Initialization (Reset)/Functional Restriction Setting (FUNCTION)

You can return the settings to their factory-preset values and restrict operations.

1.After pressing SIZE for about 5 seconds, press , , , and in that order.

FUNCTION

1/1

 

 

 

 

ALL RESET

 

 

 

 

 

OFF

 

ADJUSTMENT LOCK

 

RS-232C

UNLOCKED

 

OSD DISPLAY

ON

 

LED

ON

 

TEMPERATURE ALERT

LED

 

STATUS ALERT

OFF

 

POWER BUTTON

MONITOR

 

CONTROLLER INPUT

 

 

 

 

END[MENU]

2. Select and set the items.

ALL RESET

Resets the settings to the factory default settings.

Press , select ALL RESET, and then press MENU .

After initialization, turn the main power switch off and then back on.

When the PN-ZB01 (optional) is attached, press , select the resetting method, and then press MENU .

ALL RESET1.....Resets all the settings to the factory

default settings.

ALL RESET2.....Returns all settings to the factory default

settings except for the following items: LAN SETUP, RS-232C/LAN SELECT, ID No. SET, BAUD RATE, NETWORK, MAIL, SERVICE & SUPPORT, and SNMP (See page 11, and pages 33 to 36.)

ADJUSTMENT LOCK

You can disable operations on the monitor and the remote control unit that use buttons.

OFF....Enables operation.

1.........Disables all operations other than turning power

on/off and FUNCTION.

2.........Only the FUNCTION operation is enabled.

Disables all operations other than FUNCTION (not even power on/off).

RS-232C

(RS-232C/LAN when the PN-ZB01 (optional) is attached)

Specifies whether to allow control via RS-232C or LAN (see pages 18 and 29).

OSD DISPLAY

Hides/shows menus.

The FUNCTION screen cannot be hidden.

LED

Specifies whether to light the power LED.

OFF cannot be selected when STANDBY MODE is LOW POWER.

TEMPERATURE ALERT

Selects the notification method for an abnormal

temperature.

 

OFF

Do not notify about an abnormal

 

temperature.

OSD & LED...

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately and the screen

 

displays a message: TEMPERATURE.

LED

When an abnormal temperature is

 

detected, the power LED flashes in red

 

and green alternately.

STATUS ALERT

Selects the notification method for a hardware error.

OFF

Do not notify about the error.

OSD & LED...

When a hardware error is detected, the

 

power LED flashes in red and the screen

 

displays a message: STATUS [xxxx].

LED

When a hardware error is detected, the

 

power LED flashes in red.

POWER BUTTON

Normally, leave this setting as MONITOR.

When using an optional part, if instruction appears, change the setting accordingly.

CONTROLLER INPUT

Normally, you do not need to change this setting. When using an optional part, if instruction appears, change the setting accordingly.

3. Press MENU to return to the normal screen.

TIPS

When both abnormal temperature and hardware error are detected, the hardware error notification overrides.

17 E

Image 17
Contents PN-E601 PN-E521 Contents NRear view Part NamesNFront view Input button See Part Names NRemote control unitSignal transmitter Power button Mute Basic OperationMenu DisplayWide Zoom Normal Basic Operation NSwitching the screen sizeDot by Dot Cut offDisplaying the menu screen Menu ItemsNExample of operation NMenu screen displayMenu Items List of menu itemsMenu PN-ZB01 optional Not attached Attached 3D-Y/CLines Some items may not be displayed depending on the input modePIP/PbyP PbyP2 POSNPICTURE Menu item detailsNSCREEN NAUDIO NSETUP11 E NENLARGE PC input Menu Items NOPTIONMenu Items NDual screen display 13 ENPIP/PbyP Setting procedure NZOOM2 Special SettingMenu Items NEnlarge Enlarge menu, set Enlarge H/V and ENLARGE-POS H/V. See15 E PowerNSCHEDULE DAY of the WeekNScreen display for adjustment Adjustments for PC screen displayNAutomatic adjustment 17 E Controlling the Monitor with a PC RS-232C Communication procedurePC connection Communication conditionsNID numbers 19 ENCommunication interval 002 Example IDLK0002VOLM0030 VOLM0020 ←21 E Setting of the Gamma user dataPower control/Input mode selection RS-232C command tableHow to read the command table Command Command field See DirectionAudio menu 23 EControlling the Monitor with a PC RS-232C Picture menu Controlling the Monitor with a PC RS-232C Setup menu Controlling the Monitor with a PC RS-232C Option menu 25 EHorizontal orientation Vertical orientation Image Position Epos settingControlling the Monitor with a PC RS-232C PIP/PbyP menu Initialization/Functional Restriction Setting Function menu27 E Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataControlling the Monitor with a PC LAN Settings to connect to a LAN29 E To set on the monitorControlling the Monitor with a PC LAN To set from a PC This monitor is factory preset as shown below IP AddressDefault Gateway 0.0 Controlling with a PC 31 EControlling the Monitor with a PC LAN Basic operationInformation about this monitor appears Setup SeeMonitor’s menu Screen See33 E User Name / PasswordDNS Server Accept IP AddressAuthentication Installation Information NAME/LOCATIONAccount Name / Password Monitor NameRecipient E-MAIL Addresses 35 ECondition ConfirmationTrap Setting Snmp SettingTrap When Authentication Fails Version37 E TroubleshootingPN-E601E521 G EN09L2