JVC HR-A5U manual Other Functions, Checking tape position, Function settings

Page 11

– Other Functions –

Other Functions

Checking tape position

When you change the VCR operation

 

 

 

 

 

mode from the stop mode to fast forward

 

 

 

 

 

or rewind mode, or when you perform an

 

 

 

 

 

Index Search or Instant Review, the tape

B

+ +

+

 

E

position indicator appears.

 

 

The position of “q” in relation to “B”

 

 

 

 

 

(Beginning) or “E” (End) shows you where

 

 

 

 

 

you are on the tape.

 

 

 

 

 

Set “SUPERIMPOSE” to “ON”.

Changing display information

Each time you press DISPLAY, the display panel shows the channel number and the clock time alternatively.

You can change display in the stop, recording or recording pause mode, or during rewind/fast- forward high-speed search.

When “SUPERIMPOSE” is set to “ON” and DISPLAY on the Remote is pressed, time counter will appear on the TV screen. To reset the time counter, press C. RESET on the Remote.

CChange setting

Press OK or e. The default setting is bold in the following table. Press MENU to return to normal screen.

AUTO PICTURE ON/OFF

When this function is set to “ON”, this VCR checks the condition of the tape in use during playback, and compensates to provide the highest-possible playback pictures.

PICTURE CONTROL AUTO(NORM)/EDIT/SOFT/SHARP

This function helps you to adjust the playback picture quality according to your preference.

AUTO (NORM): Normally select this. Picture quality is adjusted automatically. When “AUTO PICTURE” is “OFF”, “NORM” will appear instead of “AUTO”.

EDIT: Minimizes picture degradation during editing (recording and playback).

SOFT: Reduces image coarseness when viewing overplayed tapes containing much noise.

SHARP: Clearer, sharper-edged picture when viewing images with much flat, same-colored surfaces such as cartoons.

NOTE:

Select “EDIT” when you are editing tapes. After you finish editing the tapes, select “AUTO”.

AUTO TIMER — ON/OFF

When this function is set to “ON”:

Timer warning display

A warning appears on the TV screen to tell you that the timer-recording is to start in 5 minutes if you are not in the timer recording standby mode at that time. Press TIMER to put the VCR into timer recording standby mode. To clear the display, press CANCEL on the Remote.

–WARNING–

TIMER RECORDING TO START SOON

(CANCEL)

The timer recording standby mode is automatically engaged when the VCR is turned off. It is temporarily canceled when the VCR is turned on. You do not have to press TIMER to engage or disengage the timer recording standby mode.

When this function is set to “OFF”:

You have to press TIMER to engage or disengage the timer recording standby mode.

SUPERIMPOSE ON/OFF

Function settings

You can use the other useful function settings on the Function Set screen.

When this function is set to “ON”, various VCR status information (on-screen display) appears on the screen.

NOTE:

When you use this VCR as the playback VCR for editing a tape, be sure to set this function to “OFF”; otherwise, the VCR status information (on-screen display) will be recorded on the edited

AAccess Main Menu screen, then

Function Set screen

Press MENU on the Remote. Press rt to move the highlight bar (arrow) to “FUNCTION SET”, then press OK or e.

BSelect Function

MAIN MENU

FUNCTION SET

TUNER SET

INITIAL SET

PRESS ( ,), THEN (OK)

PRESS (MENU) TO END

tape.

AUTO SP]EP TIMER — ON/OFF

When this function is set to “ON”, the VCR automatically switches to EP mode to allow complete recording if there is not enough tape to record the entire program while timer-recording in SP mode.

Press rt to move the highlight bar (arrow) to the function you want to set.

FUNCTION

 

 

 

PREVIOUS PAGE

 

 

AUTO PICTURE

ON

 

 

BLUE BACK

ON

 

PICTURE CONTROL

AUTO

 

 

2ND AUDIO RECORD

OFF

 

AUTO TIMER

OFF

 

AUDIO MONITOR

HI-FI

 

SUPERIMPOSE

ON

 

 

 

 

AUTO SP EP TIMER

OFF

 

 

 

 

VIDEO STABILIZER

OFF

 

 

 

 

NEXT PAGE

 

 

 

 

 

 

SELECT WITH ( , ) AND (OK)

 

SELECT WITH ( , ) AND (OK)

 

PRESS (MENU) TO END

 

 

 

PRESS (MENU) TO END

 

 

For Example, Recording a program of 140 minutes in length onto a 120-minute tape

Approximately 110 minutes

Approximately 30 minutes

SP mode

EP mode

 

 

NOTES:

If you have programed the VCR to timer-record 2 or more programs, do not use this function, but change the tape speed manually during timer programing.

There may be some noise and sound disturbance where the tape speed switches from SP to EP mode on the tape.

This function is not available during ITR (Instant Timer Recording), and will not work properly on the following tapes: T(ST)-30, T(ST)-60, T(ST)-90, and T(ST)-120.

Image 11
Contents For Customer Use Dear CustomerCleaning Power SourcesPower Cord Protection AccessoriesRear Panel How to use the RemoteVideo heads cleaning Front PanelAV Connection RemoteOn-screen display RF ConnectionPreparations Initial SettingsLanguage Setting Clock SettingSetting channels manually Manual Channel Set Tuner SettingSetting channels automatically Auto Channel Set Setting clock manually Manual Clock SetBasic Playback Playback FeaturesPlayback Basic Recording RecordingSpecifying recording length Instant Timer Recording ITR Timer RecordingRecording Features Express Timer ProgramingReengage timer recording standby mode Select program to modify Disengage timerAccess Program screen Cancel or change program settingChecking tape position Function settingsOther Functions Cable Box or DBS Receiver Brand Setting Multi-Brand Remote ControlTV Brand Setting Change code for VCR Set remote control code for RemoteCheck remote control code for VCR Editing SpecificationsFor Servicing Only in U.S.A HOW to Locate Your JVC Service CenterLimited Warranty Warranty Only in U.S.A