

S1-2

TP Port Speed

: 100 or 10 when TP at Force

S1-3

TP Port Duplex

: FDX or HDX when TP at Force

S1-4 LFP

: LFP Enabled (Default) or Disabled

S1-5

Fibre Port Duplex

: 100FDX (Default) or 100HDX

S1-6 POE ON/OFF

:

Enabled (Default) or Disabled

Note:

1.S1-2 and S1-3 will take effect only when S1-1 is set to TP-Force

2.S1-5 must be set to 100FDX for Single Fibre Model

3.S1-6 must be set to POE when you need to supply power to a PD.

Warning:

-When a Copper port set to AUTO and is connected to a device that is Forced to 100Mbps FDX , instead of a device running NWAY, it may result in the devices connecting in HDX mode, this may cause packet collisions on your network.

-Please ensure that all network nodes that this device connects to are set to the same mode at each end of the link.

e.g., Both ends are set to Auto-Negotiation mode (AUTO)

10.Cable Distances and Limitations

-TP Cable Limitations: Cat 5 up to 100m

-Fibre Cable Limitations:

SC/ST Converter Models

Multi Mode Half Duplex

412m

Multi Mode Full Duplex

2Km

Single Mode Half Duplex

412m

Single Mode Half Duplex

5/20/40/60/80/100Km

Image 8
Contents POE120 Series Single Fibre Model TX, RX Wavelength Model100Mbps Fibre Transceiver Port Default AutoFibre Default 100FDX Port POE120 Series to PSE Device or POE Injector Pairs used for receiving power over Ethernet Cable WDM Single Fibre ModelLink Failure Propagation Normal Status via a pair of LFP’sColour Function DC Jack and AC-DC Power ConverterLED Description SC/ST Converter Models Technical Specifications Standards Power ReceptionLED Indicators Power Requirements