E L A N H O M E  | S Y S T E M S  | V883 INSTALLATION MANUAL  | |||
6. Troubleshooting | 
  | 
  | |||
General | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | 
  | SYMPTOM | 
  | CAUSE | SOLUTION | 
  | 
  | No power up. | 
  | 1. No AC power.  | Connect Power Cord to AC outlet.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Check AC circuit breaker.  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 1. Blown fuse.  | Replace fuse w/ T0.4AL type fuse  | 
  | 
  | 
  | 
  | 
  | (T0.2AL for 240V version).  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
IR Control
SYMPTOM  | CAUSE  | SOLUTION  | |
No source or zone selected  | 1. IR controller not programmed.  | Program IR controller.  | |
from IR controller (keypad,  | 
  | 
  | |
  | 
  | ||
2. IR signal path wiring bad.  | Verify IR signal path wiring.  | ||
IR LED does NOT flash  | 
  | Check keypads, IR sensors, IR  | |
when button pressed.  | 
  | distribution blocks, V883 IR Input  | |
  | 
  | jack, IR emitters, etc.  | |
  | 
  | 
  | |
No source or zone selected  | 1. Incorrect IR commands  | Verify/correct IR programming.  | |
from IR controller (keypad,  | programmed (not V883  | 
  | |
commands).  | 
  | ||
IR LED DOES flash when  | 2. UNIT ID DIP switches incorrect.  | Verify/correct DIP switches.  | |
button pressed.  | |||
  | 
  | ||
  | 
  | 
  | |
Intermittant or no source or  | IR flooding.  | Check IR receivers or V883 front  | |
zone control from IR control-  | 
  | IR sensor for ambient light or  | |
ler (keypad,   | 
  | plasma TV flooding.  | |
remote, etc.). IR LED flickers  | 
  | 
  | |
or is lit constantly.  | 
  | 
  | |
  | 
  | 
  | |
Incorrect source and/or zone  | Incorrect V883 IR commands  | Verify/correct IR programming.  | |
selected.  | programmed.  | 
  | |
  | 
  | 
  | 
© ELAN Home Systems 2006 • All rights reserved.  | Page 23  |