Voltage Adjustment (2) |
11 |
| VP |
|
10 |
| NC |
|
9 |
| VSW |
|
8 |
| NC |
|
7 |
| VBW |
|
6 |
| NC |
|
|
|
VBW 、 VP Adjustment
Measuring VBW which is between TP329 and
Adjust VBW by VR3. (Tolerance:+/- 0.5 volt)
In case of no measuring land on the board, please refer pin assignments.
VR3 (VBW)
VR1 (VP)
5 | GND |
4 | GND |
3 | GND |
2 | NC |
1 |
TP327 (VP)
TP329 (VBW)
Measuring VP which is between TP327 and GND. Adjust VP by VR1. (Tolerance:+/- 1.5 volt)