GLOBUG SOLO LIGHTING SYSTEM — MAINTENANCE
CAUTION - READ SAFETY GUIDELINES
Before performing any maintenance procedures, be sure to READ the lamp, balloon, and general safety guidelines in this manual. Failure to read and understand these safety guidelines could cause severe equipment damage and bodily harm.
Removing the Lamp/Balloon Assembly
1.Loosen the
CAUTION - BALLOON ZIPPER SAFETY
DO NOT use excessive force when zipping or unzipping the balloon. The possibility exists of the zipper tearing, which would make the balloon unusable.
2.Unzip the zipper (Figure 23) at the bottom of the balloon and roll the balloon envelope upwards to expose the lamp (Figure 24). Remove the lamp guard to gain access to the lamp. DO NOT use excessive force when unzipping the balloon.
Figure 22. Loosening the Balloon/Lamp
3.Disconnect the lamp power cable (Figure 6) and slide the balloon/lamp forward from the mast adapter stand. Place lamp/balloon assembly on a suitable work bench that is free of dirt, and sharp objects that could damage the balloon.
Removing the Lamp
1.Expose the balloon (Figure 23) by pulling down on the velcro tabs and unzip the protective cover as shown in Figure 19. Next, fold the protective cover into itself and
zip.
Figure 24. Removing the Lamp Guard
3.Push down and hold the lamp holder (spring loaded) away from the lamp (Figure 25). Unscrew the lamp (turn counterclockwise) from the lamp socket.
Figure 23. Exposing the Balloon | Figure 25. Removing the Lamp |
PAGE 20 — GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09)