Mitsumi electronic DX-TL4716U instruction manual Countermeasure Cancelling, Hdd

Page 40

Warnings and CALL OUT output

Warnings and their appropriate countermeasures

#1 Options in the CALL OUT output column:

Selectable: Selects to output CALL OUT signal or not on the menu screen.

Fixed: Outputs CALL OUT signal from the CALL OUT terminal regardless of the menu setting.

None: Does not output CALL OUT signal, but displays a warning on the screen.

The warning display appears when the HELP button is pressed during “ALERT” is displayed on the screen. The contents

of last 16 warnings are stored and can be displayed. The contents older than them are cleared and output of CALL OUT is cancelled. CALL OUT signal output can be stopped by pressing the E button or clicking “Clear Warning” while displaying the warning display.

Warning Display

Countermeasure

Cancelling

Log number

 

CALL OUT

 

output

 

 

the warning

 

#1

 

 

 

 

The remaining capacity of Normal Area

• Copy data as necessary.

Click "Clear

LOG1200

 

Selectable

in Main device has become less than **%.#2

 

Warning" or

 

 

 

The remaining capacity of Alarm Area

 

press the E

LOG1201

 

 

in Main device has become less than **%.#2

 

button.

 

 

 

The remaining capacity of LPA Area

 

 

LOG1202

 

 

in Main device has become less than **%.#2

 

 

 

 

 

 

 

 

 

 

 

The remaining capacity of Copy 2 disk

 

 

LOG7200

 

 

has become less than **%.#2

 

 

 

 

 

The remaining capacity of Normal Area

• When the warning is cancelled,

Click "Clear

LOG1100#3

 

Selectable

in Main device has become 0%.

the unit starts overwriting the

Warning" or

LOG4100#4

 

None

The remaining capacity of Alarm Area

oldest data remaining in the

press the E

LOG1101#3

 

Selectable

in Main device has become 0%.

HDD.

button.

LOG4101#4

 

None

The remaining capacity of LPA Area

• Copy data as necessary.

 

LOG1102

 

Selectable

in Main device has become 0%.

 

 

 

 

 

The remaining capacity of disc in Copy 1

• Replace media if necessary.

Click "Clear

LOG3100

 

None

drive has become 0%.

 

Warning" or

 

 

 

The remaining capacity of disc in Copy 2

 

press the E

LOG7100

 

Selectable

drive has become 0%.

 

button.

 

 

 

Copy data size error.

• Set the copy/restore range again.

Click "Clear

LOG3701#5

 

None

 

• Replace with new media.

Warning" or

LOG7701#6

 

 

Check the range of copy data or the disk space

 

press the E

LOG4701#4

 

 

of copy media.

 

button.

 

 

 

Copy media error.

• Check that media is in the

Click "Clear

LOG3702#5

 

None

 

recording device. (If not, insert

Warning" or

LOG7702#6

 

 

Cannot copy the data.

the media.)

press the E

LOG4702#4

 

 

Check the copy device.

• Check whether that the write-protect

button.

 

 

 

 

of the media is enabled. If so,

 

 

 

 

 

cancel the protection.

 

 

 

 

 

• After turning off the power of the

 

 

 

 

 

peripheral recording device and

 

 

 

 

 

the unit, reboot in order of

 

 

 

 

 

peripheral recording device and

 

 

 

 

 

the unit.

 

 

 

 

 

• After turning off the power of the

 

 

 

 

 

peripheral recording device and

 

 

 

 

 

the unit, check a cable.

 

 

 

 

 

• Replace the disc.

 

 

 

 

No disk.

• Insert the disc.

Click "Clear

LOG3703#5

 

None

 

• Replace the disc.

Warning" or

LOG7703#6

 

 

The drive has no disk or wrong type of disk.

 

press the E

LOG4703#4

 

 

Put a proper disk into the drive.

 

button.

 

 

 

The remaining capacity of disc in Copy 1

• Replace the disc.

Click "Clear

LOG3704#5

 

None

drive has become 0%.

 

Warning" or

 

 

 

Put a new disk into the drive.

 

press the E

 

 

 

The remaining capacity of disc in Copy 2

 

button.

LOG7704#6

 

 

drive has become 0%.

 

 

 

 

 

Put a new disk into the drive.

 

 

 

 

 

#2 : The value depends on the setting.

