JVC HV-29LPZ/EE, HV-29LPZ/HK, HV-29LPZ/-A Adjustment, Checking Item, Rgb Blk, Def Pwb, Att On/Off

Page 20

HV- 29LPZ

ADJUSTMENT

CHECKING ITEM

Item

Measuring

Test point

Adjustment part

instrument

 

 

Description

 

Check of B1

 

Signal

TP-91(B1)

1. RGB BLK

1.

Receive any broadcast.

 

 

 

 

Power Supply

 

Generator

TP-E(#)

 

 

 

2.

Press the ZOOM key and select the FULL mode.

 

 

 

 

 

 

 

[X connector

 

 

 

3.

Select 2. V/C from the SERVICE MENU.

 

 

 

 

 

 

DC voltmeter

on POWER

 

 

 

4.

Select 1. RGB BLK with function UP / DOWN key.

 

 

 

 

 

 

 

DEF PWB]

 

 

 

5.

Press the function (

) key to find the cut off screen (Black

 

 

 

 

 

 

Remote

 

 

 

 

 

screen).

 

 

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

6.

Connect a DC voltmeter to TP-91(B1) and TP-E(#).

 

 

 

 

 

 

 

 

 

 

 

7.

Make sure that the voltage is DC139.9 ±2.0V.

 

 

 

 

 

 

 

 

 

 

 

8.

Press the function (

) key to return to service menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check of High

 

Signal

CRT anode

1. RGB BLK

1.

Receive any broadcast.

 

 

 

 

Voltage

 

Generator

 

 

 

 

2.

Press the ZOOM key and select the FULL mode.

 

 

 

 

 

 

 

Chassis GND

 

 

 

3.

Select 2. V/C from the SERVICE MENU.

 

 

 

 

 

 

 

 

 

 

4.

Select 1. RGB BLK with function UP / DOWN key.

 

 

 

 

 

 

DC volunteer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Press the function (

) key to find the cut off screen (Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screen).

 

 

 

 

 

 

 

 

 

 

 

Remote

 

 

 

 

6.

Connect a DC voltmeter to CRT ANODE and chassis GND.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+1kV

 

 

 

 

 

 

Control unit

 

 

 

 

7.

Make sure that the voltage is DC 31.5kV -1.5kV .

 

 

 

 

 

 

 

 

 

 

 

8.

Press the function (

) key to return to service menu.

 

 

 

 

 

 

 

 

 

 

 

*

Remove the probe before removing the earth clip.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check of VCO

 

Remote

 

1. VCO

" Under normal conditions, no adjustment is required.

 

 

 

 

 

 

control unit

 

2. ATT ON/OFF

"

Confirmation adjustment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Select 1.IF from the SERVICE MENU.

 

 

 

 

 

 

 

 

 

 

 

2.

Then select 1.VCO from the IF SERVICE MENU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Receive any broadcast.

 

 

 

 

 

 

 

 

 

IF SERVICE MENU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Check the MAIN arrow (

 

 

) position between the ABOVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. VCO

 

 

 

 

 

REF. and BELOW REF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. ATT ON/OFF

 

 

 

 

5.

Press the MENU (OK) key and receive any broadcast with PIP

 

 

 

 

 

 

 

 

 

 

 

 

Button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.

Check the SUB arrow (

 

) position between the ABOVE REF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2 : SELECT

DISP : EXIT

 

 

 

 

and BELOW REF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

The arrow (

 

) position means AFC voltage level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

2. ATT ON/OFF : Generally Electric Field : OFF

 

 

 

 

 

 

 

 

 

 

 

*

 

 

: Strong Electric Field : ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change the MAIN and SUB by MENU/OK key .

 

 

 

 

 

 

 

 

 

 

 

VCO(CW) ****MHz

MAIN SUB

TOO HIGH

ABOVE REF

JUST REF

BELOW REF

TOO LOW

DISP : EXIT

20

No. 52012

Image 20
Contents Contents HV-29LPZ HV-29LPZ HV-29LPZ HV-29LPZSpecifications Safety Precautions Features Main Difference ListSystem Block Diagram Micom PWBMain PWB Sync SEP PWBFunctions Front Terminal & ControlRemote Control Unit SUB-PICTURESpecific Service Instructions Disassembly ProcedureControl Base Micom Power & DEF PWB Claw Chassis HV- 29LPZDome Speaker BOXRemoving the CRT Silicon grease product No. KS 650NCRT Change Table Approx Cloth CRT Cabinet Change TableSystem Constant SET Setting Values of System Constant SET Table Service Menu Setting Items TableModel No Setting item Setting item Setting valueUser Setting Values Table Picture SettingPicture Features SoundService Adjustments Before Starting Service AdjustmentAdjustment Items Measuring Instrument and FixturesAdjustment Locations Fron TTOP FrontBasic Operation Service Menu Tool of Service Menu OperationService Menu Items Zoom Aspect FreqBasic Operation of Service Menu VSM PresetWB Preset Shipping OFF Service MenuService Menu Screen Service MenuAUDIO, 6. STATUS, 9. Shippingoff & 0. BUS Free Method of SettingRelease of Service Menu Adjustment Checking ItemRGB BLK DEF PWBAdjustment of Focus & Screen Adjustment SignalFocus Screen VRVSM Preset Setting Standard Soft Setting Values of VSM PresetBright Sharp Colour Tint BrightVIDEO/CHROMA Circuit Adjustment Method of adjustment without measuring instrument PAL/SECAM/NTSC Colour ⅠPAL/SECAM/NTSC Colour Ⅱ CRT SUB Tint SUB Tint Ⅱ CRTDEF. Circuit Adjustment Regular Zoom100Hz 60Hz p Fixed ValueAdjustment ShiftSize Aspect Zoom Screen Regular PositionMode ADJ. Item Regular CenterAspect FixedTrapez COR-PINCorner COR-UP13.V.LIN LIN12.V-S.CR Quasi Audio Circuit AdjustmentAUDIODo not adjust Setting item Variable range Fixed value PURITY, Convergence Adjustment Purity AdjustmentMagnets Purity MagnetStatic Convergence Adjustment Front ViewReplacement of Chip Component Replacement StepsSoldering Iron # Resistors, capacitors, etcHV- 29LPZ