Daewoo CP005P-010G1 specifications Important Service Notes

Page 38

Important Service Notes

1. X-ray Radiation Rrecaution

1) Excessive high voltage can produce potentially hazardous X-RAY RADIA- TION. To avoid such hazards, the high voltage must not be above the spec- ified limit. The nominal value of the high voltage of this receiver is 25.5kv(20”/21”) & 23.5kv(14”)at zero beam current (minimum brightness) under a 120V/220V AC power source. The high voltage must not, under any circumstances, exceed 28kv(20”/21”) & 26kv(14”). Each time a receiver requires servicing, the high voltage should be checked following the HIGH VOLTAGE CHECK procedure on page 10 of this manual. It is recom- mended as a parts of the service record. It is important to use an accurate and reliable high voltage meter.

2)This receiver is equipped with X-RADIATION PROTECTION circuit which prevents the receiver from producing an excessively high voltage even if the B+voltage increases abnormally. Each time the receiver is serviced, X- RADIATION PROTECTION circuit must be checked to determine that the circuit is properly functioning, following the X-RADIATION PROTECTION CIRCUIT CHECK procedure on page 6 of this manual.

3)The only source of X-RAY RADIATION in this TV receiver is the picture tube. For continued X-RAY RADIATION protection, the replacement tube must be exactly the same type tube as specified in the parts list.

4)Some parts in this receiver have special safety-related characteristics for X- RAY RADIATION protection. For continued safety, parts replacement should be undertaken only after referring to the PRODUCT SAFETY NOTICE below.

2. Safety Precaution

WARNING: Service should not be attempted by anyone unfamiliar with the necessary precaution on this receiver. The following are the necessary precau- tion to be observed before servicing.

1)Since the chassis of this receiver has hazardous potential to ground when- ever the receiver is plugged in (floating chassis), an isolation transformer must be used during servicing to avoid shock hazard.

2)Always discharge the picture tube anode to the CRT conductive coating the picture tube. The picture tube is highly evacuated and if broken, glass frag- ments will be violently expelled. Use shatterproof goggles and keep picture tube away from the body while handling.

3)When placing chassis in the cabinet, always be certain that all the protective

devices are put back in place, such as; nonmetallic control knobs, insulat- ing covers, shields, isolation resistor-capacitor network, etc.

4)Before returning the set to the customer, always perform an AC leakage cur- rent check on the exposed metallic parts of the cabinet, such as antennas, terminals, screw-heads, metal overlays, control shafts etc. to be sure the set is safe to operate without danger of electrical shock. Plug the AC line cord directly into a 120V AC outlet (do not use a line isolation transformer during this check). Use an AC voltmeter having 5000 ohms per volt or more sensi- tivi-ty in the following manner.

Connect at 1500 ohm 10 watt resistor, paralleled by a 0.15 mfd. AC type capacitor, between a known good earth ground (water pipe, conduit etc.) and the exposed metallic parts, one at a time. Measure the AC voltage across the combination of 1500 ohm resistor and 0.15 mfd capacitor. Volt- age measured must not exceed 0.3 volts RMS. This corresponds to 0.2 mill- liamp. AC. Any value exceeding the limit constitutes a potential shock hazard and must be corrected immediately.

AC VOLT METER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.15uF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

 

 

OHM

 

 

Place this probe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Good earth ground

 

 

 

 

 

 

 

 

 

on each exposed

 

 

 

 

 

 

 

 

 

metallic part.

such as d water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pipe, conduit, etc.

 

10WATT

 

 

 

3. Product Safety Notice

Many electrical and mechanical parts in this chassis have special safety-related characteristics. These characteristics are often passed unnoticed by a visual inspection and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identi- fied in this manual and its supplements; electrical components having such fea- tures are identified by shading on the schematic diagram and the parts list.

Before replacing any of these components, read the parts list in this manual carefully. The use of substitute replacement parts which do not have the same safety characteristics as specified in the parts list may create X-ray radiation or other hazards.

4. Service Notes

1)When replacing parts or circuit boards, clamp or bend the lead wires to termi- nals before soldering.

2)When replacing a high wattage resistor (metal oxide film resistor) in the cir- cuit board, keep the resistor min 1/2 inch away form circuit board.

3)Keep wires away from high voltage or high temperature components.

DAEWOO ELECTRONICS CO., LTD.

C.P.OBOX8003 SEOUL, KOREA

Tel : 82-2-360-7798

Fax : 82-2-360-7877

E-mail : G7F00E@dwe.web.co.kr

Printed in Apr. 2000

Image 38
Contents Service Guide #$%&%*+ Product Safety Servicing Guidelines for Audio Video Products Safety Checks Subject Implosion CP-005 Chassis Enter Service Mode Screen Geometry Vertical Center Page ST92195B Device Summary3 I/O Ports Power Saving Modes1 ST9+ Core TV PeripheralsPWM Output Voltage Synthesis Tuning ControlStandard Timer Stim Serial Peripheral Interface SPIST92195 Block Diagram PIN Description PIN Description Cont’d ST92195 Required External components ST92195 I/O Port Alternate Function Summary PIN Description Cont’d P070, P250, P374, P470, P5101 I/O Port Alternate Functions Example 1 ADC trigger digital input How to Read this Table2 I/O Port Styles Example 2 PWM 0 outputDPM STV223XD/223X/224X STV223XD/3X/4X BCL/SAF PIN Connections STV223XD TQFP64 Block Diagram STV2238D TQFP64 No Power No Picture No Sound No Color No ON-SCREEN Display %!-$1 Page +*+ $*#+ #*#+ $#%# Mechanical Exploded View Important Service Notes Alignment Instructions Geometry Vertical Center Electrical Parts List HRFT470JCA Chip Video