AMX AXB-REL8 Connection and Wiring, Setting the Device Dip Switch, Wiring Requirements

Page 7

Connection and Wiring

Connection and Wiring

Setting the DEVICE Dip Switch

The eight-position Device DIP switch is located on the front panel of the AXB-REL8 as shown in FIG. 1 on page 1. Each device in the AXlink bus must have a unique AXlink device number.

If you later change the device number, remove and reconnect the AXlink connector. This enters the new device number into memory. The device number takes effect only on power-up.

The device can be 1 of the 255 devices in an Axcess, AXCENT, AXCENT2, or AXCENT3 system. The device number must match the device assignment in the Axcess program. AMX assigns device numbers into the following three segments:

!

Cards

1 through 95

 

!

Boxes

96 through 127

!

Panels

128 through

255

Set the device number by setting the DEVICE DIP switch. The device number is the total of all of the switches in the ON (down) position. The following table shows the switch numbers and their corresponding values.

Device DIP switch settings

Position

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

As an example, the following DIP switch (FIG. 2) defines the AXB-REL8 as device number 97 (1 + 32 + 64 = 97).

DEVICE

ON

1 2 3 4 5 6 7 8

FIG. 2 Example device DIP switch with value of 97

Set the AXB-REL8 device number before connecting AXlink wiring. Do not install relay wiring at this time.

Wiring Requirements

The AXB-REL8 uses a four-pin AXlink Central Controller connector for power and data. If the distance between the AXB-REL8 and the Central Controller exceeds power consumption limits, you must connect an optional 12 VDC power supply. Refer to the following section for more information.

AXB-REL8 Axcess Relay Controller

3

 

 

 

 

Image 7
Contents AXB-REL8 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Front and Rear Panels SpecificationsSpecifications Product InformationFront Panel Components Device DIP switch settings Connection and WiringSetting the Device Dip Switch Wiring RequirementsWiring Guidelines at 170 mA Connecting the WiringPreparing captive wires Wiring guidelinesRelay connections AXlink data and power connectionsWiring AXlink with optional 12 VDC power supply Checking the installationRack-Mounting the AXB-REL8 optional Testing the installationAXB-REL8 System Worksheet and Installation GuideAMX reserves