Pelco VMX300 installation manual CM9760-ALM Alarm Interface Unit

Page 42

CM9760-ALM ALARM INTERFACE UNIT

To connect a CM9760-ALM alarm interface unit to the VMX300(-E), complete the following steps (refer to the CM9760-ALM Installation/Operation manual for detailed instructions):

1.Set DIP switch SW1 on the CM9760-ALM to use RS-232 communication on port 0.

2.Connect the alarm unit to the VMX300(-E) as described below for the appropriate communication mode:

Direct serial: Connect an RS-232 to RS-422 adapter to COM 1 or COM 2 on the VMX300(-E) workstation, and then wire the adapter to a wall block (user-supplied), as shown in Figure 36. Using an RS-422 reversed data cable, connect the wall block to the IN port on the CM9760-ALM.

VMX300(-E)

RS-232

45

36

WALL BLOCK

 

 

2

7

 

 

TD(A)

8

 

 

1

 

 

TD(B)

 

 

 

RD(A)

 

RS-232 TO

 

RD(B)

 

+12VDC

TD(A) TD(B) RD(A) RD(B) GND

RS-422 REVERSED CABLE

RS-422

 

 

 

ADAPTER

 

 

 

CM9760-ALM

Figure 36. CM9760-ALM Direct Serial Connection

Internet Protocol: Connect the RS-232 connector on the alarm unit to a serial port on a networked device, such as a PelcoNet encoder (refer to Figure 26 on page 28 for a sample illustration).

3.(Optional: daisy-chaining) If you are connecting multiple alarm units in a daisy-chain series, use the data cables provided with the alarm units to connect the first unit’s RJ-45 OUT port to the next unit’s RJ-45 IN port. You must configure each unit with a unique device address (refer to the VMX300(-E) Server Configuration Manual for instructions).

4.After installing system hardware, complete the following configuration steps:

a.Add the ALM driver and the alarm interface unit to the VMX300(-E) server configuration. Each unit in a daisy-chain configuration must be added to the VMX300(-E), and then configured with the appropriate settings. Note that the recommended baud rate for communication between VMX300(-E) and the CM9760-ALM is 19200. You must set this baud rate on the Communications tab when you configure the CM9760-ALM device in the VMX300(-E). (Refer to the VMX300(-E) Server Configuration Manual for instructions.)

b.Change the CM9760-ALM settings to the following recommended settings for VMX300(-E) communication: RS-232, 19200 baud, no parity, 8 data bits, 1 stop bit. (Refer to the CM9760-ALM Installation/Operation manual for instructions.)

38

C1552M-C (7/07)

Image 42
Contents Addendum Rear ViewHow to Connect a Single Monitor to a VMX300-E Workstation VMX300-E Monitor OutputsVMX300-E Analog Video Inputs Model WorkstationsISO9001 Installation Manual Page Contents List of Illustrations List of TablesImportant Safety Instructions Regulatory Notices Video Quality CautionDescription Models VMX300 ModelsVMX300-E Models VMX300-E-CL-0 ClientVMX300E-B Backup Server Compatible ProductsDocumentation Resources Matrix Switchers Typical ApplicationsPelco Ascii Switchers Coaxitron and Fixed Camera Transmission DX8000 and DX9000 Series Dvrs Looping Camera OutputsConnecting a DVR Method Pelconet Transmission Systems NetworkNetworkip Example 3 of a PelcoNet Configuration NVR300 Network Video Recorder Sample VMX300-E System with the NVR300Installation Parts ListUSER-SUPPLIED Parts Rack Mount Installation MountingFront View Rear View VMX300-E Connections VMX300-E Connections to the NetworkVMX300-E Keyboard and Mouse Right VGA Monitor Video Input External Devices Direct Serial ConnectionInternet Protocol KBD300A Keyboard KBD300A Direct Serial ConnectionNetwork Keyboard SPECTRA/ESPRIT Control Connections Communications tab, Connection Type Select Direct SerialCM6700 Switcher Connect Ground on ONE END onlyCM6800 Switcher CM6800 Port Programming Alternate CM6800 Connection CM9700 Matrix Switching Systems Alternate CM9700 Connection CM9760-ALM Alarm Interface Unit CM9760-REL Relay Interface Unit RDA RDB RS-422 Reversed CableSerial Output Device IP-BASED DevicesPower Cables Changing the Port Settings of a VMX300-E COM Port AppendixSpecifications ELECTRICAL/ VideoPage Product Warranty and Return Information ISO9001