Sharp PN-V601 manual Menu Items NMULTI, NPIP/PbyP, NDual screen display

Page 12

Menu Items

nMULTI

ENLARGE (See page 13.)

Sets whether or not to use the enlarge function.

ADVANCED (ENLARGE)

ENLARGE H / ENLARGE V

.......... Sets the number of screen splits (number of

monitors) in the horizontal/vertical direction used for the enlargement.

ENLARGE-POS

.......... Specify the split screen to be displayed when the

enlargement function is used. H-POS / V-POS

.......... Adjust the horizontal/vertical position of the enlarged

screen.

BEZEL ADJUST

Sets whether or not to use the frame correction function.

ADVANCED (BEZEL ADJUST)

BEZEL ADJUST (TOP) / BEZEL ADJUST (BOTTOM) / BEZEL ADJUST (RIGHT) / BEZEL ADJUST (LEFT)

.......... Adjusts so that the top/bottom/left/right connecting

joints of grouped units will be displayed smoothly when a group of monitors are aligned in multiples to display a single image.

BEZEL H / BEZEL V

.......... Sets the frame width of the display.

nPIP/PbyP

PIP MODES

Sets the display method.

OFF

Displays one screen.

PIP

Displays a sub screen inside a main screen.

PbyP

Displays a main screen and a sub screen in a line.

PbyP2

Displays a main screen which measures 1024 pixels

 

in the longest direction and a sub screen in a line.

PIP SIZE

Sets the size of the sub screen in PIP mode.

PIP H-POS

Adjusts the horizontal position of the sub screen in PIP mode.

PIP V-POS

Adjusts the vertical position of the sub screen in PIP mode.

PIP BLEND

In PIP mode, use this menu item to display the sub screen transparently.

PIP SOURCE

Selects the input signal of the sub screen in PIP, PbyP, or PbyP2 mode.

SOUND CHANGE

Sets the sound which is output in PIP, PbyP, or PbyP2 mode. If the main screen is displayed as a full screen by the AUTO OFF function, the sound for the main screen is output even

when the sound for the sub screen is specified.

MAIN POS

Sets the position of the main screen in PbyP or PbyP2 mode.

PbyP2 POS

Sets the position of the sub screen in PbyP2 mode.

AUTO OFF

Sets the display method when no signals for the sub screen are input in PIP, PbyP, or PbyP2 mode.

MANUAL

Displays a main screen and a black sub screen.

AUTO

Displays the main screen as a full screen.

TIPS

When WHITE BALANCE is set to THRU, BLACK LEVEL,

CONTRAST, TINT, COLORS and GAMMA cannot be set.

If COLOR MODE is set to sRGB, the following items cannot be set.

WHITE BALANCE, PRESET, USER, COPY TO USER, and

GAMMA

When the COLOR MODE is set to VIVID, GAMMA can not be adjusted.

If GAMMA is set to USER, the following items cannot be set.

WHITE BALANCE, PRESET, USER, and COPY TO USER

STANDBY MODE cannot be set to LOW POWER when

SCHEDULE is effective or when OFF is selected for LED in

FUNCTION.

nDual screen display

You can display the screens of the PC input signal and AV input signal simultaneously.

Set this function with “PIP MODES” in the PIP/PbyP menu.

PIP

 

 

 

 

 

 

 

 

A sub screen is displayed

 

 

 

 

 

 

 

 

 

 

Main screen

 

 

 

 

inside a main screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sub

 

 

 

 

 

 

 

 

screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PbyP

 

 

 

 

 

 

 

 

A main screen and a sub

 

 

 

 

 

 

 

 

 

 

Main

 

 

 

Sub

 

screen are displayed in a

 

 

 

 

 

line.

 

 

screen

 

screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PbyP2

 

 

 

 

 

 

 

 

Displays a main screen

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which measures 1024

 

 

 

 

 

 

Sub

 

 

 

Main screen

 

 

pixels in the longest

 

 

 

screen

 

 

 

 

 

 

 

 

 

 

direction and a sub

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screen in a line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*The currently selected input signal is displayed on the main screen.

*You cannot simultaneously display the screens of signals of the same type, such as two types of PC input signals or two types of AV input signals.

*The dual screen display cannot be used with the combination of PC DVI-D and AV HDMI or of AV DVI-D and

PC HDMI.

TIPS

You might infringe on a copyright of the author which is protected by copyright law when you display the images of the computer screen and television/VCR simultaneously for profit-making or to show the image to the public.

The screen size for dual-screen display is the same as the screen size for single-screen display. The Dot by Dot screen is displayed in NORMAL size except when it is set as the PIP main screen.

When dual-screen display is selected, the SCREEN

MOTION function is disabled.

When dual-screen display is selected, the AUTO INPUT

CHANGE function is disabled.

