Item | Measuring | Test point | Ad justment part | Description | |||
instrument | |||||||
|
|
|
|
|
| ||
|
|
|
|
|
|
| |
Ad justment | Remote |
| 3. | BRIGHT | 1.Receive any broadcast. | ||
of | control unit |
|
|
| 2.Enter the SERVICE MENU. | ||
|
|
|
| ||||
SUB BRIGHT |
|
|
|
| 3.Select 2. V/C from SERVICE MENU. | ||
|
|
|
|
| 4.Select 3. BRIGHT with the MENU ▼/▲key. | ||
|
|
|
|
| 5.Set the initial setting value with the MENU | ||
|
|
|
|
| 6.If the brightness is not the best with the initial set value, make | ||
|
|
|
|
| fine adjustment until you get the best brightness. | ||
|
|
|
|
|
|
| |
Ad justment | Remote |
| 4. | CONT . | 1.Receive any broadcast. | ||
of | control unit |
|
|
| 2.Enter the SERVICE MENU. | ||
|
|
|
| ||||
SUB CONT. |
|
|
|
| 3.Select 2. V/C from SERVICE MENU. | ||
|
|
|
|
| 4.Select 4. CONT. with the MENU ▼/▲key. | ||
|
|
|
|
| 5.Set the initial setting value with the MENU | ||
|
|
|
|
| 6.If the contrast is not the best with the initial set value, make fine | ||
|
|
|
|
| adjustment until you get the best contrast. | ||
|
|
|
|
|
|
| |
Ad justment | Remote |
| 5. | COLOUR | [Method of adjustment without measuring instrument] | ||
of | control unit |
|
|
|
|
| |
|
|
|
|
|
| ||
SUB |
|
|
|
|
|
| |
COLOUR Ⅰ |
|
| PAL COLOUR | 1.Receive a PAL broadcast. | |||
|
|
|
|
| 2.Enter the SERVICE MENU. | ||
|
|
|
|
| 3.Select 2. V/C from the SERVICE MENU. | ||
|
|
|
|
| 4.Select 5. COLOUR with the MENU ▼/▲ key. | ||
|
|
|
|
| 5.Set the initial setting value for PAL COLOUR with the MENU | ||
|
|
|
|
| |||
|
|
|
|
| 6.If the colour is not the best with the initial set value, make fine | ||
|
|
|
|
| adjustment until you get the best colour. |
SECAM COLOUR
1.Receive a SECAM broadcast.
2.Make fine adjustment of SECAM COLOUR as previously.
NTSC 3.58 COLOUR
1.Receive a NTSC 3.58MHz broadcast.
2.Make similar fine adjustment of NTSC 3.58 COLOUR as previously.
NTSC 4.43 COLOUR
When NTSC 3.58 adjustment completed, NTSC 4.43 will be automatically set at the respective values.
No. 52026 | 23 |