Adjusting or Changing Vibratory V-Belt
1.To adjust the
2.IMPORTANT! always adjust the vibratory
Adjusting or Changing Hydrostatic Pump Drive Belt
1.To change or adjust the clogged drive belt (Figure 34) for the hydrostatic pump, loosen the four mounting bolts on the hydrostaticpump.Movethepumpunittowardstherearofthe roller and adjust the clogged belt for approximately 1/2 inch (1.27 cm) deflection when the belt is pressed midway between the two pulleys. When the correct amount of belt deflection has been achieved, retighten hydrostatic pump mounting screws.
V304 — MAINTENANCE
Adjusting Control Rods
Travel Control Rod
1.To adjust the travel control rod (controls forward, reverse and neutral) it will be necessary to start the engine and run it a low speed.
2.On the travel control rod, loosen the counter nut on the rod end . Remove retaining screw as shown in Figure 35, then rotate the rod end to acquire desired length. Adjust travel rod so that its static position (no force applied on drive control) falls into the neutral position.The roller should not move once adjustment is complete. Retighten all hardware.
Figure 34. Hydrostatic Pump Drive Belt
NOTE
Use caution when adjusting control rods, since engine is running.
Figure 35.Travel and Vibratory V-Belts
Vibratory Control Rod
1.To adjust the vibratory control rod (controls vibration), loosen the counter nut (Figure 3) on the rod end of the vibratory control rod. Remove the retaining screw on the rod end and rotate the rod to achieve the desired rod length.
2.Continue adjusting, until clutch operation is adequate. The
PAGE 28