Iomega EP510 Explosion & DUST-IGNITION Proof Certifications, Nema 4X, Replacement Cover O-RINGS

Page 8

AM-4109/1104 IP510, EP510, IP511, EP511 SERIES

EXPLOSION & DUST-IGNITION PROOF CERTIFICATIONS

FACTORY MUTUAL and CANADIAN STANDARDS ASSOCIATION

WARNING: The following ratings are valid ONLY WHEN the cover is installed for FM and CSA. BOTH the cover and the locking device, using tamper resistant screws must be installed. Screws are to be removed and installed with a special driver bit (supplied). In case of a need for replacement parts, follow TABLE 4.

EXPLOSION PROOF FOR CLASS I, DIV 1, GROUP B, C, D.

DUST-IGNITION PROOF FOR CLASS II, DIV 1, GROUP E, F, G.

SUITABLE FOR CLASS III LOCATIONS.

TABLE 3: NEMA 4X, REPLACEMENT COVER O-RINGS

PART NAME

PART NUMBER

O-RING SEAL, VITON

214-649-000-242

O-RING SEAL, BUNA-N

214-649-000-240

 

 

TABLE 4: NEMA 4X, REPLACEMENT PARTS FOR COVER LOCKING DEVICE

PART NAME

PART NUMBER

LOCKING CLAMP

224-669-000-016

TAMPER-PROOF SCREW

214-648-000-401

DRIVER BIT

010132-000

8

Image 8
Contents EP510, IP510, EP511, IP511 Series Servicing North America Contents AIR Connections SupplyOutput GaugeMounting General Direct MountingDirections Electrical ConnectionsTerminal Block Transducer Models CalibrationPneumatic Maintenance MaintenanceElectrical Maintenance Enclosures Entity ParametersNonincendive Nema 4X, Replacement Cover O-RINGS Nema 4X, Replacement Parts for Cover Locking DeviceExplosion & DUST-IGNITION Proof Certifications Part Name Part NumberKits KIT Name511 Series I/P and E/P Transducer Specifications WARRANTY/DISCLAIMER Temperature