Omega Engineering RD8900 user manual Installation and wiring, Unpacking, Panel mounting style

Page 13

2. Installation and wiring

2.1 Unpacking

If any damage is found while unpacking, the user should contact the local representative at once. It is suggested that the special packaging is retained for possible future requirement.

2.2 Installation

Remove stains from this equipment using a soft, dry cloth. Don’t use harsh chemicals, volatile solvent such as thinner or strong detergents to clean the equipment in order to avoid deformation or decoloration.

The recorder is designed for indoor use and not in any hazardous area. It should be kept away from shock, vibration, and electromagnetic fields such as variable frequency drives, motors and transformers.

It is intended to be operated in the following environment:

Pollution Degree Level II

IEC1010-1( EN61010-1 )

Temperature

5 ~ 50 ˚C

 

Humidity

20 ~ 80 % RH ( non-condensing )

Power

90 ~ 250 VAC, 50/60 Hz

 

11-18 VDC or 18 - 36 VDC

Panel mounting style

The front side

Figure 2 - 1

13

Image 13
Contents Paperless Recorder RD8900 Safety ContentsSystem Info Safety Symbols SafetyProtective Earth DC Supply Safety Notes and Precautions Static Electricity To replace the power-line fuseGeneral Description Unique features of recorderExpandable Input and Output Cards CommunicationData Security Storage Media CF CardInfrared Detector IR Detector Ordering codes and accessories Ordering codes RD8900 耟- 耟- 耟 Description AccessoriesPower SpecificationsDisplay MemoryComm Module CM181 Digital Input Card DI181Standard Ethernet Communication Environmental & Physical Infrared DetectorApproval Standards Installation Installation and wiringUnpacking Panel mounting stylePage Bench top / Portable style Page Page Page Figure耟2 Analog input card part numbers AI181, AI182, AI183 Setup input, output & 24VDC power supply cardsVDC auxiliary power supply card AP181 Wiring for the cards Figure耟2 Digital output card DO181 Figure耟2 VDC auxiliary power supply card AP181 RS-232, RS-422, RS-485 wiring Installation of Compact Flash CF card Soft keys Basic OperationHistory ModeEvent Event/AlarmExit StatusReport Clear DumpOperate ShutdownPage Configuration Channel Event ScalePage Display Page Timer Tools Timer, Counter & TotalizerCounter Totalizer Timer2 Timer1Totalizer Instrument InstrumentStorageMedia RS-232, RS-485 CommunicationEthernet Clock System Info Demo Configuration examplePC software Observer I Set upHardware requirements PC Software manual HelpPage How to use PC software Page Math Expressions and an example MathematicsExpressions on recorder Mathematics Functions An example of Math Omega Engineering, INC