3 CONNECTIONS
3-2 Audio system connections
3 CONNECTIONS
3-3 Other connections
Audio output from a VCR, etc. |
| |||
DV |
|
| Analog audio (2 channels) | |
DV |
|
|
|
|
IN/OUT | COMPONENT |
|
| |
VIDEO | AUDIO |
| ||
LINE |
|
| CH 1/3 CH 2/4 |
|
Y/C |
|
| IN | PGZ01945 |
IN | IN | |||
| Y |
|
|
|
|
|
| OUT |
|
OUT |
|
| OUT |
|
|
|
|
| |
|
|
| MONITOR |
|
|
|
| OUT |
|
MONITOR |
|
| 1 REMOTE | 2 |
SYNC IN | TIME CODE | SPARE SERIAL |
| |
OUT |
| |||
|
| TIMER |
| DC 12V |
|
| REC | PLAY | |
|
|
|
OFF
Headphones
Mic
DV |
|
|
|
|
|
|
|
|
IN/OUT | COMPONENT |
|
|
|
|
|
| |
VIDEO |
| AUDIO |
|
|
| |||
LINE |
|
|
| CH 1/3 | CH 2/4 |
|
|
|
Y/C |
|
|
|
| IN |
| PGZ01945 |
|
IN |
| IN |
|
|
| |||
| Y |
|
|
|
|
|
|
|
|
|
|
| OUT |
|
|
|
|
OUT |
|
|
|
| OUT |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| MONITOR |
|
|
|
|
|
|
|
| OUT |
|
|
|
MONITOR |
|
|
|
| 1 REMOTE | 2 |
|
|
SYNC IN | TIME CODE | SPARE SERIAL |
|
|
|
| ||
OUT |
|
|
|
| ||||
|
| TIMER |
| 1 | 2 | 3 | DC412V | 5 |
|
| REC | PLAY | |||||
|
|
|
|
|
|
| ||
|
| OFF |
|
|
|
|
|
|
DV | Analog audio | Analog audio |
| (2 channels) | (monaural) |
Audio input to a VCR, etc. |
|
Connection with a monitor TV The audio output from the [AUDIO MONITOR OUT] connector is monaural. Use the front panel [AUDIO MONITOR] switch to select the audio channels you want to monitor. The selected audio channel is shown in the table below. Adjust the audio volume level on the monitor.
Headphones jack Audio can be monitored in stereo using the headphones. Use the front panel [AUDIO OUTPUT] switch to select the audio channels you want to monitor. The selected audio channel is shown in the table below. Adjust the audio volume level with the front panel [PHONES] control.
Inputs
5 Analog inputs Audio connectors (CH1/3, CH2/4) Analog input connectors are only provided for 2 channels. It is not possible to record 4 channels simultaneously. Audio input from each connector is normally recorded on the CH1 and CH2 channels. Recording on the CH3 and CH4 can be performed in the Audio Dubbing mode with the No. 245 <SAMPLING RATE> menu switch set to “32K”.
Monitor TV
Outputs |
|
|
|
|
|
| |||
5 Analog outputs |
|
|
| ||||||
Audio connectors (CH1/3, CH2/4) |
|
| |||||||
Analog output connectors are provided for 2 channels. For | |||||||||
MiniDV format, use the front panel [AUDIO OUTPUT] | |||||||||
switch to select for | |||||||||
channel is shown in the table below. |
|
| |||||||
5 Digital outputs |
|
|
| ||||||
Digital signals conforming to IEEE 1394 are output from the | |||||||||
[DV IN/OUT] connector. |
|
| |||||||
Relationship between [AUDIO OUTPUT] / [AUDIO MONITOR] | |||||||||
switch and audio output channel |
|
| |||||||
(During playback with 32 kHz sampling, audio dubbing, and DV | |||||||||
input with the 32 kHz sampling in the EE mode) |
| ||||||||
Regardless of setting of this switch, CH1/2 is selected for ordinary | |||||||||
recording, record pause and analog audio input in the EE mode. | |||||||||
CH3/4 is selected for audio dubbing in the Pause mode. |
| ||||||||
| AUDIO switch |
| Connector |
| |||||
MONITOR | OUTPUT | MONITOR OUT | AUDIO OUT | ||||||
CH1/3 | CH2/4 | ||||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
|
|
| CH1/2 |
| CH1 | CH1 | CH2 | ||
|
|
|
|
|
| ||||
L |
|
| MIX |
|
| CH1/3 | CH1/3 | CH2/4 | |
|
|
|
| ||||||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
Remote connector |
| |||
Connect a remote controller to the appropriate connector | ||||
(three types are available). |
| |||
Type of connector | Connectable remote | |||
1 |
|
| controller | |
2 | [SERIAL] connector | |||
3 | [REMOTE1] connector | |||
|
| [REMOTE2] connector | ||
|
|
|
|
|
|
| Note: |
|
|
•Before connecting the
Power sockets
2 types of power supply are available (AC, DC). DC4power supply socket Connect DC 12 V. AC5power supply socket Connect AC 120 V (U MODEL), AC 220 – 240 V (E MODEL).
5 Selection of battery type Set the menu switch according to the type of battery that will be used.
* If the setting does not correspond to the battery type, the battery remaining time and battery alarm will not be correctly displayed.
Note:
• Do not use this unit continuously when the battery indicator is displayed. The unit may not operate properly. Remove the battery to avoid over- discharge.
For audio dubbing, refer to “Audio dubbing” on page 24. 5 Digital inputs Digital signals conforming to IEEE 1394 can be input to the [DV IN/OUT] connector. In this case, the audio recording level cannot be adjusted. When audio signals are input to the [DV IN/OUT] connector, some noise will occur at the point where recording ends. To reduce this noise during playback, set the No. 214 <V. FADE> menu switch to “ON”. 5 Mic input jack Connect a monaural microphone. The same audio is
MIX
CH3/4 CH1/2
MIX
CH3/4 CH1/2
CH3 | CH3 | CH4 |
CH1/2 | CH1 | CH2 |
CH1/2/3/4 | CH1/3 | CH2/4 |
CH3/4 | CH3 | CH4 |
CH2 | CH1 | CH2 |
See “396 BATTERY SELECT” on page 19.
•Used battery
The following batteries can be used with this unit.
•Flat shape type
•Anton Bauer Inc. : Trimpack 13 and 14 series
| Pro Pac 13 and 14 series |
• IDX Corporation : |
recorded on both channels.
R |
| MIX |
| CH2/4 | CH1/3 | CH2/4 |
|
|
|
|
|
| |
|
| CH3/4 |
| CH4 | CH3 | CH4 |
|
|
| ||||
|
|
|
|
|
|
12 | 13 |