Multiquip GB114BW manual GLOBUGSOLOLIGHTINGSYSTEM-WIRINGDIAGRAMS/NG20071 &ABOVE

Page 29

GLOBUGSOLOLIGHTINGSYSTEM—WIRINGDIAGRAM(S/NG20071 &ABOVE)

120 VAC, 60Hz

P1 INPUT BALLAST

POWER CABLE

 

BLK (LINE)

WHT (NEUTRAL)

 

 

GRN

GRN

 

CHASSIS

S1

OFF/ON

 

GND

 

SWITCH

 

 

 

 

 

ORANGE

NOT USED

 

 

PURPLE

 

 

 

 

BLACK

24µF

@480 VDC

CAPACITOR

C1

208 VAC

 

240 VAC

T1

277 VAC

 

TRANSFORMER

 

(BALLAST)

CAP

COM

120 VAC

RED/BLK

YEL YEL

BLK/YEL

 

BLK

SPLICE

 

 

FRONT VIEW

 

BALLAST

BLK

RECEPTACE

 

(FEMALE)

RED RED

 

 

J1

 

 

 

 

 

 

 

 

BLK 2

 

1 WHT

 

 

 

 

 

 

 

GRN

 

 

 

 

 

 

 

 

BLK

 

 

4

 

3 RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000 WATT

 

 

 

 

MALE

 

 

 

 

METAL HALIDE

 

 

 

 

 

 

 

 

 

LAMP

 

 

 

 

 

 

RED

 

RED (HOT)

 

 

 

 

 

 

 

 

 

 

 

 

DS1

 

 

 

 

 

 

WHT

 

WHT (NEUTRAL)

 

 

 

LAMP

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

GRN

 

BUZZER

 

S2

S3

(W1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

GND

 

 

 

MICRO-SWITCH

 

 

 

 

 

 

 

 

WITH SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

 

WHT

 

BLUE

 

 

 

FEMALE

 

 

RED

 

 

 

 

 

 

 

 

 

 

BLK

 

 

FAN

 

 

 

 

 

WHT

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

GRN

 

 

 

 

 

2

 

1

BLK

 

 

 

 

 

FRONT VIEW

 

BLK

 

 

BLK

M1

 

 

 

 

 

 

 

 

 

LAMP CABLE

4

P2

3

16 AWG.

 

 

 

 

 

 

MALE PLUG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 6. REFERENCE DESIGNATIONS

 

 

 

 

 

REF.

 

DESCRIPTION

PART NUMBER

REF.

DESCRIPTION

PART NUMBER

 

 

 

 

 

 

 

 

 

DESC.

 

 

DESC.

 

 

 

 

 

 

P1

Input Power Cable Assy.(Ballast)

A300066700

M1

Fan Motor Assy.

A300033500

 

 

 

 

J1

Ballast Output Receptacle

A400079400

B1

Buzzer Alarm Balloon

E000030100

 

 

 

 

P2

Lamp Fan Cable Assy. (Input)

A300105500

S1

ON/OFF Switch

A400037502

 

 

 

 

DS1

1000 Watt Metal Halide Lamp

E000009800

S2

Micro-Switch

1400150210

 

 

 

 

C1

24 µF Capacitor @ 480 VDC

19598

S3

Micro-Switch Cap

1400150410

 

 

 

 

T1

Ballast (Transformer)

A300033800

W1

Lamp Power Cable

A300083900

 

 

GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09) — PAGE 29

Image 29
Contents Model GB114BW Table of Contents Order via Fax Dealers Only Best Deal! Order via Internet Dealers Only„ Always know the location of the nearest Result in injury to yourself and others„ Never unplug the lamp’s AC power cable during operation „ Never attempt service on a running machine„ Always make sure the area above Globug Solo Lighting System Safety InformationLoading and Unloading Globug Solo Lighting System Safety InformationGloBug Solo DimensionsLamp Fan MotorDimensions Globug Solo Lighting System DimensionsBased on 360glare-free coverage Globugsololightingsystem -FLOODLIGHTFOOTCANDLE PlotFloodlight Footcandle Plot BAL120R-Reflector Globug Solo Lighting System Floodlight Footcandle PlotFloodlight Footcandle Plot BAL115D-Drum Shaped Degree coverageBalloon Envelopes Globug Solo Lighting System General InformationGlobug Solo Lighting System Components Globug Solo Lighting System Components Globug Solo Lighting System PRE-SETUP Mast Lock Lever Globug Solo Lighting System PRE-SETUPPower OFF/ON Switch on Position Place the power ON/OFF switch in the OFF positionHot Lamp Surface Globug Solo Lighting System ShutdownRemoving the Lamp Removing the Lamp/Balloon AssemblyZip Reconnect the power cables Globug Solo Lighting System MaintenanceInstalling a New Lamp Re-Installing the Lamp/Balloon AssemblyCable Disconnection Ballast Box RemovalBalloon/Lamp Placement Filter ReplacementGlobug Solo Lighting System Maintenance Periodic Check and Maintenance Globug Solo Lighting System -TROUBLESHOOTING Lamps Mast cannot be Globug Solo Lighting System -TROUBLESHOOTING MastGLOBUGSOLOLIGHTINGSYSTEM-WIRINGDIAGRAMS/NG20070&BELOW GLOBUGSOLOLIGHTINGSYSTEM-WIRINGDIAGRAMS/NG20071 &ABOVE Part NO. Column NO. ColumnQTY. Column Remarks ColumnBALLAST/TRANSFORMER Globug Solo Lighting System Suggested Spare PartsBulb Globug Solo Lighting System Nameplate and Decals Nameplate and Decals Decal Lamp Switch ON/OFFDecal Caution Cover Information Decal Caution Lamp Cover BuzzerBase Assy Globug Solo Lighting System Base AssySpacer Weight OUT, R LRubber OUT, R Washer M8Mast Assy Globug Solo Lighting System -MAST AssyGlobug Solo Lighting System Mast Assy Ballast Assy Globug Solo Ballast ASSY. S/N G20040 & belowIncludes Items W/ $ Case WireFrame Holder BallastGlobug Solo Ballast ASSY. S/N G20041 G20070 Globug Solo Ballast ASSY. S/N G20041 G20070 Globug Solo Ballast ASSY. S/N G20071 and Above Globug Solo Ballast ASSY. S/N G20071 and Above Switch AssyCable Lamp CP, Threaded Cable MAIN-GB5FAN BLOWER/LAMP Base Assy Globug Solo Lighting System FAN BLOWER/LAMP Base AssyMicro Switch Cover Cover WireMicro Switch Micro Switch CAP SensorBALLOON/LAMP Guard Assy Globug Solo Lighting System BALLOON/LAMP Guard AssyOptional GBBAL120GBBAL115D Plate CAPTerms and Conditions of Sale Parts Page HERE’S HOW to GET Help