Sharp PNE521P, PNE601 manual Menu Items NOPTION, NENLARGE PC input

Page 12

Menu Items

nOPTION

DATE/TIME SETTING

Set the date and time. Press or to select the date

and time, and press or to change the numerical values.

Set the date in “Year/Month/Day” order.

Set the time on a 24-hour basis.

SCHEDULE (See page 15.)

You can set the time to switch the monitor on and off.

INPUT SELECT

Select the input mode to be used in PC/AV DVI-D input terminal, PC/AV HDMI input terminal and PC RGB/AV component input terminals.

AUDIO SELECT

Selects the terminal used to input audio signals in each input mode.

INPUT SIGNAL (PC D-SUB/PC RGB)

If a computer connected to the PC D-sub/PC RGB input terminal outputs any of the following resolutions, make a selection from the following options.

480 LINES

AUTO, 640x480 or 848x480

768 LINES

AUTO, 1024x768, 1280x768, or 1360x768

1050 LINES

1400x1050 or 1680x1050

ZOOM2 SPECIAL SETTING (See page 14.)

SCAN MODE (AV input)

Sets the scan mode used for AV mode input.

MODE1

Over-scan display

MODE2

Under-scan display

MODE3

Under-scan display when the input signal

 

is 1080i/p. Otherwise, over-scan display

*Even when MODE1 is selected, under-scan display is used when the input signal is 1080i/p and the screen size is Dot by Dot.

POWER MANAGEMENT

POWER MANAGEMENT determines whether or not to switch modes from no signal to the input signal standby mode.

COLOR SYSTEM (AV S-VIDEO/AV VIDEO)

Select the color system of the AV equipment which is connected to AV S-video and AV video input terminal. (AUTO / PAL / PAL-60 / SECAM / NTSC3.58 / NTSC4.43)

When AUTO is selected, the color system is automatically set according to the input signal.

AUDIO OUTPUT

Sets the volume of sound output from the audio output

terminals.

You can adjust the volume using VOLUME.

VARIABLE

FIXED

Fixes the sounds.

AUDIO INPUT LEVEL

Selects the maximum audio input level of the audio input terminal.

SELF ADJUST

On a PC D-SUB/PC RGB screen, specify whether to perform screen adjustment automatically or not. When ON is selected, the screen is automatically adjusted when its resolution is 800 x 600 or higher and the timing of input signals changes. “ADJUSTING” appears on the screen during the adjustment. Depending on the signal, adjustment may not be possible. In this case select OFF. (Perform manual adjustment of the screen.)

AUTO INPUT CHANGE

Specify whether to change inputs automatically. When ON is selected and no signal is present in the selected input mode, AUTO INPUT CHANGE automatically changes the selected mode to another mode where a video signal is present.

When video signals exist in multiple input modes, the switching priority is as follows:

PC D-SUB, PC HDMI and AV HDMI When the PN-ZB01 (optional) is attached:

PC DVI-D, PC HDMI, PC D-SUB, PC RGB, AV DVI-D, AV HDMI, AV COMPONENT, AV S-VIDEO and AV VIDEO (Input mode switching may take 15 seconds or more, depending on the connected equipment. Input signals may not be detected properly and a priority may change, depending on the connected equipment or video signals.)

nENLARGE (PC input)

ENLARGE H

Sets the number of screen splits (number of monitors) in the horizontal direction used for the enlargement. (See page 14.)

ENLARGE V

Sets the number of screen splits (number of monitors) in the vertical direction used for the enlargement. (See page 14.)

ENLARGE-POS H / ENLARGE-POS V

Specify the split screen to be displayed when the enlargement function is used. (See page 14.)

BEZEL H / BEZEL V

Sets the frame width of the display when the enlargement function is used.

H-POS

Adjust the horizontal position of the enlarged screen.

V-POS

Adjust the vertical position of the enlarged screen.

E12

Image 12
Contents PN-E601 PN-E521 Contents Part Names NFront viewNRear view Part Names NRemote control unit Signal transmitter Power buttonInput button See Basic Operation MuteMenu DisplayBasic Operation NSwitching the screen size Wide Zoom NormalDot by Dot Cut offMenu Items Displaying the menu screenNExample of operation NMenu screen displayList of menu items Menu ItemsMenu PN-ZB01 optional Not attached Attached 3D-Y/CSome items may not be displayed depending on the input mode LinesPIP/PbyP PbyP2 POSMenu item details NSCREENNPICTURE NSETUP 11 ENAUDIO Menu Items NOPTION NENLARGE PC input13 E NPIP/PbyPMenu Items NDual screen display NZOOM2 Special Setting Setting procedureMenu Items NEnlarge Enlarge menu, set Enlarge H/V and ENLARGE-POS H/V. SeePower 15 ENSCHEDULE DAY of the WeekAdjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment 17 E Communication procedure Controlling the Monitor with a PC RS-232CPC connection Communication conditions19 E NCommunication intervalNID numbers Example IDLK0002 002VOLM0030 VOLM0020 ←Setting of the Gamma user data 21 ERS-232C command table Power control/Input mode selectionHow to read the command table Command Command field See Direction23 E Controlling the Monitor with a PC RS-232C Picture menuAudio menu Controlling the Monitor with a PC RS-232C Setup menu 25 E Controlling the Monitor with a PC RS-232C Option menuImage Position Epos setting Horizontal orientation Vertical orientationInitialization/Functional Restriction Setting Function menu 27 EControlling the Monitor with a PC RS-232C PIP/PbyP menu Commands for setting of the Gamma user data Controlling the Monitor with a PC RS-232C OthersSettings to connect to a LAN Controlling the Monitor with a PC LAN29 E To set on the monitorThis monitor is factory preset as shown below IP Address Default Gateway 0.0Controlling the Monitor with a PC LAN To set from a PC 31 E Controlling with a PCControlling the Monitor with a PC LAN Basic operationSetup See Information about this monitor appearsMonitor’s menu Screen SeeUser Name / Password 33 EDNS Server Accept IP AddressInstallation Information NAME/LOCATION AuthenticationAccount Name / Password Monitor Name35 E Recipient E-MAIL AddressesCondition ConfirmationSnmp Setting Trap SettingTrap When Authentication Fails VersionTroubleshooting 37 EPN-E601E521 G EN09L2