#3 : Log number for recording

#4 : Log number for restore

#5 : Log number for copy 1

#6 : Log number for copy 2

#7 : (The following numbers are entered in ) 01 : CH 1 02 : CH 2 03 : CH 3 04 : CH 4

05 : CH 5 06 : CH 6 07 : CH 7 08 : CH 8

09 : CH 9 10 : CH 10 11 : CH 11 12 : CH 12

13 : CH 13 14 : CH 14 15 : CH 15 16 : CH 16

#8 : 13

,14

: Recording

23

,24

: Playback

33

,34

: Copy 1

43

,44

: Restore

73

,74

: Copy 2

 

 

 

(The following numbers are entered in

)

00

: A (Internal) 01 : B (Internal)

 

 

10 to 25 : USB (External)

 

 

 

36

Image 40
Contents DX-TL4716U Page Avertissement Important safeguards Damage requiring Service Replacement PartsSafety Check ServicingUnplug the Power Cord During a Long Absence Recordable time and product warranty DisclaimerInstallation Location and Handling Contents Page Software License Agreement How to set the menus Setting the menusSetting the menu using a mouse Setting the menu using the front panel buttonsClosing a menu screen Displaying a menu screenSelecting an item Setting parameters Using the front buttons of the unitUsing a mouse Inputting numbersSymbols in the menus Motion Search Main Normal 116 000Setting the time and date Time/Date SettingBasic multiplexer functions Using the basic multiplexer functionsMultiplexer buttons PTZ control using the front panel buttons PTZ control using the menuControlling the camera Recording the picture manually Basic manual recordingBasic playback Playing back the recorded dataTo change the playback device Basic search Searching the desired pictureSearch by Time and Date Search by Alarm List Searching the desired pictureCopying the recorded data Copy Data to Copy 1 Drive/Set Copy 1 DriveCopying the recorded data Copy Data to Copy 2 Drive/Set Copy 2 DriveCopying the data of this unit to a video cassette Playback software System requirementsStarting up the application software Operational panelFile menu Search menuOperation menu Bookmark menuLogin Communications by Web BrowserCommunications by Web Browser Personal computer product requirementsMain Menu Communications by Web Browser Live MonitoringPlayback Time SearchConfiguration Menu Alarm List SearchImage Search User Registration Mail Setup Recorder Title & Camera TitlesCommunications by Web Browser Access Mode Setup Clock SetupLogout Change Login User Troubleshooting InstallationTroubleshooting Countermeasure Cancelling HDDLOG13 Page

DX-TL4716U specifications

The Mitsumi electronic DX-TL4716U is a versatile and highly regarded electronic component that is primarily utilized in a range of industrial applications, particularly in automation and control systems. This device stands out due to its advanced capabilities and robust design, making it an essential component for modern electronic systems.

One of the main features of the DX-TL4716U is its highly efficient power management system. It is designed to operate seamlessly with various power supply configurations, ensuring that it can accommodate different operational environments. This adaptability makes it suitable for use in both consumer electronic products and high-demand industrial machinery.

The DX-TL4716U also supports multiple communication protocols, including I2C, SPI, and UART. This versatility allows the component to interface with a plethora of microcontrollers and other devices, optimizing integration into larger systems. The ease of communication it provides is essential for real-time data transfer and control, which is a significant requirement in fields such as robotics and telemetry.

Moreover, this component is equipped with features that enhance its reliability and efficiency. It comes with built-in protection mechanisms against over-voltage, over-current, and thermal overload. Such attributes ensure longevity and stability, critical for applications where downtime can result in significant losses.

The technology behind the DX-TL4716U incorporates advanced semiconductor materials, allowing for lower power consumption while maintaining high performance. This focus on efficiency is imperative in modern electronics, where energy conservation has become a priority. The device operates at a wide range of temperatures, making it suitable for applications in harsh environments.

In terms of physical characteristics, the DX-TL4716U is compact, enhancing its integration into various electronic layouts without requiring excessive space. This design consideration allows engineers to maximize the functionality of their systems without compromising on space.

In conclusion, the Mitsumi electronic DX-TL4716U exemplifies cutting-edge technology in the realm of electronic components. Its remarkable features, including versatile communication options, efficient power management, and robust protective mechanisms, position it as a key player in the fields of automation and control. As industries continue to evolve towards greater efficiency and reliability, the DX-TL4716U is well-equipped to meet these demands.