Continental Automated Buildings Association 6002 user manual Table of Contents

Page 5

EdgeAccess® Universal Chassis System

Table of Contents

Chapter 1 General Overview

1-1

1.1

Overview

1-1

1.2

Stand Alone 6002/3/4 Models

1-2

1.3

Rack Mount 6002/3/4 Models

1-2

Chapter 2 Set-up and Installation

2-1

2.1

Unpacking and Installing the Stand Alone Models

2-1

2.2

Unpacking and Installing the Rack Mount Models

2-1

2.3

Installing Modules into a UCS Chassis

2-1

2.4

Cabling

2-2

2.4.1

Fiber Optic Cabling

2-2

2.4.2

Cleaning Fiber Optic Connectors

2-2

2.4.3

Connecting Fiber Optic Cables

2-2

2.4.4

Checking Optical Power Levels

2-3

2.4.5

Measuring Remote Transmitter Output Power

2-3

2.4.6

Measuring Receiver Input Power

2-4

Chapter 3 User Operation

3-1

3.1

WWDM Application

3-1

3.2

Operation of the Stand Alone Models

3-2

3.3

Operation of the Rack Mount Models

3-3

Chapter 4 Software Interaction

4-1

4.1

Universal Chassis System Software

4-1

4.2

Naming the WDM module in a Chassis Configuration

4-3

Chapter 5 Troubleshooting and Maintenance

5-1

5.1

Troubleshooting Fiber Optic Cables

5-1

5.2

Troubleshooting Guide

5-1

5.3

Maintenance

5-2

Chapter 6 Specifications

6-1

6.1

Single Mode Specifications

6-1

6.1.1

Local Channels

6-1

6.1.2

Remote Channels

6-1

6.1.3

Physical

6-1

6.1.4

Environmental

6-1

6.2

WWDM Model Specifications

6-2

6.2.1

Unidirectional Two Channel WDM

6-2

6.2.2

Unidirectional Three Channel WWDM

6-3

6.2.3

Unidirectional Four Channel WWDM

6-3

6002/6003/6004 WWDM Users Manual

v

Image 5
Contents EdgeAccess Universal Chassis System EdgeAccess Universal Chassis System Canoga Perkins Corporation Canoga Perkins Table of Contents List of Figures Overview Chapter General OverviewRack Mount 6002/3/4 Models Stand Alone 6002/3/4 ModelsUnpacking and Installing the Stand Alone Models Chapter Set-up and InstallationUnpacking and Installing the Rack Mount Models Installing Modules into a UCS ChassisConnecting Fiber Optic Cables Cleaning Fiber Optic ConnectorsCabling Fiber Optic CablingMeasuring Remote Transmitter Output Power Checking Optical Power LevelsMeasuring Local Transmitter Output Power Measuring Receiver Input PowerWwdm Application Chapter User OperationExample for a Model 6002, 1310/1550 Wwdm Operation of the Stand Alone ModelsCIM Operation of the Rack Mount ModelsThis Page is Intentionally Left Blank Universal Chassis System Software Chapter Software InteractionChassis Management Screen Showing Inserted Modules Accessing the Select Module Menu Naming the WDM module in a Chassis ConfigurationEntering a Descriptive Name for the 6002 Module Troubleshooting Guide Chapter Troubleshooting and MaintenanceTroubleshooting Fiber Optic Cables Maintenance Single Mode Specifications Local Channels Chapter SpecificationsRemote Channels PhysicalUnidirectional Two Channel WDM Wwdm Model SpecificationsUnidirectional Four Channel Wwdm Unidirectional Three Channel WwdmThis Page is Intentionally Left Blank Cable Products Appendix a WarrantyWarranty Electronic Products Return Policy Customer Service Department Repair WarrantyLimitations Customer Service Department Extended Warranty Policy