-Adjust sequence
A Press the PIP key of the ADJ remote controller. (This PIP key is hot key to enter the VCOM adjusting mode)
(Or After enter Service Mode by pushing “ADJ” key, then Enter
A As pushing the right or the left button on the remote controller, And find the
(If there is no flicker at default value, Press the exit key and finish the VCOM adjustment.)
A Push the OK key to store value. Then the message “Saving OK” is pop.
A Press the exit key to finish VCOM adjustment.
[Visual Adjust and control the Voltage level]
3.6.Model name & serial number download
(1)Model name & Serial number D/L
A Press “Power on” key of service remocon.(Baud rate : 115200 bps)
A Connect RS232 Signal Cable to
A Must check the serial number at Instart menu.
(2)Method & notice
A.Serial number D/L is using of scan equipment.
B.Setting of scan equipment operated by Manufacturing Technology Group.
C.Serial number D/L must be conformed when it is produced in production line, because serial number D/L is mandatory by
*Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or service man, sometimes model name or serial number is initialized.(Not always)
There is impossible to download by bar code scan, so It need Manual download.
a.Press the ‘instart’ key of ADJ remote control.
b.Go to the menu ‘5.Model Number D/L’ like below photo.
c.Input the Factory model name(ex
d. Check the model name Instart menu
e. Check the Diagnostics (DTV country only)
3.7.CI+ Key Download method
(1)Download Procedure
1)Press "Power on" button of a service R/C.(Baud rate : 115200 bps)
2)Connect
3)Write CI+ Key through
4)Check whether the key was downloaded or not at ‘In Start’ menu. (Refer to below).
=> Check the Download to CI+ Key value in LGset.
1.check the method of CI+ Key value
a.check the method on Instart menu
b.check the method of RS232C Command
1)into the main ass’y mode (RS232 : aa 00 00)
CMD 1 | CMD 2 |
| Data 0 | |
|
|
|
|
|
A | A | 0 |
| 0 |
|
|
|
|
|
2)check the key download for transmitted command (RS232 : ci 00 10)
CMD 1 | CMD 2 |
| Data 0 | |
|
|
|
|
|
C | I | 1 |
| 0 |
|
|
|
|
|
3)result value
-normally status for download : OKx
-abnormally status for download : NGx
2.Check the method of CI+ Key value (RS232)
1)into the main ass’y mode (RS232 : aa 00 00)
CMD 1 | CMD 2 |
| Data 0 | |
|
|
|
|
|
A | A | 0 |
| 0 |
|
|
|
|
|
2)Check the method of CI+ key by command (RS232 : ci 00 20)
CMD 1 | CMD 2 |
| Data 0 | |
|
|
|
|
|
C | I | 2 |
| 0 |
|
|
|
|
|
3)Result value
i 01 OK 1d1852d21c1ed5dcx
CI+ key Value
Copyright © 2010 LG Electronics. Inc. All rights reserved. | - 9 - | LGE Internal Use Only |