Omega Engineering RD8900 user manual Timer1, Timer2, Totalizer

Page 42

An example of Totalizer: A factory operates for 8 hours a day, and the staff wish to get the total volume of production from daily, weekly and monthly reports. First, the user needs to enter into Tools mode, do the settings as follows, then totalizer starts to work from 8:30 am, and stops at 17:30 pm daily. After production has finished, the user does the following: press Event key on the left hand side, and press Mode key to select Report mode. Finally, press Report key to choose daily, weekly or monthly report.

Timer1

 

 

 

Type: Daily

 

Action: Enable

 

Time - Hour: 8

Min: 30

 

 

Job1: Reset Totalz

Target: Tolz1

 

Job2: Enable Totalz

Target: Tolz1

 

Timer2

 

 

 

Type: Daily

 

Action: Enable

 

Time - Hour: 17

Min: 30

 

 

Job1: Disable Totalz

Target: Tolz1

 

Job2: Log Report

Target: Tolz1

 

Totalizer

 

 

 

Name: xxxx

 

Desc : xxxxxxxxxxxxxxxxx

 

Source: AI1

 

Action: Enable

Decimal: 1

Period: Min

 

Unit: xxxx

Preset: 0.0

Event

 

 

 

 

No

Type

Setpoint

Job1

Job2

1

Hi

xxxx

Log Alarm

Set DO on

2

Low

xxxx

Log Alarm

Set DO off

The Weekly Report shows the following information:

The week’s production volume: Monday: 990, Tuesday: 1010, Wednesday: 1020, Thursday:

1020, Friday: 980 respectively. The weekly report shows production volume 5,020.

42

Image 42
Contents Paperless Recorder RD8900 Contents SafetySystem Info Safety Safety SymbolsProtective Earth DC Supply Safety Notes and Precautions To replace the power-line fuse Static ElectricityExpandable Input and Output Cards Unique features of recorderGeneral Description CommunicationStorage Media CF Card Data SecurityInfrared Detector IR Detector Ordering codes and accessories Ordering codes RD8900 耟- 耟- 耟 Accessories DescriptionDisplay SpecificationsPower MemoryDigital Input Card DI181 Comm Module CM181Standard Ethernet Communication Infrared Detector Environmental & PhysicalApproval Standards Unpacking Installation and wiringInstallation Panel mounting stylePage Bench top / Portable style Page Page Page Figure耟2 Setup input, output & 24VDC power supply cards Analog input card part numbers AI181, AI182, AI183VDC auxiliary power supply card AP181 Wiring for the cards Figure耟2 Digital output card DO181 Figure耟2 VDC auxiliary power supply card AP181 RS-232, RS-422, RS-485 wiring Installation of Compact Flash CF card Basic Operation Soft keysMode HistoryEvent/Alarm EventStatus ExitReport Operate DumpClear ShutdownPage Configuration Channel Scale EventPage Display Page Tools Timer, Counter & Totalizer TimerCounter Totalizer Timer1 Timer2Totalizer Instrument InstrumentStorageMedia Communication RS-232, RS-485Ethernet Clock System Info Configuration example DemoHardware requirements Set upPC software Observer I PC Software manual HelpPage How to use PC software Page Mathematics Math Expressions and an exampleExpressions on recorder Mathematics Functions An example of Math Omega Engineering, INC