SPECTRA/ESPRIT CONTROL CONNECTIONS

If you connected a Spectra or Esprit camera positioning system directly to a video input port on the VMX300(-E) workstation (-1 or -4 models only), you must also connect a data cable to the VMX300(-E) workstation to provide direct camera control from the VMX300(-E).

1.Use one of the COM ports on the VMX300(-E) workstation for the control connection. Using an RS-422 COM port requires a wall block between the VMX300(-E) and the camera. If you use an RS-232 COM port, you will need an RS-232 to RS-422 converter (user-supplied) and power supply.

Use twisted pair wire to connect the Spectra or Esprit receivers to the COM port or the converter. You can daisy-chain (connect a series of cameras) from the Rx+ and Rx- connections on the first Spectra or Esprit to additional units.

NOTE: The Spectra IIID protocol provides a feedback option. “Feedback” refers to positioning data that is sent from the camera to the VMX300(-E). This positioning data rotates the camera icon viewed on the map in the VMX300(-E) client, based on the actual physical position of the camera. To receive feedback from the Spectra III, you must also connect Rx+ and Rx- on the wall block to Tx+ and Tx- on the Spectra III.

VMX300(-E)

VMX300(-E) COM 3 & 4

WALL BLOCK

RS-422 PIN ASSIGNMENTS

PIN ASSIGNMENTS

PIN 2

= Rx+

PIN 1

= Tx+

PIN 3

= Tx-

PIN 2

= Tx-

PIN 7

= Tx+

PIN 7

= Rx-

PIN 8

= Rx-

PIN 8

= Rx+

4

3

2

1

WALL

5BLOCK

6

7

8

RS-422

TO RECEIVERS

SPECTRA

ESPRIT

Figure 30. Spectra/Esprit Control Connections

2.After installing system hardware, complete the following configuration steps (refer to the VMX300(-E) Server Configuration Manual for detailed instructions):

a.Change the settings for the VMX300(-E) COM port to match the communication settings on the camera (baud rate, parity, etc.). Refer to the Appendix on page 42 for instructions.

b.Add the Pelco PTZ camera driver to the VMX300(E-) server configuration.

c.Add the PTZ device (the Spectra or Esprit camera) to the VMX300(E-) server configuration, using the following device properties:

(1)Communications tab, Connection Type: Select Direct Serial.

(2)Communications tab, Camera Address: Select the address that correspond to the DIP switch settings selected on the camera.

(3)Camera Model tab: Select the appropriate model and protocol; D protocol is recommended.

32

C1552M-C (7/07)

Image 36
Contents Addendum Rear ViewHow to Connect a Single Monitor to a VMX300-E Workstation VMX300-E Monitor OutputsVMX300-E Analog Video Inputs Model WorkstationsISO9001 Installation Manual Page Contents List of Illustrations List of TablesImportant Safety Instructions Regulatory Notices Video Quality CautionDescription Models VMX300 ModelsVMX300-E Models VMX300-E-CL-0 ClientVMX300E-B Backup Server Compatible ProductsDocumentation Resources Matrix Switchers Typical ApplicationsPelco Ascii Switchers Coaxitron and Fixed Camera Transmission DX8000 and DX9000 Series Dvrs Looping Camera OutputsConnecting a DVR Method Pelconet Transmission Systems NetworkNetworkip Example 3 of a PelcoNet Configuration NVR300 Network Video Recorder Sample VMX300-E System with the NVR300Installation Parts ListUSER-SUPPLIED Parts Rack Mount Installation MountingFront View Rear View VMX300-E Connections VMX300-E Connections to the NetworkVMX300-E Keyboard and Mouse Right VGA Monitor Video Input External Devices Direct Serial ConnectionInternet Protocol KBD300A Keyboard KBD300A Direct Serial ConnectionNetwork Keyboard SPECTRA/ESPRIT Control Connections Communications tab, Connection Type Select Direct SerialCM6700 Switcher Connect Ground on ONE END onlyCM6800 Switcher CM6800 Port ProgrammingAlternate CM6800 Connection CM9700 Matrix Switching Systems Alternate CM9700 Connection CM9760-ALM Alarm Interface Unit CM9760-REL Relay Interface Unit RDA RDB RS-422 Reversed CableSerial Output Device IP-BASED DevicesPower Cables Changing the Port Settings of a VMX300-E COM Port AppendixSpecifications ELECTRICAL/ VideoPage Product Warranty and Return Information ISO9001