Panasonic TH-42PF11UK manual Sync, SDI Through, Input signal display, Setting RGB sync signal

Page 43

SET UP for Input Signals

SYNC

Select SIGNAL from the “SET UP” menu during RGB input signal.

Press to select the “SYNC”.

Press to adjust.

 

SIGNAL

[ RGB ]

 

 

 

 

 

SYNC

AUTO

 

 

 

 

 

 

3 : 2 PULLDOWN

OFF

 

 

 

 

 

 

XGA MODE

1024 × 768

 

Setting RGB sync signal

Confirm that the input is set to RGB INPUT (this setting is valid only for RGB INPUT signal).

AUTO:

The H and V sync or synchronized signal are automatically selected.

 

If both input, it is selected the H and V sync.

ON G:

Uses a synchronized signal on the Video G signal, which is input from

 

the G connector.

VBS:

Uses a synchronized signal of Composite Sync input, which is input

 

from the HD connector.

SYNC

AUTO

SYNC

ON G

SYNC

VBS

SDI THROUGH

Set the active through function of the Dual Link HD-SDI Terminal Board (TY-FB11DHD).

Note:

Settings can only be performed for this menu when a slot mounted with a Dual Link HD-SDI Terminal Board (TY-FB11DHD) is selected.

Press to select the “SDI THROUGH”.

Press to select “ON” or “OFF”.

ON: Enables active through. OFF: Disables active through.

 

SIGNAL

[ Digital ]

 

 

 

 

 

3 : 2 PULLDOWN

OFF

 

 

 

 

 

 

SDI THROUGH

OFF

 

 

 

 

 

REFRESH RATE

100 Hz

 

 

 

 

 

 

NOISE REDUCTION

OFF

 

Input signal display

Displays the frequency and the type of the current input signal.

This display is valid only for COMPONENT/RGB/PC and Digital input signal.

Display range:

 

 

Horizontal

15

- 110 kHz

Vertical

48

- 120 Hz

The dot clock frequency is displayed during digital signal input.

H-FREQ. 63.98 kHz

V-FREQ. 60.02 Hz SIGNAL FORMAT 1280×1024/60

H-FREQ. 63.98 kHz

V-FREQ. 60.02 Hz

DOT CLOCK FREQ. 108.0 MHz

SIGNAL FORMAT 1280×1024/60

43

Image 43
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits When using the Plasma Display Safety PrecautionsAC Power Supply Cord MaintenanceSafety Precautions / Maintenance SetupAccessories Supplied AccessoriesRemote Control Batteries Secure any excess cables with band as required ConnectionsAC cord fixing Cable fixing bandPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Communication parameters Signal names for D-sub 9P connectorCommand Serial Terminals connectionDVD Hdmi connectionComponent / RGB connection RCA-BNCConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet OSD Language Power on / OFFWhen first switching on the unit Present Time SetupINPUT1 INPUT2A INPUT2B INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageMenu Screen on / OFF Remote control sensor Volume AdjustmentMain Power On / Off Switch Power Indicator Basic ControlsOn OFF Basic ControlsAspect Controls All Aspect modePanasonic Auto During Advanced PIP Selecting the Display ModeAspect Controls During PIPTransparent Function Insertion Function Swapping ScreensDuring Blend PIP Composite Screen Function Transparent Function and Insertion FunctionSelecting the Sub Screen Position During P in P Display Selecting the Target Screen for OperationsOperations on Main screen Sub screen Select the magnification required for the enlarged display Digital ZoomDisplay the operation guide Select the area of the image to be enlargedOn-Screen Menu Display Adjusting POS. /SIZE OFF On Left On Center On Right Adjusting POS. /SIZEAdjusted as follows For 2k1k signals 2k1kCinema Picture AdjustmentsStandard DynamicPicture Adjustments Advanced SettingsSDI Sound Output Sound AdjustmentSET UP Timer Present Time SetupScreensaver For preventing image retention Setup of Screensaver TimeMode selection Start settingOFF Dark MID Bright Side BAR AdjustReduces screen image retention Screensaver For preventing image retentionReduces power consumption Addition sign Selected Input Customizing the Input labelsLandscape Portrait × 1 2 × SET UP for Multi DisplayHow to setup Multi Display Display Number locations for each arrangement ExamplesID Cancellation ID Remote Control FunctionSET UP for Multi Display ID remote control button operationInsert Level Transparent Display of the Sub Screen During Blend PIPSub Screen Insertion During Blend PIP PIP Advanced PIP Blend PIPHow to setup Portrait SET UP for PortraitPress to select the Portrait Setup Undisplayed area 48 dots SET UP for PortraitPress twice to exit from SET UP Viewing Area LocationComponent / RGB in Select SET UP for Input SignalsYUV / RGB in Select SET UP for Input Signals Signal menu3D Y/C Filter For Ntsc AV images Color System XGA ModeColor System / Panasonic Auto PulldownAdvanced NR Press to adjustRefresh Rate Noise ReductionSDI Through Input signal displaySetting RGB sync signal SyncOptions1/3 Options AdjustmentsINPUT1 INPUT2 INPUT3 Options AdjustmentsNormalization DelayProgram Edit screen Weekly Command TimerPress Action button Program numberShipping condition Plasma Display panel TroubleshootingFull List of Aspect ModesApplicable Input Signals VGA60 Applicable Input SignalsVideo input Hdmi MHz Active pixels Pixels Active lines LinesCommand list of Weekly Command Timer TH-42PF11UK TH-50PF11UK SpecificationsTH-58PF11UK TH-65PF11UK SpecificationsFor the U.S.A and Puerto Rico Panasonic Professional Flat Panel Display Limited WarrantyFor Canada Limited Warranty StatementPage Panasonic Canada Inc Customer’s RecordPanasonic Professional Display Company Executive Office