When dual-screen display is selected, the screen cannot be enlarged.

When dual-screen display is selected, the INPUT SELECT options cannot be set.

E12

Image 12
Contents PN-V601 Contents Part Names NFront viewNRear view Page Basic Operation MuteMenu DisplayBasic Operation NSwitching the screen size Wide Zoom NormalDot by Dot Cut offRemote Control Mode Press or , select the mode, then perform settingsThis Monitor only Specified MonitorMenu Items Displaying the menu screenNExample of operation NMenu screen displayMenu item details NSCREENMenu Items NPICTURE NSETUP Menu Items NAUDIO11 E NOPTIONMenu Items Menu Items NMULTI NPIP/PbyPNDual screen display Menu Items NZOOM2 Special Setting Setting procedureSet using the Multi menu 13 EPower Menu Items NSCHEDULEDAY of the Week InputAdjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment 15 EALL Reset Temperature AlertAdjustment Lock LEDCommunication procedure Controlling the Monitor with a PC RS-232C17 E PC connectionNCommunication interval NID numbers19 E Setting of the Gamma user data RS-232C command table Power control/Input mode selection21 E Controlling the Monitor with a PC RS-232CControlling the Monitor with a PC RS-232C Picture menu Audio menuControlling the Monitor with a PC RS-232C Setup menu 23 EControlling the Monitor with a PC RS-232C Option menu Image Position Epos setting 25 EControlling the Monitor with a PC RS-232C Multi menu Horizontal orientation Vertical orientationInitialization/Functional Restriction Setting Function menu Controlling the Monitor with a PC RS-232C PIP/PbyP menuCommands for setting of the Gamma user data 27 EControlling the Monitor with a PC RS-232C Others Settings to connect to a LAN Controlling the Monitor with a PC LANTo set on the monitor This monitor is factory preset as shown below IP Address Default Gateway 0.029 E To set from a PCSee pages 31 to 35 for details on each setting Controlling with a PCBasic operation If the Dhcp Client is set to OFF, specify an IP address31 E User Name / Password DNS ServerAccept IP Address IP Address 1 to33 E Attach the log file to a TEMPERATURE/HARDWARE error e-mail Recipient E-MAIL AddressesCondition Confirmation35 E Troubleshooting Specifications NPN-V601 Product SpecificationsNPN-ZR01 optional Product Specifications 37 ESpecifications NDimensional Drawings NPower managementDmpm Digital Monitor Power Management NDDC plug and playSpecifications NCompatible signal timing PC 39 ESpecifications NCompatible signal timing AV 41 E PN-V601 G EN10G1
Related manuals
Manual 42 pages 42.72 Kb

PN-V601 specifications

The Sharp PN-V601 is a cutting-edge display solution that meets the demands of various professional environments. This 60-inch LCD monitor is designed for commercial use, offering a blend of remarkable performance, flexibility, and reliability.

One of the standout features of the PN-V601 is its superb display quality. With a Full HD resolution of 1920 x 1080 pixels, this monitor delivers vibrant colors and sharp images that are essential for presentations, digital signage, and collaborative workspaces. The display utilizes advanced LCD technology, which provides wide viewing angles up to 178 degrees both horizontally and vertically. This ensures that the content remains visible and engaging from various positions in a room.

The PN-V601 is engineered with a sleek and slim design, making it an aesthetically pleasing addition to any environment. Its thin bezels allow for seamless video wall configurations, enabling the creation of large-scale visual displays. When arranged in a multi-screen setup, the PN-V601 ensures minimal gaps between the screens, enhancing the overall viewing experience.

In terms of connectivity, the Sharp PN-V601 is equipped with a wide range of input options, including HDMI, DisplayPort, and DVI-D. This versatility allows for easy integration with external devices such as computers, media players, and video conferencing systems, ensuring that users can present or share information without hassle.

One of the key technologies integrated into the PN-V601 is the advanced image processing capabilities, which enhance image quality through features like fine-tuning of brightness and color correction. This technology ensures that every detail is vividly displayed, making it ideal for showcasing high-definition content.

Moreover, the PN-V601 has been designed for continuous operation, making it suitable for environments that require displays to run around the clock, such as retail displays and control rooms. The robust build quality ensures longevity and durability, reducing maintenance costs over time.

Another notable characteristic is its energy efficiency. The PN-V601 adheres to modern sustainability standards, minimizing power consumption while delivering outstanding performance. This makes it an environmentally friendly choice, aligning with corporate social responsibility initiatives.

Overall, the Sharp PN-V601 offers a powerful combination of elegance, functionality, and advanced technology, making it an exceptional choice for businesses looking to enhance their visual communication capabilities. Whether used for digital signage, presentations, or collaborative work, this display is engineered to impress.