Controlling the Monitor with a PC (LAN)
■ SNMP
You can configure settings related to SNMP.
SNMP SETTING
Set whether to enable or disable SNMP.
VERSION
Set the version of the SNMP to be supported.
COMMUNITY NAME 1 to 3
Set the name of the community required for the access.
User 1 to 3
Set the user name, password, authentication method and other options required for access.
TRAP SETTING
Set whether to enable or disable the trap function.
When this function is enabled, a trap will be sent when the monitor is turned on.
TRAP WHEN AUTHENTICATION FAILS
Set whether the trap function sends a notification when authentication fails.
TRAP ADDRESS & PORT NO.
Set the destination address and port number of the notification sent by the trap function.
Caution
•After you set SNMP, click [Restart the monitor immediately.] or turn off the monitor and then turn it on again with the main power switch. When the monitor restarts, wait about 30 seconds and then start the next operation.
TIPS
•Depending on the SNMP settings, a short delay may occur before the SNMP is usable. (About 2 minutes)
•Up to 16 alphanumeric letters and symbols can be used for the community name, user name and password.
■ SERVICE & SUPPORT (URL INFORMATION)
You can display a specific URL in the URL INFORMATION field on the INFORMATION screen when an error occurs in the monitor. (See page 32.)
URL INFORMATION
Enter the URL to display on the INFORMATION screen when an error occurs on the monitor.
Up to 64 alphanumeric characters or symbols can be used.
CONDITION
Specify the condition to display the URL.
CONFIRMATION
The home page of the specified URL is displayed.
You can check whether the URL you entered is correct.
TIPS
•It is also possible to specify the message text, such as the name of a contact or a telephone number, to be displayed instead of the linked URL.
E36