Multiquip GB114BW manual „ Never attempt service on a running machine

Page 5

GLOBUGSOLOLIGHTINGSYSTEM—SAFETYiNFORMATION

LIGHTING SYSTEM SAFETY

DANGER

„ NEVER use lighting system in rain, snow or areas of high humidity that could generate electrical storms.

WARNING

„NEVER disconnect any emergency or safety devices. These devices are intended for operator safety. Disconnection of these devices can cause severe injury, bodily harm or even death. Disconnection of any of these devices will void all warranties.

CAUTION

„NEVER attempt service on a running machine.

NOTICE

„To prevent the lighting system from overturning, NEVER use in winds that exceed 22mph (10 m/s).

„The lighting system should only be used in temperatures between 23° to 104°F (-5° to 40° C). Failure to comply with these operating parameters could cause the lamp to malfunction and shorten the ballast life.

„ALWAYS keep the lighting system in proper running condition.

„Fix damage to lighting system and replace any broken parts immediately.

„ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

LAMP SAFETY

WARNING

„NEVER attempt to replace lamp with the power on. Always unplug the power cord from the generator or power source when changing the lamp.

„ALWAYS allow a sufficient amount of time for the lamp to cool before changing. The possibility exists of severe burns.

CAUTION

„NEVER use force when installing the lamp. Excessive force could cause the lamp to break, causing bodily harm.

NOTICE

„NEVER leave any grease or oil residue on lamp surface when replacing or removing lamp. This can create hot spots, reducing the service life of the lamp.

„ALWAYS make sure lamp surface is clean and dry.

„ALWAYS replace with MQ recommended type lamp. See parts section of this manual.

„If applicable, ALWAYS make sure the lamp guard is installed correctly. NEVER deform the lamp guard.

„NEVER unplug the lamp’s AC power cable during operation.

„ALWAYS have a trained technician to install and remove lamp or replace any damaged fixture wiring.

BALLOON SAFETY

WARNING

„To prevent serious burns, NEVER touch or unzip the balloon envelope when the

lamp is on.

CAUTION

„ALWAYS keep the balloon away from sharp objects and excessive amounts of heat.

NOTICE

„To prevent balloon deformation, NEVER use lighting system in strong winds.

„DO NOT place the balloon inside its protective cover until the lamp has had a sufficient amount of time to cool down. This will prevent the balloon’s nylon cover from being burned (touching the lamp surface).

„ALWAYS place the balloon inside its protective cover after each use. This will prolong the life of the balloon material, keeping it protected from harsh environmental elements.

„Replace balloon immediately if damaged. A damaged balloon will not inflate properly, and may become more damaged by touching the hot lamp surface.

„DO NOT use excessive force when zipping and unzipping the balloon. Be gentle with the zipper mechanism. If the zipper is broken, the balloon will become unusable.

GB114BW GLOBUG SOLO LIGHTING SYSTEM — OPERATION & PARTS MANUAL — REV. #5 (01/06/09) — PAGE 5

Image 5
Contents Model GB114BW Table of Contents Order via Fax Dealers Only Best Deal! Order via Internet Dealers Only„ Always know the location of the nearest Result in injury to yourself and others„ Never unplug the lamp’s AC power cable during operation „ Never attempt service on a running machine„ Always make sure the area above Globug Solo Lighting System Safety InformationLoading and Unloading Globug Solo Lighting System Safety InformationGloBug Solo DimensionsLamp Fan MotorDimensions Globug Solo Lighting System DimensionsBased on 360glare-free coverage Globugsololightingsystem -FLOODLIGHTFOOTCANDLE PlotFloodlight Footcandle Plot BAL120R-Reflector Globug Solo Lighting System Floodlight Footcandle PlotFloodlight Footcandle Plot BAL115D-Drum Shaped Degree coverageBalloon Envelopes Globug Solo Lighting System General InformationGlobug Solo Lighting System Components Globug Solo Lighting System Components Globug Solo Lighting System PRE-SETUP Mast Lock Lever Globug Solo Lighting System PRE-SETUPPower OFF/ON Switch on Position Place the power ON/OFF switch in the OFF positionHot Lamp Surface Globug Solo Lighting System ShutdownRemoving the Lamp Removing the Lamp/Balloon AssemblyZip Reconnect the power cables Globug Solo Lighting System MaintenanceInstalling a New Lamp Re-Installing the Lamp/Balloon AssemblyCable Disconnection Ballast Box RemovalBalloon/Lamp Placement Filter ReplacementGlobug Solo Lighting System Maintenance Periodic Check and Maintenance Globug Solo Lighting System -TROUBLESHOOTING Lamps Mast cannot be Globug Solo Lighting System -TROUBLESHOOTING MastGLOBUGSOLOLIGHTINGSYSTEM-WIRINGDIAGRAMS/NG20070&BELOW GLOBUGSOLOLIGHTINGSYSTEM-WIRINGDIAGRAMS/NG20071 &ABOVE Part NO. Column NO. ColumnQTY. Column Remarks ColumnBALLAST/TRANSFORMER Globug Solo Lighting System Suggested Spare PartsBulb Globug Solo Lighting System Nameplate and Decals Nameplate and Decals Decal Lamp Switch ON/OFFDecal Caution Cover Information Decal Caution Lamp Cover BuzzerBase Assy Globug Solo Lighting System Base AssySpacer Weight OUT, R LRubber OUT, R Washer M8Mast Assy Globug Solo Lighting System -MAST AssyGlobug Solo Lighting System Mast Assy Ballast Assy Globug Solo Ballast ASSY. S/N G20040 & belowIncludes Items W/ $ Case WireFrame Holder BallastGlobug Solo Ballast ASSY. S/N G20041 G20070 Globug Solo Ballast ASSY. S/N G20041 G20070 Globug Solo Ballast ASSY. S/N G20071 and Above Globug Solo Ballast ASSY. S/N G20071 and Above Switch AssyCable Lamp CP, Threaded Cable MAIN-GB5FAN BLOWER/LAMP Base Assy Globug Solo Lighting System FAN BLOWER/LAMP Base AssyMicro Switch Cover Cover WireMicro Switch Micro Switch CAP SensorBALLOON/LAMP Guard Assy Globug Solo Lighting System BALLOON/LAMP Guard AssyOptional GBBAL120GBBAL115D Plate CAPTerms and Conditions of Sale Parts Page HERE’S HOW to GET Help