Perle Systems S-100-XXXXX manual Powering up the Perle Media Converter, Operation

Page 9

Powering up the Perle Media Converter

Connect the Perle supplied power adapter to the media converter.

Turn on the power at source.

Check that the PWR LED light is lit and on solid.

Operation

Status LED

The Perle Fast Ethernet Media converters have three single color status LEDs located on the front panel of the unit.

PWR - Power/Test

On: Power is on and in normal operation.

Blinking slowly: the unit is in loopback mode.

Blinking quickly: the unit has a hardware error.

LKF - Fiber Link/Activity

On: Fiber link present.

Blinking quickly: Fiber link present and receiving data.

Off: No fiber link present.

LKC - Copper Link/Activity

On: Copper link is present.

Blinking quickly: Copper link present and receiving data.

Off: No copper link present.

Fast Ethernet Media Converter – Installation Guide 9

Image 9
Contents Perle Fast Ethernet Media Converters Overview Auto Mdix Jumper Settings InstallationDIP Switches DIP Switch SettingsAuto Negotiation Switch Switch Position Mode Far End Fault Switch Switch Position Mode Link Mode Switch Switch PositionUnused Switch Loopback Switch Switch Position Mode Pause Switch Switch Position ModeInstalling the Duplex Fiber Cable Installing the Simplex Fiber CableInstalling the Copper Cable Operation Powering up the Perle Media ConverterAuto-MDIX Error RecoveryGeneral TroubleshootingNo connectivity MethodTechnical Specifications Ethernet Copper Cabling Requirements Fiber Cabling RequirementsCompliance Information EN 55022 Class B EN 55024 Class a Laser Safety IECWarranty / Registration Contacting Technical SupportCopyright