Omega Engineering RD8900 user manual Accessories, Description

Page 9

8Storage Media

1:16MB Compact Flash card ( CF )

3:128 MB CF card

X:other options

9Case/Mounting

1:standard Panel Mounting

2:Bench top / Portable style with handle

10Special Option:

0:none

1:24VDC auxiliary power supply ( for transmitter, 6 channels )

2:3-channel analog output

3:6-channel analog output

4:

9-channel analog output

X: other options

Accessories:

 

 

Part no.

 

Description

 

AI181, AI182, AI183

1, 2, 3-channel analog input card (TC, RTD, mA, voltage )

AI181V, AI182V, AI183V 1, 2, 3-channel voltage input card (+, - voltage only)

DI181

6-channel digital input card

 

DO181

6-channel relay output card ( AC/DC )

 

CM181

RS-232/422/485 + Ethernet COMM module

CM182

Standard Ethernet COMM module

 

PM181

90-250 VAC, 47-63 Hz power supply

 

PM182

11-18 VDC power supply module

 

PM183

18-36 VDC power supply module

 

AP181

24 VDC auxiliary power supply card for 6 transmitters

MK183

bench top / portable handle assembly kit

CF016

16MB compact flash card

 

CF064

64MB compact flash card

 

CF128

128MB compact flash card

 

AS181

Basic PC software Observer I

 

AS182

Extensive PC software Observer II

 

UMVR181

User’s Manual

 

BT181

Boot ROM without Math, Counter & Totalizer

BT182

Boot ROM with Math, Counter & Totalizer

SC181

Slot cover for vacant slot

 

SNA10A

RS-485 to RS-232 converter

 

AO183

3-channel analog output card

 

Notes:

The rear Slots of the recorder will only accept up to 6 optional cards of input, output or 24 VDC power supply. For example, 12-channel analog input needs 4 pcs. of 3-channel analog input card AI183. Now it is left 2 empty Slots for other cards.

The basic PC software Observer I is supplied free together with recorder. There is an additional charge for the extensive PC software Observer II supplied with communication of RS-232/422/485 or Ethernet.

9

Image 9
Contents Paperless Recorder RD8900 Safety ContentsSystem Info Safety Safety SymbolsProtective Earth DC Supply Safety Notes and Precautions Static Electricity To replace the power-line fuseGeneral Description Unique features of recorderExpandable Input and Output Cards CommunicationStorage Media CF Card Data SecurityInfrared Detector IR Detector Ordering codes and accessories Ordering codes RD8900 耟- 耟- 耟 Description AccessoriesPower SpecificationsDisplay MemoryDigital Input Card DI181 Comm Module CM181Standard Ethernet Communication Infrared Detector Environmental & PhysicalApproval Standards Installation Installation and wiringUnpacking Panel mounting stylePage Bench top / Portable style Page Page Page Figure耟2 Analog input card part numbers AI181, AI182, AI183 Setup input, output & 24VDC power supply cardsVDC auxiliary power supply card AP181 Wiring for the cards Figure耟2 Digital output card DO181 Figure耟2 VDC auxiliary power supply card AP181 RS-232, RS-422, RS-485 wiring Installation of Compact Flash CF card Soft keys Basic OperationHistory ModeEvent Event/AlarmStatus ExitReport Clear DumpOperate ShutdownPage Configuration Channel Event ScalePage Display Page Timer Tools Timer, Counter & TotalizerCounter Totalizer Timer1 Timer2Totalizer Instrument InstrumentStorageMedia Communication RS-232, RS-485Ethernet Clock System Info Demo Configuration examplePC software Observer I Set upHardware requirements PC Software manual HelpPage How to use PC software Page Mathematics Math Expressions and an exampleExpressions on recorder Mathematics Functions An example of Math Omega Engineering, INC