Pelco VMX300 installation manual Alternate CM9700 Connection

Page 41

Alternate CM9700 Connection

If you control your CM9700 system with CM9760-MGR software, you can use the RS-232 COM port on the CC1 for the VMX300(-E) connection. Complete the following steps to connect the VMX300(-E) to the CC1:

1.Using a null modem cable (user-supplied), plug one end into one of the RS-232 ports (COM 1 or COM 2) on the VMX300(-E).

2.Plug the other end of the cable into the RS-232 COM 2 port on the CC1.

NULL MODEM CABLE

 

 

 

 

 

 

CM9700-CC1

PRINTER COM1 COM2

 

 

 

 

 

CM9700-CC1

 

 

OR

 

 

 

CM9740-CC1

 

 

 

CM9740-CC1

COM1

COM2

PRINTER LPT1

VGA

Figure 35. CM9700 RS-232 Connections

 

3.After installing system hardware, complete the following configuration steps (refer to the VMX300(-E) Server Configuration Manual for detailed instructions):

a.Add the Pelco P driver and the switcher to the VMX300(-E) server configuration, and select Direct Series as the connection type.

b.In the CM9760-MGR software, change the CC1 RS-232 COM 2 settings to match the VMX300(-E) RS-232 COM port settings: 9600 baud, no parity, 8 data bits, 1 stop bit. Designate the port as a keyboard (equipment number 100).

NOTE: If you use the Pelco ASCII driver in the VMX300(-E) server configuration, some of these settings will change (refer to the VMX300(-E) Server Configuration Manual for information on when and how to use the ASCII driver).

C1552M-C (7/07)

37

Image 41
Contents Rear View AddendumVMX300-E Monitor Outputs How to Connect a Single Monitor to a VMX300-E WorkstationModel Workstations VMX300-E Analog Video InputsISO9001 Installation Manual Page Contents List of Tables List of IllustrationsImportant Safety Instructions Video Quality Caution Regulatory NoticesDescription VMX300 Models ModelsVMX300-E-CL-0 Client VMX300-E ModelsDocumentation Resources VMX300E-B Backup ServerCompatible Products Typical Applications Matrix SwitchersPelco Ascii Switchers Coaxitron and Fixed Camera Transmission Looping Camera Outputs DX8000 and DX9000 Series DvrsConnecting a DVR Method Network Pelconet Transmission SystemsNetworkip Example 3 of a PelcoNet Configuration Sample VMX300-E System with the NVR300 NVR300 Network Video RecorderUSER-SUPPLIED Parts InstallationParts List Mounting Rack Mount InstallationFront View Rear View VMX300-E Keyboard and Mouse VMX300-E ConnectionsVMX300-E Connections to the Network Right VGA Monitor Video Input Direct Serial Connection External DevicesInternet Protocol KBD300A Direct Serial Connection KBD300A KeyboardNetwork Keyboard Communications tab, Connection Type Select Direct Serial SPECTRA/ESPRIT Control ConnectionsConnect Ground on ONE END only CM6700 SwitcherCM6800 Port Programming CM6800 SwitcherAlternate CM6800 Connection CM9700 Matrix Switching Systems Alternate CM9700 Connection CM9760-ALM Alarm Interface Unit RDA RDB RS-422 Reversed Cable CM9760-REL Relay Interface UnitIP-BASED Devices Serial Output DevicePower Cables Appendix Changing the Port Settings of a VMX300-E COM PortELECTRICAL/ Video SpecificationsPage Product Warranty and Return Information ISO9001