Panasonic TH-37PH10UK manual SET UP for Input Signals, Component / RGB in Select, Component RGB

Page 36

SET UP for Input Signals

COMPONENT / RGB IN SELECT

Select to match the signals from the source connected to the COMPONENT / RGB input terminals. Y, PB, PR signals “COMPONENT”

R, G, B, HD, VD signals “RGB”

1

Press to display the SET UP menu.

2

Press to select the “COMPONENT / RGB-IN

 

 

SELECT”.

Press to select the desired mode.

COMPONENT RGB

3 Press to exit from adjust mode.

Notes:

Selection may not be possible, depending on which optional board is installed.

Make setting of the selected input terminal (SLOT1, SLOT2, SLOT3 or PC IN). (Setting of SLOT3 is not available on TH-37PH10UK.)

SET UP

1/2

SIGNAL

 

COMPONENT/RGB-IN SELECT

 

RGB

INPUT LABEL

PC

POWER SAVE

OFF

STANDBY SAVE

OFF

POWER MANAGEMENT

OFF

AUTO POWER OFF

OFF

OSD LANGUAGE

ENGLISH (US)

3D Y/C FILTER – For NTSC AV images

Select “SIGNAL” from the “SET UP” menu during VIDEO (S VIDEO) input signal mode. (“SIGNAL [VIDEO]” menu is displayed.)

1

Press to select the “3D Y/C FILTER (NTSC)”.

 

Press to set ON / OFF.

2

Press to exit from adjust mode.

Note:

When ON, this setting only affects NTSC input signals.

SET UP

1/2

SIGNAL

 

COMPONENT/RGB-IN SELECT

 

RGB

INPUT LABEL

PC

POWER SAVE

OFF

STANDBY SAVE

OFF

POWER MANAGEMENT

OFF

AUTO POWER OFF

OFF

OSD LANGUAGE

ENGLISH (US)

Press ACTION () button

 

SIGNAL

[ VIDEO ]

 

 

 

 

 

3D Y/C FILTER (NTSC)

ON

 

 

 

 

 

COLOR SYSTEM

AUTO

 

 

 

 

 

 

3 : 2 PULLDOWN

OFF

 

 

 

 

 

 

Panasonic AUTO (4 : 3)

NORMAL

 

 

 

 

 

 

VIDEO NR

OFF

 

 

 

 

 

36

Image 36
Contents Operating Instructions Manual de instrucciones English EspañolModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Statement Trademark CreditsSafety Precautions When using the Plasma DisplayMaintenance Safety Precautions / MaintenanceSetup AC Power Supply CordAccessories Accessories SuppliedRemote Control Batteries Connections SpeakersAC cord fixing Signal Names for Mini D-sub 15P Connector PC Input Terminals connectionConnections Command Serial Terminals connectionCommunication parameters Basic format for control dataRGB signal R, G, B AV & Component / RGB connectionPower on / OFF Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Fix the AC cord plug securely to the Plasma Display. seeBasic Controls Basic Controls VA N C E D Settings On-Screen Menu DisplaysTime / Power OFF Time On Time / Power OFFOn-Screen Menu Displays Selecting the input signal Initial selectionsSelecting the On-Screen Menu Language INPUT1A INPUT1B INPUT2 PCAspect Controls Normal Zoom FullPanasonic Auto During Multi PIP OperationsAdjusting POS. /SIZE Clock PhaseRGB/PC in mode Eliminate the flickering and distortionMulti PIP Advanced PIP One screen Advanced PIP Press to exit from Options menuSub screen Main screen 1280x768@60Hz DVIPicture Adjustments Advanced Settings onAdvanced Settings OFF Standard Cinema DynamicAdvanced Settings Picture AdjustmentsEffect Adjustments Effect DetailsSound Adjustment MuteDigital Zoom Display the operation guidePosition Select the magnification required for the enlarged displayPresent Time Setup Press to set up DAY or Present Time of DAYButton Forward SET UP Timer Display the SET UP Timer Screen Press to selectPower on Time / Power OFF Time Mode selection Start settingScreensaver For preventing image retention Negative / Scroll selectionSetup of Screensaver Time Reduces screen image retentionScreensaver For preventing image retention Side BAR Adjust OFF Dark MID BrightPress to exit from Screensaver Reduces power consumption Customizing the Input labelsAddition sign Selected Input SET UP for Multi Display How to setup Multi DisplayPress to select Vertical Scale Press to select × 1, × 2, × 3, ×SET UP for Multi Display Display Number locations for each arrangement ExamplesSeam Hides Video Setting ID Remote Control FunctionID remote control button operation ID CancellationSET UP for Input Signals Component / RGB in Select3D Y/C Filter For Ntsc AV images SelectSET UP for Input Signals Color System / Panasonic AutoPulldown / Video NR Setting RGB sync signal SyncRefresh Rate FREQ. kHz / V-FREQ. HzOptions Adjustments Options1/3Options Adjustments Off Initial VOL Sets normal volume LevelEnable Normalization Weekly Command Timer Press to select a command number Press to select Time / CommandTime Set the time to execute a command program Press to set each itemShipping condition Troubleshooting Plasma Display panelVIDEO/COMPONENT/RGB/PC input signals Video inputPAL60 RGBCommand list of Weekly Command Timer Specifications TH-37PH10UK TH-42PH10UKSpecifications TH-50PH10UK TH-58PH10UKLimits and Exclusions Limited Warranty Statement Customer’s Record Panasonic Broadcast & Television Systems CompanyExecutive Office Panasonic Canada Inc