Continental Automated Buildings Association 6002 Chapter Specifications, Remote Channels

Page 23

EdgeAccess® Universal Chassis System

Chapter 6

Specifications

6.1Single Mode Specifications

6.1.1 Local Channels

Data Rate:

Speed transparent

Protocols:

All, no limitation

Fiber:

Single mode (SMF)

Optical Connector:

ST, FC/PC, or SC Duplex

 

APC connectors (special order)

6.1.2 Remote Channels

Composite Data Rate: Speed transparent

Protocols:

All, no limitation

Fiber:

Single mode (SMF)

Optical Connector:

ST, FC/PC, or SC Duplex

 

APC connectors (special order)

6.1.3 Physical

Dimensions:

 

Stand Alone:

1.72"H x 8.45"W x 11.50"D

 

(43 x 215 x 291mm)

Rack Mount:

8.5"H x 1.0"W x 9.75"D

 

(215.9 x 25 x 247.65mm)

Weight:

 

Stand Alone:

1.5 lb. (0.68kg)

Rack Mount:

1.2 lb. (0.54kg)

6.1.4 Environmental

Operating Temperature:

Stand Alone: -20° to 70° C

Rack Mount: 0° to 50° C

Operating Humidity: 10 to 95%, non-condensing

6002/6003/6004 WWDM Users Manual

6-1

Image 23
Contents EdgeAccess Universal Chassis System EdgeAccess Universal Chassis System Canoga Perkins Corporation Canoga Perkins Table of Contents List of Figures Overview Chapter General OverviewRack Mount 6002/3/4 Models Stand Alone 6002/3/4 ModelsInstalling Modules into a UCS Chassis Chapter Set-up and InstallationUnpacking and Installing the Stand Alone Models Unpacking and Installing the Rack Mount ModelsFiber Optic Cabling Cleaning Fiber Optic ConnectorsConnecting Fiber Optic Cables CablingMeasuring Remote Transmitter Output Power Checking Optical Power LevelsMeasuring Local Transmitter Output Power Measuring Receiver Input PowerWwdm Application Chapter User OperationExample for a Model 6002, 1310/1550 Wwdm Operation of the Stand Alone ModelsCIM Operation of the Rack Mount ModelsThis Page is Intentionally Left Blank Universal Chassis System Software Chapter Software InteractionChassis Management Screen Showing Inserted Modules Accessing the Select Module Menu Naming the WDM module in a Chassis ConfigurationEntering a Descriptive Name for the 6002 Module Troubleshooting Guide Chapter Troubleshooting and MaintenanceTroubleshooting Fiber Optic Cables Maintenance Physical Chapter SpecificationsSingle Mode Specifications Local Channels Remote ChannelsUnidirectional Two Channel WDM Wwdm Model SpecificationsUnidirectional Four Channel Wwdm Unidirectional Three Channel WwdmThis Page is Intentionally Left Blank Cable Products Appendix a WarrantyWarranty Electronic Products Return Policy Customer Service Department Repair WarrantyLimitations Customer Service Department Extended Warranty Policy